Yıl: 2022 Cilt: 52 Sayı: 4 Sayfa Aralığı: 965 - 974 Metin Dili: İngilizce DOI: 10.55730/1300-0144.5397 İndeks Tarihi: 14-12-2022

Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents

Öz:
Background/aim: This study aimed to evaluate the diameter and flow changes in the circle of Willis and side branches following the use of FDSs extending from the middle cerebral artery (MCA) to the internal carotid artery (ICA) for the treatment of aneurysms in the terminal segment of ICA, and the clinical results. Material and method: This study was conducted in a single center between January 2012 and April 2018 in patients with the anterior choroidal artery (AChoA), the posterior communicating artery (PComA), and the ICA terminal segment aneurysms treated with the FDSs. The changes in aneurysm size, arterial structures covered by the FDSs, and changes in the diameter and flow in arteries forming the circle of Willis were retrospectively analyzed. Results: Fourteen patients with a total of 25 aneurysms treated with FDSs extending from MCA to ICA were evaluated. The mean aneurysm fundus size was 5.14 mm (range 1.5–22 mm). Before treatment, the anterior communicating artery (AComA) was patent in all patients. Implanted FDSs covered the anterior cerebral artery (ACA) and AChoA in all patients (100%), nonhypoplasic PComA in two patients (14.28%), and the ophthalmic artery in nine (64.3%). The mean follow-up time was 36.78 ± 22.44 months. In follow- up, there was a decrease in the mean ipsilateral ACA A1 segment diameter from 1.99 ± 0.58 cm to 1.81 ± 0.31 cm (p = 0.01). The mean contralateral A1 segment diameter increased from 1.66 ± 0.48 cm to 1.93 ± 0.42 cm (p = 0.004). All aneurysms were totally occluded. Conclusion: If the AComA is patent, ipsilateral anterior circulation can be compensated through modifications in the contralateral ACA A1 segment in patients with ICA terminal segment aneurysms treated with FDSs extended from MCA to ICA and covering ACA. Although covering the anterior choroidal and lenticulostriate arteries by FDSs, ischemic complications may not occur frequently. Thus, this effective therapy can be applied more safely.
Anahtar Kelime: Flow-diverting stents circle of Willis intracranial aneurysm

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA et al. A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 2007; 38 (8): 2346-2352. doi: 10.1161/ STROKEAHA.106.479576
  • 2. Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA et al. A second- generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms. American Journal of Neuroradiology 2009; 30 (6): 1153-1158. doi: 10.3174/ajnr.A1530
  • 3. Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E et al. Curative Endovascular Reconstruction of Cerebral Aneurysms with the Pipeline Embolization Device: The Buenos Aires Experience. Neurosurgery 2009; 64(4): 632-642. doi: 10.1227/01.NEU.0000339109.98070.65
  • 4. Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke 2013; 44 (2): 442-447. doi: 10.1161/STROKEAHA.112.678151
  • 5. Briganti F, Napoli M, Tortora F, Solari D, Bergui M et al. Italian Multicenter Experience with Flow-Diverter Devices for Intracranial Unruptured Aneurysm Treatment with Periprocedural Complications-a Retrospective Data Analysis. Neuroradiology 2012; 54 (10): 1145-1152. doi: 10.1007/s00234- 012-1047-3
  • 6. Briganti F, Leone G, Marseglia M, Mariniello G, Caranci F et al. Endovascular treatment of cerebral aneurysms using flow- diverter devices: A systematic review. The Neuroradiology Journal 2015; 28 (4): 365-375. doi: 10.1177/1971400915602803
  • 7. Briganti F, Leone G, Ugga L, Marseglia M, Macera A et al. Mid- term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience. Journal of NeuroInterventional Surgery 2017; 9 (1): 70-76. doi: 10.1136/neurintsurg-2016-012502
  • 8. Strauss I, Maimon S. Silk Flow Diverter in the Treatment of Complex Intracranial Aneurysms: A Single-Center Experience with 60 Patients. Acta Neurochirurgica 2016; 158 (2): 247-254. doi: 10.1007/s00701-015-2644-9
  • 9. Kallmes DF, Brinjikji W, Cekirge S, Fiorella D, Hanel RA et al. Safety and efficacy of the Pipeline embolization device for treatment of intracranial aneurysms: a pooled analysis of 3 large studies. Journal of Neurosurgery 2017; 127 (4): 775-780. doi: 10.3171/2016.8.JNS16467
  • 10. Brinjikji W, Lanzino G, Cloft HJ, Siddiqui AH, Boccardi E et al. Risk Factors for Ischemic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the IntrePED Study. American Journal of Neuroradiology 2016; 37 (9): 1673-1678. doi: 10.3174/ajnr.A4807
  • 11. Bhogal P, Ganslandt O, Bäzner H, Henkes H, Pérez MA. The Fate of Side Branches Covered by Flow Diverters-Results from 140 Patients. World Neurosurgery 2017; 103: 789-798. doi: 10.1016/j.wneu.2017.04.092
  • 12. Iosif C, Berg P, Ponsonnard S, Carles P, Saleme S et al. Role of terminal and anastomotic circulation in the patency of arteries jailed by flow-diverting stents: animal flow model evaluation and preliminary results. Journal Neurosurgery 2016; 125 (4): 898-908. doi: 10.3171/2015.8.JNS151296
  • 13. Iosif C, Berg P, Ponsonnard S, Carles P, Saleme S et al. Role of terminal and anastomotic circulation in the patency of arteries jailed by flow-diverting stents: from hemodynamic changes to ostia surface modifications. Journal Neurosurgery 2017; 126 (5): 1702-1713. doi: 10.3171/2016.2.JNS152120
  • 14. Iosif C, Saleme S, Ponsonnard S, Carles P, Silveira EP et al. Intravascular optical coherence tomography for the evaluation of arterial bifurcations covered by flow diverters. Journal of NeuroInterventional Surgery 2016; 8 (12): 1283-1287. doi: 10.1136/neurintsurg-2015-012084.
  • 15. Darsaut TE, Bing F, Makoyeva A, Gevry G, Salazkin I et al. Flow diversion of giant curved sidewall and bifurcation experimental aneurysms with very-low-porosity devices. World Neurosurgery 2014; 82 (6): 1120-1126. doi: 10.1016/j. wneu.2013.09.036
  • 16. Darsaut TE, Bing F, Salazkin I, Gevry G, Raymond J. Flow diverters failing to occlude experimental bifurcation or curved sidewall aneurysms: an in vivo study in canines. Journal Neurosurgery 2012; 117 (1): 37-44. doi: 10.3171/2012.4.JNS111916
  • 17. Yavuz K, Geyik S, Saatci I, Cekirge HS. Endovascular treatment of middle cerebral artery aneurysms with flow modification with the use of the pipeline embolization device. American Journal of Neuroradiology 2014; 35 (3): 529-535. doi: 10.3174/ ajnr.A3692
  • 18. Bhatia KD, Kortman H, Orru E, Klostranec JM, Pereira VM et al. Periprocedural complications of second-generation flow diverter treatment using Pipeline Flex for unruptured intracranial aneurysms: a systematic review and meta-analysis. Journal of NeuroInterventional Surgery 2019; 11 (8): 817-824. doi: 10.1136/neurintsurg-2019-014937
  • 19. Saleme S, Iosif C, Ponomarjova S, Mendes G, Camilleri Y et al. Flow-diverting stents for intracranial bifurcation aneurysm treatment. Neurosurgery 2014; 75 (6): 623-631; quiz 631. doi: 10.1227/NEU.0000000000000522
  • 20. van Rooij WJ, Sluzewski M. Perforator infarction after placement of a pipeline flow-diverting stent for an unruptured A1 aneurysm. American Journal of Neuroradiology 2010; 31 (4): E43-4. doi: 10.3174/ajnr.A2034
  • 21. Wang CB, Shi WW, Zhang GX, Lu HC, Ma J. Flow diverter treatment of posterior circulation aneurysms. A meta-analysis. Neuroradiology 2016; 58 (4): 391-400. doi: 10.1007/s00234- 016-1649-2
  • 22. Rouchaud A, Leclerc O, Benayoun Y, Saleme S, Camilleri Y et al. Visual outcomes with flow-diverter stents covering the ophthalmic artery for treatment of internal carotid artery aneurysms. American Journal of Neuroradiology 2015; 36 (2): 330-336. doi: 10.3174/ajnr.A4129
  • 23. Vedantam A, Rao VY, Shaltoni HM, Mawad ME. Incidence and clinical implications of carotid branch occlusion following treatment of internal carotid artery aneurysms with the pipeline embolization device. Neurosurgery 2015; 76 (2): 173- 178; discussion 178. doi: 10.1227/NEU.0000000000000595
  • 24. Burrows AM, Brinjikji W, Puffer RC, Cloft H, Kallmes DF et al. Flow Diversion for Ophthalmic Artery Aneurysms. American Journal of Neuroradiology 2016; 37 (10): 1866-1869. doi: 10.3174/ajnr.A4835
  • 25. Puffer RC, Kallmes DF, Cloft HJ, Lanzino G. Patency of the ophthalmic artery after flow diversion treatment of paraclinoid aneurysms. Journal Neurosurgery 2012; 116 (4): 892-896. doi: 10.3171/2011.11.JNS111612
  • 26. Brinjikji W, Lanzino G, Cloft HJ, Kallmes DF. Patency of the posterior communicating artery after flow diversion treatment of internal carotid artery aneurysms. Clinical Neurology and Neurosurgery 2014; 120: 84-88. doi: 10.1016/j. clineuro.2014.02.018
  • 27. Neki H, Caroff J, Jittapiromsak P, Benachour N, Mihalea C et al. Patency of the anterior choroidal artery covered with a flow- diverter stent. Journal Neurosurgery 2015; 123 (6): 1540-1545. doi: 10.3171/2014.11.JNS141603
  • 28. Raz E, Shapiro M, Becske T, Zumofen DW, Tanweer O et al. Anterior choroidal artery patency and clinical follow-up after coverage with the pipeline embolization device. American Journal of Neuroradiology 2015; 36 (5): 937-942. doi: 10.3174/ ajnr.A4217
  • 29. Rangel-Castilla L, Munich SA, Jaleel N, Cress MC, Krishna C et al. Patency of anterior circulation branch vessels after Pipeline embolization: longer-term results from 82 aneurysm cases. Journal Neurosurgery 2017; 126(4): 1064-1069. doi: 10.3171/2016.4.JNS16147
  • 30. Cagnazzo F, Ahmed R, Lefevre PH, Derraz I, Dargazanli C et al. Flow modification on the internal carotid artery bifurcation region and A1 segment after M1-internal carotid artery flow diverter deployment. Journal of NeuroInterventional Surgery 2020;12(12):1226-1230.doi:10.1136/neurintsurg-2020-016051
  • 31. Xiang J, Damiano RJ, Lin N, Snyder KV, Siddiqui AH et al. High- fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms. Journal Neurosurgery 2015; 123 (4): 832-840. doi: 10.3171/2014.11.JNS14497
APA ONAN H, Pehlivan U, S, Köse S, Akgul E (2022). Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. , 965 - 974. 10.55730/1300-0144.5397
Chicago ONAN HASAN BİLEN,Pehlivan Umur Anil, Sinan,Köse Sevgül,Akgul Erol Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. (2022): 965 - 974. 10.55730/1300-0144.5397
MLA ONAN HASAN BİLEN,Pehlivan Umur Anil, Sinan,Köse Sevgül,Akgul Erol Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. , 2022, ss.965 - 974. 10.55730/1300-0144.5397
AMA ONAN H,Pehlivan U, S,Köse S,Akgul E Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. . 2022; 965 - 974. 10.55730/1300-0144.5397
Vancouver ONAN H,Pehlivan U, S,Köse S,Akgul E Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. . 2022; 965 - 974. 10.55730/1300-0144.5397
IEEE ONAN H,Pehlivan U, S,Köse S,Akgul E "Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents." , ss.965 - 974, 2022. 10.55730/1300-0144.5397
ISNAD ONAN, HASAN BİLEN vd. "Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents". (2022), 965-974. https://doi.org/10.55730/1300-0144.5397
APA ONAN H, Pehlivan U, S, Köse S, Akgul E (2022). Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. Turkish Journal of Medical Sciences, 52(4), 965 - 974. 10.55730/1300-0144.5397
Chicago ONAN HASAN BİLEN,Pehlivan Umur Anil, Sinan,Köse Sevgül,Akgul Erol Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. Turkish Journal of Medical Sciences 52, no.4 (2022): 965 - 974. 10.55730/1300-0144.5397
MLA ONAN HASAN BİLEN,Pehlivan Umur Anil, Sinan,Köse Sevgül,Akgul Erol Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. Turkish Journal of Medical Sciences, vol.52, no.4, 2022, ss.965 - 974. 10.55730/1300-0144.5397
AMA ONAN H,Pehlivan U, S,Köse S,Akgul E Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. Turkish Journal of Medical Sciences. 2022; 52(4): 965 - 974. 10.55730/1300-0144.5397
Vancouver ONAN H,Pehlivan U, S,Köse S,Akgul E Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents. Turkish Journal of Medical Sciences. 2022; 52(4): 965 - 974. 10.55730/1300-0144.5397
IEEE ONAN H,Pehlivan U, S,Köse S,Akgul E "Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents." Turkish Journal of Medical Sciences, 52, ss.965 - 974, 2022. 10.55730/1300-0144.5397
ISNAD ONAN, HASAN BİLEN vd. "Structural changes in the side branches and the circle of Willis following the use of flow- diverting stents". Turkish Journal of Medical Sciences 52/4 (2022), 965-974. https://doi.org/10.55730/1300-0144.5397