Yıl: 2023 Cilt: 53 Sayı: 6 Sayfa Aralığı: 1799 - 1806 Metin Dili: İngilizce DOI: 10.55730/1300-0144.5750 İndeks Tarihi: 18-01-2024

Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?

Öz:
Background/aim: Despite advancements in valve technology and increased clinical experience, complications related to conduction defects after transcatheter aortic valve implantation (TAVR) have not improved as rapidly as expected. In this study, we aimed to predict the development of complete atrioventricular (AV) block and bundle branch block during and after the TAVR procedure and to investigate any changes in the cardiac conduction system before and after the procedure using electrophysiological study. Materials and methods: A total of 30 patients who were scheduled for TAVR at our cardiovascular council were planned to be included in the study. TAVR was performed on patients at Erciyes University Medical Faculty Hospital as a single center between May 2019 and August 2020 Diagnostic electrophysiological study was performed before the TAVR procedure and after its completion. Changes in the cardiac conduction system during the preprocedure, intra-procedure, and postprocedure periods were recorded. Results: Significant increases in baseline cycle length, atrial-His (AH) interval, his-ventricular (HV) interval and atrioventricular (AV) distance were observed before and after the TAVR procedure (p = 0.039, p < 0.001, p = 0.018, p < 0.001, respectively). During the TAVR procedure, the preprocedural HV interval was longer in patients who developed AV block and bundle branch block compared to those who did not and this difference was statistically significant (p = 0.024). ROC curve analysis revealed that a TAVR preprocedure HV value >59.5 ms had 86% specificity and 75% sensitivity in detecting AV block and bundle branch block (AUC = 0.83, 95% CI: 0.664–0.996, p = 0.013). The preprocedure HV distance was 98 ± 10.55ms in the group with permanent pacemaker implantation and the mean value in the group without permanent pacemaker implantation was 66.27 ± 15.55 ms, showing a borderline significant difference (p = 0.049). Conclusion: The prolongation of HV interval in patients with AV block and bundle branch block suggests that the block predominantly occurs at the infra-hisian level. Patients with longer preprocedural HV intervals should be closely monitored for the need for permanent pacemaker implantation after the TAVR procedure.
Anahtar Kelime: Transcatheter aortic valve implantation bundle branch block AV block atrial-his interval

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002; 106 (24): 3006-3008. https://doi: 10.1161/01.cir.0000047200.36165.b8
  • 2. Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP 3rd et al. 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2017; 135 (25): e1159-e1195. https://doi: 10.1161/CIR.0000000000000503
  • 3. Popma JJ, Deeb GM, Yakubov SJ, Mumtaz M, Gada H et al. Evolut Low Risk Trial Investigators. Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients. New England Journal of Medicine. 2019; 380 (18): 1706-1715. https ://doi: 10.1056/NEJMoa1816885
  • 4. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK et al. PARTNER 3 Investigators. Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. New England Journal of Medicine. 2019; 380 (18): 1695-1705. https://doi: 10.1056/NEJMoa1814052
  • 5. Cesna S, De Backer O, Søndergaard L. Rapid adoption of transcatheter aortic valve replacement in intermediate- and high-risk patients to treat severe aortic valve stenosis. Journal of Thoracic Disease. 2017; 9 (6): 1432-1436. https :// doi: 10.21037/jtd.2017.05.67
  • 6. Moreno R, Dobarro D, López de Sá E, Prieto M, Morales C et al. Cause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study. Circulation. 2009; 120 (5): e29-30. https ://doi: 10.1161/ CIRCULATIONAHA.109.849281
  • 7. Gaede L, Kim WK, Liebetrau C, Dörr O, Sperzel J et al. Pacemaker implantation after TAVI: predictors of AV block persistence. Clinical Research in Cardiology. 2018; 107 (1): 60- 69. https :// doi: 10.1007/s00392-017-1158-2
  • 8. Siontis GCM, Jüni P, Pilgrim T, Stortecky S, BüllesfeldL et al. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: A meta- analysis. Journal of the American College of Cardiology. 2014; 64: 129–140. https :// doi: 10.1016/j.jacc.2014.04.033
  • 9. De Torres-Alba F, Kaleschke G, Diller GP, Vormbrock J, Orwat S et al. Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation: The Critical Role of Valve Implantation Height. Journal of the American College of Cardiology Cardiovasc Interventions. 2016; 9 (8): 805-813. https ://doi: 10.1016/j. jcin.2015.12.023
  • 10. Benedict M.Glover PB. Klinik Kardiyak Elektrofizyoloji El Kitabı. Prof. Dr. Onur Akpınar PDMK, editor. Çukurova Adana 2018. 68-75 p
  • 11. Piazza N, Onuma Y, Jesserun E, Kint PP, Maugenest AM et al. Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve. Journal of the American College of Cardiology Cardiovasc Interventions. 2008; 1 (3): 310-316. https ://doi: 10.1016/j.jcin.2008.04.007
  • 12. Berry C, Asgar A, Lamarche Y, Marcheix B, Couture P et al. Novel therapeutic aspects of percutaneous aortic valve replacement with the 21F CoreValveRevalving System. Catheterization and Cardiovascular Interventions. 2007; 70 (4): 610-616. https ://doi: 10.1002/ccd.21282
  • 13. Marcheix B, Lamarche Y, Berry C, Asgar A, Laborde JC et al. Surgical aspects of endovascular retrograde implantation of the aortic CoreValvebioprosthesis in high- risk older patients with severe symptomatic aortic stenosis. Journal of Thoracic and Cardiovascular Surgery. 2007; 134 (5): 1150-1156. https ://doi: 10.1016/j.jtcvs.2007.07.031
  • 14. Avanzas P, Muñoz-García AJ, Segura J, Pan M, Alonso- Briales JH et al. Percutaneous implantation of the CoreValve self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Revista Española de Cardiología. 2010; 63 (2): 141-148. https :// doi: 10.1016/s1885- 5857(10)70031-1
  • 15. Grube E, Buellesfeld L, Mueller R, Sauren B, Zickmann B et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValveRevalving system. Circulation Cardiovascular Interventions. 2008; 1 (3): 167-175. https ://doi: 10.1161/ CIRCINTERVENTIONS.108.819839
  • 16. Bleiziffer S, Ruge H, Hörer J, Hutter A, Geisbüsch S et al. Predictors for new-onset complete heart block after transcatheter aortic valve implantation. Journal of the American College of Cardiology Cardiovasc Interventions. 2010; 3 (5): 524-530. doi: 10.1016/j.jcin.2010.01.017
  • 17. Siontis GC, Jüni P, Pilgrim T, Stortecky S, BüllesfeldL et al. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. Journal of the American College of Cardiology. 2014; 64 (2): 129-140. https :// doi: 10.1016/j.jacc.2014.04.033
  • 18. Rubín JM, Avanzas P, del Valle R, Renilla A, Ríos E et al. Atrioventricular conduction disturbance characterization in transcatheter aortic valve implantation with the CoreValve prosthesis. Circulation Cardiovascular Interventions. 2011; 4 (3): 280-286. https :// doi: 10.1161/ CIRCINTERVENTIONS.111.961649
APA Cetinkaya Z, elcik d, Kelesoglu S, cesur b, Yasan M, karabıyık u, Bingol B, kalay n, TOPSAKAL R, TUNÇAY A, Dogan A, Inanc M (2023). Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. , 1799 - 1806. 10.55730/1300-0144.5750
Chicago Cetinkaya Zeki,elcik deniz,Kelesoglu Saban,cesur burak,Yasan Mustafa,karabıyık uğur,Bingol Bilge,kalay nihat,TOPSAKAL RAMAZAN,TUNÇAY AYDIN,Dogan Ali,Inanc Mehmet Tugrul Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. (2023): 1799 - 1806. 10.55730/1300-0144.5750
MLA Cetinkaya Zeki,elcik deniz,Kelesoglu Saban,cesur burak,Yasan Mustafa,karabıyık uğur,Bingol Bilge,kalay nihat,TOPSAKAL RAMAZAN,TUNÇAY AYDIN,Dogan Ali,Inanc Mehmet Tugrul Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. , 2023, ss.1799 - 1806. 10.55730/1300-0144.5750
AMA Cetinkaya Z,elcik d,Kelesoglu S,cesur b,Yasan M,karabıyık u,Bingol B,kalay n,TOPSAKAL R,TUNÇAY A,Dogan A,Inanc M Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. . 2023; 1799 - 1806. 10.55730/1300-0144.5750
Vancouver Cetinkaya Z,elcik d,Kelesoglu S,cesur b,Yasan M,karabıyık u,Bingol B,kalay n,TOPSAKAL R,TUNÇAY A,Dogan A,Inanc M Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. . 2023; 1799 - 1806. 10.55730/1300-0144.5750
IEEE Cetinkaya Z,elcik d,Kelesoglu S,cesur b,Yasan M,karabıyık u,Bingol B,kalay n,TOPSAKAL R,TUNÇAY A,Dogan A,Inanc M "Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?." , ss.1799 - 1806, 2023. 10.55730/1300-0144.5750
ISNAD Cetinkaya, Zeki vd. "Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?". (2023), 1799-1806. https://doi.org/10.55730/1300-0144.5750
APA Cetinkaya Z, elcik d, Kelesoglu S, cesur b, Yasan M, karabıyık u, Bingol B, kalay n, TOPSAKAL R, TUNÇAY A, Dogan A, Inanc M (2023). Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. Turkish Journal of Medical Sciences, 53(6), 1799 - 1806. 10.55730/1300-0144.5750
Chicago Cetinkaya Zeki,elcik deniz,Kelesoglu Saban,cesur burak,Yasan Mustafa,karabıyık uğur,Bingol Bilge,kalay nihat,TOPSAKAL RAMAZAN,TUNÇAY AYDIN,Dogan Ali,Inanc Mehmet Tugrul Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. Turkish Journal of Medical Sciences 53, no.6 (2023): 1799 - 1806. 10.55730/1300-0144.5750
MLA Cetinkaya Zeki,elcik deniz,Kelesoglu Saban,cesur burak,Yasan Mustafa,karabıyık uğur,Bingol Bilge,kalay nihat,TOPSAKAL RAMAZAN,TUNÇAY AYDIN,Dogan Ali,Inanc Mehmet Tugrul Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. Turkish Journal of Medical Sciences, vol.53, no.6, 2023, ss.1799 - 1806. 10.55730/1300-0144.5750
AMA Cetinkaya Z,elcik d,Kelesoglu S,cesur b,Yasan M,karabıyık u,Bingol B,kalay n,TOPSAKAL R,TUNÇAY A,Dogan A,Inanc M Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. Turkish Journal of Medical Sciences. 2023; 53(6): 1799 - 1806. 10.55730/1300-0144.5750
Vancouver Cetinkaya Z,elcik d,Kelesoglu S,cesur b,Yasan M,karabıyık u,Bingol B,kalay n,TOPSAKAL R,TUNÇAY A,Dogan A,Inanc M Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?. Turkish Journal of Medical Sciences. 2023; 53(6): 1799 - 1806. 10.55730/1300-0144.5750
IEEE Cetinkaya Z,elcik d,Kelesoglu S,cesur b,Yasan M,karabıyık u,Bingol B,kalay n,TOPSAKAL R,TUNÇAY A,Dogan A,Inanc M "Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?." Turkish Journal of Medical Sciences, 53, ss.1799 - 1806, 2023. 10.55730/1300-0144.5750
ISNAD Cetinkaya, Zeki vd. "Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?". Turkish Journal of Medical Sciences 53/6 (2023), 1799-1806. https://doi.org/10.55730/1300-0144.5750