Yıl: 2021 Cilt: 25 Sayı: 2 Sayfa Aralığı: 563 - 570 Metin Dili: İngilizce DOI: 10.16984/saufenbilder.884517 İndeks Tarihi: 29-07-2022

Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building

Öz:
Tall buildings have the ability to produce wind energy, having been exposed to relatively highairflow speeds at a far distance from ground levels. However, with the introduction of windenergy into urban areas, there are many concerns. These include especially environmental noiseimpacts since the wind turbines will be located in dense urban areas where tall buildings aremostly located. Therefore, this increasing use of wind energy in the built environment has ledto the publication of up-to-date regulations that limit noise levels for wind farms in manyEuropean countries. At this point, the following three aspects should be considered for noiseemission: the noise source, the distance from the source, and the sound pressure level of thenoise source. The choice of wind turbines for urban environments should, therefore, becompatible with low noise levels. In addition, careful positioning of turbines is also important(avoid locations where wind conditions are unfavorable, avoid sensitive places, i.e. areas atwhich noise levels must be low). It was necessary to calculate the noise in strong winds becausethe noise from a wind turbine rises with wind velocity. For the measurement of noise emittedfrom the wind turbine, two potential solutions were proposed until now; either it could bemeasured in a wind tunnel or it could be measured in the natural wind outside. However, in theearly design stage, these types of measurement methods are mostly not preferable due to highfinancial requirements and long measurement processes. Hence, in this study, wind turbinenoise is simulated via software. A case study of a tall mixed-use tower is chosen and theenvironmental noise distribution due to the wind turbine located on the roof of the tower issimulated. The results may provide an important guideline for architects looking for anacoustically comfortable way to integrate wind turbines into their buildings in the early designstage.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • [1] “GWEC Global Wind Report 9 April 2014,” www.gwec.net. [Online]. Available: http://www.gwec.net/publications/globalwind-report-2/global-wind-report-2014- annual-market-update. [Accessed: 20-Feb2021].
  • [2] T. Stathopoulos and B. Blocken, “Pedestrian Wind Environment Around Tall Buildings,” Advanced Environmental Wind Engineering, pp. 101–127, 2016.
  • [3] J. F. Manwell, J. G. McGowan, and A. L. Rogers, Wind energy explained: theory, design and application. Chichester: John Wiley & Sons, 2011.
  • [4] S. Stankovic, N. Campbell, and A. Harries, Urban wind energy. London: Routledge, 2015.
  • [5] S. Wagner, R. Bareiss, and G. Guidati, Wind turbine noise. Berlin: Springer, 2012.
  • [6] “Keel profiles, blunt trailing edge and xfoil/XFLR5,” Boat Design Net. [Online]. Available: http://www.boatdesign.net/forums/hydrody namics-aerodynamics/keel-profiles-blunttrailing-edge-xfoil-xflr5-40889.html. [Accessed: 20-Feb-2021].
  • [7] “NREL Collaborates to Improve Wind Turbine Technology (Fact Sheet),” 2012.
  • [8] “Catalogs,” V90-3.0 MW® - Vestas - Page - PDF Catalogs | Documentation | Brochures. [Online]. Available: https://pdf.archiexpo.com/pdf/vestas/v90- 30-mw/88087-281441-_7.html. [Accessed: 20-Feb-2021].
APA karadag i, Kuruçay E (2021). Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. , 563 - 570. 10.16984/saufenbilder.884517
Chicago karadag ilker,Kuruçay Emre Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. (2021): 563 - 570. 10.16984/saufenbilder.884517
MLA karadag ilker,Kuruçay Emre Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. , 2021, ss.563 - 570. 10.16984/saufenbilder.884517
AMA karadag i,Kuruçay E Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. . 2021; 563 - 570. 10.16984/saufenbilder.884517
Vancouver karadag i,Kuruçay E Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. . 2021; 563 - 570. 10.16984/saufenbilder.884517
IEEE karadag i,Kuruçay E "Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building." , ss.563 - 570, 2021. 10.16984/saufenbilder.884517
ISNAD karadag, ilker - Kuruçay, Emre. "Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building". (2021), 563-570. https://doi.org/10.16984/saufenbilder.884517
APA karadag i, Kuruçay E (2021). Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 25(2), 563 - 570. 10.16984/saufenbilder.884517
Chicago karadag ilker,Kuruçay Emre Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi 25, no.2 (2021): 563 - 570. 10.16984/saufenbilder.884517
MLA karadag ilker,Kuruçay Emre Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi, vol.25, no.2, 2021, ss.563 - 570. 10.16984/saufenbilder.884517
AMA karadag i,Kuruçay E Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2021; 25(2): 563 - 570. 10.16984/saufenbilder.884517
Vancouver karadag i,Kuruçay E Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building. Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2021; 25(2): 563 - 570. 10.16984/saufenbilder.884517
IEEE karadag i,Kuruçay E "Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building." Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 25, ss.563 - 570, 2021. 10.16984/saufenbilder.884517
ISNAD karadag, ilker - Kuruçay, Emre. "Noise Emission from Building Integrated Wind Turbines: A Case Study of a Tall Building". Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi 25/2 (2021), 563-570. https://doi.org/10.16984/saufenbilder.884517