Yıl: 2022 Cilt: 23 Sayı: 3 Sayfa Aralığı: 343 - 348 Metin Dili: İngilizce DOI: 10.4274/meandros.galenos.2022.15013 İndeks Tarihi: 27-10-2022

A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation

Öz:
Objective: The primary aim of the current study was to compare the centering ability and transportation of the Reciproc Blue system in curved root canals with and without prior glide path preparation, using cone beam computed tomography (CBCT). Additionally, the amount of time required for root canal instrumentation was also compared. Materials and Methods: Forty root canals of maxillary molar teeth with curvature angles 30°-40° were included in this in vitro study. All root canals were divided randomly into 2 experimental groups (n=20) as follows: group 1: the root canals were instrumented with a Reciproc Blue R25 instrument, and group 2: glide path was prepared with path-file and the root canals were instrumented with a Reciproc Blue R25 instrument. Working times with Reciproc Blue files were recorded for each group. All teeth were scanned with CBCT before and after instrumentation to evaluate the centering ability and transportation. The data were statistically analyzed using the Shapiro-Wilk test and t-test (p<0.05). Results: No significant difference was observed between the tested groups regarding the centering ability and transportation (p>0.05). The time required for instrumentation using Reciproc Blue after glide path preparation was statistically less than that without the glide path preparation group (p<0.001). Conclusion: In curved root canals, glide path preparation before instrumentation with the Reciproc Blue file had no effect on the centering ability and transportation. However, the amount of time required for root canal instrumentation with the Reciproc Blue files was significantly decreased when the files were used after the preparation of the glide path by path-files.
Anahtar Kelime:

Eğimli Kök Kanallarında Rehber Yol Oluşturularak Tek Eğeli Resiprokal Eğe ile Gerçekleştirilen Enstrümantasyonun CBCT ile Değerlendirilmesi

Öz:
Amaç: Bu çalışmanın birincil amacı, şekillendirme öncesi rehber yol hazırlanan ve hazırlanmayan eğimli kök kanallarında Reciproc Blue sisteminin merkezleme kabiliyetini ve meydana gelen transportasyon miktarını konik ışınlı bilgisayarlı tomografi (KIBT) kullanarak karşılaştırmaktır. Ayrıca her iki grupta kök kanal genişletme süreleri kıyaslanmıştır. Gereç ve Yöntemler: Bu in vitro çalışmaya kırk adet 30°-40° eğrilik açısına sahip kök kanalı dahil edildi. Tüm kök kanalları 2 deney grubuna ayrıldı: 1. grup: path- file ile rehber yol oluşturulduktan sonra Reciproc Blue kanal eğesi ile kök kanal şekillendirmesi gerçekleştirildi, 2. grup: Rehber yol oluşturmaksızın Reciproc Blue kanal eğesi ile kök kanal şekillendirmesi gerçekleştirildi. Her grup için Reciproc Blue eğeleri ile çalışma süreleri kaydedildi. Merkezleme kabiliyetini ve transportasyonu değerlendirmek için tüm dişler şekillendirmeden önce ve sonra KIBT ile tarandı. Veriler Shapiro-Wilk ve t-testi ile istatistiksel olarak analiz edildi. Bulgular: Merkezleme kabiliyeti ve transportasyon açısından test edilen gruplar arasında anlamlı bir fark tespit edilmemiştir (p>0,05). Rehber yol oluşturulan grupta Reciproc Blue kanal eğesi ile şekillendirme için gereken sürenin, rehber yol oluşturulmayan gruptan istatistiksel olarak daha az olduğu gözlenmiştir (p<0,001). Sonuç: Eğimli kök kanallarında, Reciproc Blue eğesi ile şekillendirme öncesinde rehber yol oluşturmanın merkezleme kabiliyeti ve transportasyon üzerinde hiçbir etkisi olmamıştır. Ancak, path-file ile rehber yol oluşturulduğunda Reciproc Blue eğesi ile kök kanalı içindeki çalışma süresi önemli ölçüde azalmıştır.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Yamamura B, Cox TC, Heddaya B, Flake NM, Johnson JD, Paranjpe A. Comparing canal transportation and centering ability of EndoSequence and Vortex rotary files by using microcomputed tomography. J Endod 2012; 38: 1121-5.
  • 2. Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G, et al. Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Endod 2009; 35: 408-12.
  • 3. West JD. The endodontic Glidepath: “Secret to rotary safety”. Dent Today 2010; 29: 86,88,90-3.
  • 4. Berutti E, Paolino DS, Chiandussi G, Alovisi M, Cantatore G, Castellucci A, et al. Root canal anatomy preservation of WaveOne reciprocating files with or without glide path. J Endod 2012; 38: 101-4.
  • 5. Cantatore G, Berutti E, Castellucci A. The pathfiles: a new series of rotary nickel titanium instruments for mechanical pre-flaring and creating the glide path. Oral Health 2010; 100: 66-8.
  • 6. Silva EJNL, Hecksher F, Antunes HDS, De-Deus G, Elias CN, Vieira VTL. Torsional fatigue resistance of blue-treated reciprocating instruments. J Endod 2018; 44: 1038-41.
  • 7. Hage W, Zogheib C, Bukiet F, Sfeir G, Khalil I, Gergi R, et al. Canal transportation and centring ability of reciproc and reciproc blue with or without use of glide path instruments: A CBCT Study. Eur Endod J 2020; 5: 118-22.
  • 8. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 1971; 32: 271-5.
  • 9. de Carvalho GM, Sponchiado Junior EC, Garrido AD, Lia RC, Garcia Lda F, Marques AA. Apical Transportation, Centering Ability, and Cleaning Effectiveness of Reciprocating Single-file System Associated with Different Glide Path Techniques. J Endod 2015; 41: 2045-9.
  • 10. De-Deus G, Cardoso ML, Belladonna FG, Cavalcante DM, Simões- Carvalho M, Souza EM, et al. Performance of Reciproc Blue R25 Instruments in Shaping the Canal Space without Glide Path. J Endod 2019; 45: 194-8.
  • 11. Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004; 30: 559-67.
  • 12. Backman CA, Oswald RJ, Pitts DL. A radiographic comparison of two root canal instrumentation techniques. J Endod 1992; 18: 19-24.
  • 13. Calhoun G, Montgomery S. The effects of four instrumentation techniques on root canal shape. J Endod 1988; 14: 273-7.
  • 14. Zanette F, Grazziotin-Soares R, Flores ME, Camargo Fontanella VR, Gavini G, Barletta FB. Apical root canal transportation and remaining dentin thickness associated with ProTaper Universal with and without PathFile. J Endod 2014; 40: 688-93.
  • 15. Elnaghy AM, Elsaka SE. Evaluation of root canal transportation, centering ratio, and remaining dentin thickness associated with ProTaper Next instruments with and without glide path. J Endod 2014; 40: 2053-6.
  • 16. Mouro-Netto C, Palo RM, Pinto LF, Mello-Moura ACV, Daltoe G, Wilhelmsen NSW. CT study of the performance of reciprocating and oscillatory motions in flattened root canal areas. Braz Oral Res 2015; 29: 1-6.
  • 17. Vorster M, van der Vyver PJ, Paleker F. Influence of Glide Path Preparation on the Canal Shaping Times of WaveOne Gold in Curved Mandibular Molar Canals. J Endod 2018; 44: 853-5.
  • 18. Hwang YH, Bae KS, Baek SH, Kum KY, Lee WC, Shon WJ, et al. Shaping ability of the conventional nickel-titanium and reciprocating nickel titanium file systems: a comparative study using micro-computed tomography. J Endod 2014; 40: 1186-9.
  • 19. Capar İD, Ertas H, Ok E, Arslan H, Ertas ET. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals. J Endod 2014; 40: 852-6.
  • 20. Roland DD, Andelin WE, Browning DF, Hsu GH, Torabinejad M. The effect of preflaring on the rates of separation for 0.04 taper nickel-titanium rotary instruments. J Endod 2002; 28: 543-5.
APA Miçooğulları Kurt S, SEREFOGLU B (2022). A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. , 343 - 348. 10.4274/meandros.galenos.2022.15013
Chicago Miçooğulları Kurt Seniha,SEREFOGLU BURCU A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. (2022): 343 - 348. 10.4274/meandros.galenos.2022.15013
MLA Miçooğulları Kurt Seniha,SEREFOGLU BURCU A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. , 2022, ss.343 - 348. 10.4274/meandros.galenos.2022.15013
AMA Miçooğulları Kurt S,SEREFOGLU B A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. . 2022; 343 - 348. 10.4274/meandros.galenos.2022.15013
Vancouver Miçooğulları Kurt S,SEREFOGLU B A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. . 2022; 343 - 348. 10.4274/meandros.galenos.2022.15013
IEEE Miçooğulları Kurt S,SEREFOGLU B "A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation." , ss.343 - 348, 2022. 10.4274/meandros.galenos.2022.15013
ISNAD Miçooğulları Kurt, Seniha - SEREFOGLU, BURCU. "A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation". (2022), 343-348. https://doi.org/10.4274/meandros.galenos.2022.15013
APA Miçooğulları Kurt S, SEREFOGLU B (2022). A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. Meandros Medical And Dental Journal, 23(3), 343 - 348. 10.4274/meandros.galenos.2022.15013
Chicago Miçooğulları Kurt Seniha,SEREFOGLU BURCU A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. Meandros Medical And Dental Journal 23, no.3 (2022): 343 - 348. 10.4274/meandros.galenos.2022.15013
MLA Miçooğulları Kurt Seniha,SEREFOGLU BURCU A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. Meandros Medical And Dental Journal, vol.23, no.3, 2022, ss.343 - 348. 10.4274/meandros.galenos.2022.15013
AMA Miçooğulları Kurt S,SEREFOGLU B A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. Meandros Medical And Dental Journal. 2022; 23(3): 343 - 348. 10.4274/meandros.galenos.2022.15013
Vancouver Miçooğulları Kurt S,SEREFOGLU B A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation. Meandros Medical And Dental Journal. 2022; 23(3): 343 - 348. 10.4274/meandros.galenos.2022.15013
IEEE Miçooğulları Kurt S,SEREFOGLU B "A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation." Meandros Medical And Dental Journal, 23, ss.343 - 348, 2022. 10.4274/meandros.galenos.2022.15013
ISNAD Miçooğulları Kurt, Seniha - SEREFOGLU, BURCU. "A CBCT-assisted Evaluation of Single Reciprocating File Instrumentation in Curved Root Canals with a Prior Glide Path Preparation". Meandros Medical And Dental Journal 23/3 (2022), 343-348. https://doi.org/10.4274/meandros.galenos.2022.15013