Yıl: 2022 Cilt: 25 Sayı: 4 Sayfa Aralığı: 318 - 322 Metin Dili: İngilizce DOI: 10.7126/cumudj.1204170 İndeks Tarihi: 18-01-2023

Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals

Öz:
Objectives: The aim of this study was to compare the simulated canal shaping efficiencies of five different NiTi rotary file systems. Materials and Methods: In the study, 100 transparent resin blocks with J-shaped canals were randomly divided into five groups (n=20). Simulated canals were shaped with VDW.Rotate (VR), TruNatomy (TRN), HyFlex CM (HF), EdgeFile X7 (EF), or ProTaper Next (PTN) files. Ten measuring points were detected on the pre- and post-preparation images taken from the blocks and superimposed. After preparation, the total canal width and the amount of transportation were calculated for the determined measuring levels. Zipping and ledge formation, instrument fracture and deformation, and change in working length were evaluated. The data were statistically analyzed with the Kolmogorov-Smirnov test, one-way ANOVA, Tukey test, Chi-Square test, and a Monte Carlo version of the Fisher Exact tests. The error level was taken as 0.05. Results: There were significant differences between the groups at all measuring levels in terms of total canal width after instrumentation (p = 0.001). Significant differences in the amount of transportation were found between the groups (p = 0.001) except at levels 4 (p = 0.169) and 10 (p = 0.054). Zip and instrument fractures did not occur in any group. 3 EF size 25/.04 files were deformed (p = 0.021). There was no significant difference between the groups in terms of ledge formation and working length change (p > 0.05). Conclusions: According to findings obtained in the study, transportation occurred at all 10 measuring levels with all file systems used. HF and EF systems were found to be more reliable in terms of transportation in the middle and coronal regions. Wider canal preparation was obtained with the PTN system in the middle and coronal regions.
Anahtar Kelime: Root canal transportation NiTi shaping efficiency simulated canal.

Beş Farklı Nikel-Titanyum Döner Eğe Sisteminin Yapay Kanallarda Şekillendirme Etkinliklerinin Karşılaştırmalı Olarak Değerlendirilmesi

Öz:
Amaç: Bu çalışmanın amacı, beş farklı NiTi döner eğe sisteminin yapay kanalları şekillendirme etkinliklerinin karşılaştırılmasıdır. Gereç ve Yöntem: Çalışmada 100 adet J şekilli kanala sahip şeffaf rezin blok, rastgele beş gruba ayrıldı (n=20). Yapay kanallar VDW.Rotate (VR), TruNatomy (TRN), HyFlex CM (HF), EdgeFile X7 (EF) veya ProTaper Next (PTN) eğeleriyle şekillendirildi. Bloklardan alınan ve çakıştırılan preparasyon öncesi ve sonrası görüntülerinin üzerinde 10 ölçüm seviyesi tespit edildi. Preparasyon sonrası toplam kanal genişliği ve transportasyon miktarı belirlenen ölçüm seviyeleri için hesaplandı. Zip, basamak oluşumu, alet kırığı, deformasyon ve çalışma boyunda meydana gelen değişim değerlendirildi. Veriler Kolmogorov-Smirnov testi, tek yönlü varyans analizi, Tukey testi, Khi-Kare testi ve Fisher Exact testlerden Monte Carlo modeliyle istatistiksel olarak analiz edilerek yanılma düzeyi 0,05 olarak alındı. Bulgular: Tüm ölçüm seviyelerinde preparasyon sonrası toplam kanal genişliği yönünden gruplar arasında anlamlı farklar bulundu (p = 0,001). Seviye 4 (p = 0,169) ve 10 (p = 0,054) dışındaki ölçüm seviyelerinde gruplar arasında transportasyon miktarı açısından önemli farklılıklar bulundu (p = 0,001). Hiçbir grupta zip ve alet kırığı oluşmadı. 3 tane EF 25/.04 boyutlu eğe deforme oldu (p = 0,021). Basamak oluşumu ve çalışma boyu değişimi yönünden ise gruplar arasında anlamlı fark gözlenmedi (p > 0,05). Sonuçlar: Çalışmada elde edilen bulgulara göre kullanılan tüm eğe sistemleriyle 10 ölçüm seviyesinde de transportasyon meydana geldi. HF ve EF sistem orta ve koronal bölgede transportasyon yönünden daha güvenilir bulundu. PTN sistemiyle orta ve koronal bölgede daha geniş kanal preparasyonu elde edildi.
Anahtar Kelime: Kök kanal transportasyonu NiTi şekillendirme etkinliği yapay kanal.

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Bibliyografik
  • 1. Hammad M, Qualtrough A, Silikas N. Evaluation of root canal obturation: a three-dimensional in vitro study. J Endod 2009;35:541-544.
  • 2. Yang L, Chen X, Tian C, Han T, Wang Y. Use of cone-beam computed tomography to evaluate root canal morphology and locate root canal orifices of maxillary second premolars in a Chinese subpopulation. J Endod 2014;40:630-634.
  • 3. Al Omari T, El-Farraj H, Arican B, Atav Ates A. Apical debris extrusion of full-sequenced rotary systems in narrow ribbon- shaped canals. Aust Endod J 2022;48:245-250.
  • 4. Ertugrul IF, Orhan EO. Cyclic fatigue and energy-dispersive X- ray spectroscopy examination of the novel ROTATE instrument. Microsc Res Tech 2019;82:2042-2048.
  • 5. Mustafa R, Al Omari T, Al-Nasrawi S, Al Fodeh R, Dkmak A, Haider J. Evaluating In Vitro Performance of Novel Nickel- Titanium Rotary System (TruNatomy) Based on Debris Extrusion and Preparation Time from Severely Curved Canals. J Endod 2021;47:976-981.
  • 6. Burklein S, Borjes L, Schafer E. Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel- titanium instruments. Int Endod J 2014;47:470-476.
  • 7. Gambarini G, Galli M, Seracchiani M, Di Nardo D, Versiani MA, Piasecki L, et al. In Vivo Evaluation of Operative Torque Generated by Two Nickel-Titanium Rotary Instruments during Root Canal Preparation. Eur J Dent 2019;13:556-562.
  • 8. Ashok L, Krishnan V, Nair RS, Angelo MC. An Overview of Thermomechanically Heat-treated Nickel–Titanium Alloy Used in Endodontics. Cons Dent Endod J 2019;4:34-38.
  • 9. Arias A, Singh R, Peters OA. Torque and force induced by ProTaper universal and ProTaper next during shaping of large and small root canals in extracted teeth. J Endod 2014;40:973- 976.
  • 10. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 1971;32:271-275.
  • 11. Altunbas D, Kutuk B, Kustarci A. Shaping ability of reciprocating single-file and full-sequence rotary instrumentation systems in simulated curved canals. Eur J Dent 2015;9:346-351.
  • 12. Keskin C, Sariyilmaz E, Demiral M. Shaping ability of Reciproc Blue reciprocating instruments with or without glide path in simulated S-shaped root canals. J Dent Res Dent Clin Dent Prospects 2018;12:63-67.
  • 13. Piț AB, Borcean IA, Vărgatu IA, Mai A, Shyblak M, Mokdad S, et al. Evaluation of the time and efficiency of trunatomy, vdw. rotate, protaper gold and reciproc blue in shaping root canals- an in vitro study. Rom J Oral Rehabil 2020;12.
  • 14. Lopez FU, Fachin EV, Camargo Fontanella VR, Barletta FB, So MV, Grecca FS. Apical transportation: a comparative evaluation of three root canal instrumentation techniques with three different apical diameters. J Endod 2008;34:1545- 1548.
  • 15. Schafer E, Dzepina A, Danesh G. Bending properties of rotary nickel-titanium instruments. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003;96:757-763.
  • 16. Zhao D, Shen Y, Peng B, Haapasalo M. Micro-computed tomography evaluation of the preparation of mesiobuccal root canals in maxillary first molars with Hyflex CM, Twisted Files, and K3 instruments. J Endod 2013;39:385-388.
  • 17. Ozer SY. Comparison of root canal transportation induced by three rotary systems with noncutting tips using computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:244-250.
  • 18. Saber SE, Nagy MM, Schafer E. Comparative evaluation of the shaping ability of ProTaper Next, iRaCe and Hyflex CM rotary NiTi files in severely curved root canals. Int Endod J 2015;48:131-136.
  • 19. Huang Z, Quan J, Liu J, Zhang W, Zhang X, Hu X. A microcomputed tomography evaluation of the shaping ability of three thermally-treated nickel-titanium rotary file systems in curved canals. J Int Med Res 2019;47:325-334.
  • 20. Kim H, Jeon SJ, Seo MS. Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals. BMC Oral Health 2021;21:533.
  • 21. Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root fillings. J Endod 2000;26:210-216.
  • 22. Bürklein S, Schäfer E. Critical evaluation of root canal transportation by instrumentation. Endod Top 2013;29:110- 124.
  • 23. Alodeh MH, Dummer PM. A comparison of the ability of K-files and Hedstrom files to shape simulated root canals in resin blocks. Int Endod J 1989;22:226-235.
  • 24. Radwański M, Łęski M, Pawlicka H. The influence of the manufacturing process of rotary files on the shaping of L- shaped canals. Dent Med Probl 2018;55:389-394.
APA bilgin ö, altunbaş d (2022). Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. , 318 - 322. 10.7126/cumudj.1204170
Chicago bilgin ömer,altunbaş demet Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. (2022): 318 - 322. 10.7126/cumudj.1204170
MLA bilgin ömer,altunbaş demet Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. , 2022, ss.318 - 322. 10.7126/cumudj.1204170
AMA bilgin ö,altunbaş d Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. . 2022; 318 - 322. 10.7126/cumudj.1204170
Vancouver bilgin ö,altunbaş d Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. . 2022; 318 - 322. 10.7126/cumudj.1204170
IEEE bilgin ö,altunbaş d "Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals." , ss.318 - 322, 2022. 10.7126/cumudj.1204170
ISNAD bilgin, ömer - altunbaş, demet. "Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals". (2022), 318-322. https://doi.org/10.7126/cumudj.1204170
APA bilgin ö, altunbaş d (2022). Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. Cumhuriyet Dental Journal , 25(4), 318 - 322. 10.7126/cumudj.1204170
Chicago bilgin ömer,altunbaş demet Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. Cumhuriyet Dental Journal 25, no.4 (2022): 318 - 322. 10.7126/cumudj.1204170
MLA bilgin ömer,altunbaş demet Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. Cumhuriyet Dental Journal , vol.25, no.4, 2022, ss.318 - 322. 10.7126/cumudj.1204170
AMA bilgin ö,altunbaş d Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. Cumhuriyet Dental Journal . 2022; 25(4): 318 - 322. 10.7126/cumudj.1204170
Vancouver bilgin ö,altunbaş d Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals. Cumhuriyet Dental Journal . 2022; 25(4): 318 - 322. 10.7126/cumudj.1204170
IEEE bilgin ö,altunbaş d "Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals." Cumhuriyet Dental Journal , 25, ss.318 - 322, 2022. 10.7126/cumudj.1204170
ISNAD bilgin, ömer - altunbaş, demet. "Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals". Cumhuriyet Dental Journal 25/4 (2022), 318-322. https://doi.org/10.7126/cumudj.1204170