Yıl: 2023 Cilt: 26 Sayı: 1 Sayfa Aralığı: 42 - 46 Metin Dili: İngilizce DOI: 10.7126/cumudj.1213288 İndeks Tarihi: 11-09-2023

Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions

Öz:
Objective: The purpose of this in vitro study was to evaluate the effect of plastic impression-transfer copings on the dimensional accuracy of close tray implant impressions. Material and Methods: A master model consisting of acrylic main material was created. Five parallel holes were drilled for the analogs. Special measuring spoons were prepared for the models created with self-hardening polymethyl methacrylate resin. Our research consisted of 2 groups. The first group consisted of five parts and the impression was taken using the Implant Plastic impression-transfer part coping method. The second group, on the other hand, consists of five parts, and this time measurements were taken without using the Plastic impression-transfer coping method. Vinylpolysiloxane impression material was used for both groups. At the end of the impression process, plaster models were made with type IV calculus. The plaster models were scanned with laboratory-type scanner and recorded in the measurement program. To create a standard operation between the groups, measurements were made of each analog from a certain reference point. Measurement results were recorded in millimeters and pairwise comparisons were made using Welch's t-test analysis. Results: How the plastic impression caps affect the measures was concluded by applying the t-test to each point. The deterioration in the measurements taken with the cap was lower for all distances compared to the measurements taken without the cap, but the difference was not significant (p>0.05). Conclusions: While the distortions seen in the right and left measured intervals were found as the expansion type, the distortions in the posterior and anterior intervals were determined as the compression type. Although there are dimensional changes in the measurements taken without the use of a cap, the findings were not found to be clinically significant.
Anahtar Kelime: Dental implant implant impression plastic impression transfer coping dimensional accuracy fastened impression coping

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Bibliyografik
  • 1. Nuzzolese E, Lepore MMI, Cukovic-Bagic FM, Vella G D. Forensic sciences and forensic odontology. International Dental Journal 2008;58(6): 342–348.
  • 2. Tabesh M, Alikhasi M, Siadat H. A Comparison of implant impression precision: Different materials and techniques. Journal of Clinical and Experimental Dentistry 2018;10(2): 151–157.
  • 3. Aguilar M L, Elias A, Vizcarrondo C E T, Psoter W J. Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. Journal of Prosthetic Dentistry 2010;103(4):202–209.
  • 4. Chang WG, Vahidi F, Bae KH, Lim BS. Accuracy of three implant impression techniques with different impression materials and stones. The International Journal of Prosthodontics 2012;25(1): 44–47.
  • 5. Alsharbaty MHM, Alikhasi M, Zarrati S, Shamshiri AR. A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques. Journal of Prosthodontics 2019;28(4): 902–908.
  • 6. Moura RV, Kojima AN, Saraceni CHC, Bassolli L, Balducci I, Özcan M, Mesquita AMM. Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations. Journal of Prosthodontics 2019;28(2): 530–535.
  • 7. Fernandez M A, Paez de Mendoza CY, Platt JA, Levon JA, Hovijitra ST, Nimmo A. A comparative study of the accuracy between plastic and metal impression-transfer copings for implant restorations. Journal of Prosthodontics 2013;22(5): 367–376.
  • 8. Hariharan R, Shankar M D S C, Rajan MDSM. Evaluation of Accuracy of Multiple Dental Implant. The International Journal of Oral & Maxillofacial Implants 2010;25(1):38-44.
  • 9. Tan JZH, Tan MY, See Toh YL, Wong KY, Tan KBC. Three-dimensional positional accuracy of intraoral and laboratory implant scan bodies. J Prosthet Dent. 2022 Oct;128(4):735-744.
  • 10. Alshawaf B, Weber HP, Finkelman M, El Rafie K, Kudara Y, Papaspyridakos P. Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study. Clin Oral Implants Res. 2018 Aug;29(8):835-842.
  • 11. Alikhasi M, Siadat H, Nasirpour A, Hasanzade M. Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type. Int J Dent. 2018 Jun 4;2018:3761750.
  • 12. Punj A, Bompolaki D, Garaicoa J. Dental Impression Materials and Techniques. Dent Clin North Am. 2017 Oct;61(4):779-796.
  • 13. Bandiaky ON, Le Bars P, Gaudin A, Hardouin JB, Cheraud-Carpentier M, Mbodj EB, Soueidan A. Comparative assessment of complete-coverage, fixed tooth-supported prostheses fabricated from digital scans or conventional impressions: A systematic review and meta-analysis. J Prosthet Dent. 2022 Jan;127(1):71-79.
  • 14. Nakhaei M, Madani AS, Moraditalab A, Haghi HR. Three-dimensional accuracy of different impression techniques for dental implants. Dent Res J (Isfahan) 2015; Sep-Oct;12(5):431-437.
  • 15. Arieli A, Adawi M, Masri M, Weinberg E, Beitlitum I, Pilo R, Levartovsky S. The Accuracy of Open-Tray vs. Snap on Impression Techniques in A 6-Implant Model: An In Vitro 3D Study. Materials (Basel). 2022 Mar 12;15(6):2103.
APA Coşkun A, Koyu T, Yeşilyurt G, ULGEY M, Gorler O (2023). Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. , 42 - 46. 10.7126/cumudj.1213288
Chicago Coşkun Akın,Koyu Tuğçe,Yeşilyurt Gizem,ULGEY MELİH,Gorler Oguzhan Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. (2023): 42 - 46. 10.7126/cumudj.1213288
MLA Coşkun Akın,Koyu Tuğçe,Yeşilyurt Gizem,ULGEY MELİH,Gorler Oguzhan Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. , 2023, ss.42 - 46. 10.7126/cumudj.1213288
AMA Coşkun A,Koyu T,Yeşilyurt G,ULGEY M,Gorler O Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. . 2023; 42 - 46. 10.7126/cumudj.1213288
Vancouver Coşkun A,Koyu T,Yeşilyurt G,ULGEY M,Gorler O Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. . 2023; 42 - 46. 10.7126/cumudj.1213288
IEEE Coşkun A,Koyu T,Yeşilyurt G,ULGEY M,Gorler O "Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions." , ss.42 - 46, 2023. 10.7126/cumudj.1213288
ISNAD Coşkun, Akın vd. "Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions". (2023), 42-46. https://doi.org/10.7126/cumudj.1213288
APA Coşkun A, Koyu T, Yeşilyurt G, ULGEY M, Gorler O (2023). Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. Cumhuriyet Dental Journal , 26(1), 42 - 46. 10.7126/cumudj.1213288
Chicago Coşkun Akın,Koyu Tuğçe,Yeşilyurt Gizem,ULGEY MELİH,Gorler Oguzhan Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. Cumhuriyet Dental Journal 26, no.1 (2023): 42 - 46. 10.7126/cumudj.1213288
MLA Coşkun Akın,Koyu Tuğçe,Yeşilyurt Gizem,ULGEY MELİH,Gorler Oguzhan Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. Cumhuriyet Dental Journal , vol.26, no.1, 2023, ss.42 - 46. 10.7126/cumudj.1213288
AMA Coşkun A,Koyu T,Yeşilyurt G,ULGEY M,Gorler O Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. Cumhuriyet Dental Journal . 2023; 26(1): 42 - 46. 10.7126/cumudj.1213288
Vancouver Coşkun A,Koyu T,Yeşilyurt G,ULGEY M,Gorler O Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions. Cumhuriyet Dental Journal . 2023; 26(1): 42 - 46. 10.7126/cumudj.1213288
IEEE Coşkun A,Koyu T,Yeşilyurt G,ULGEY M,Gorler O "Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions." Cumhuriyet Dental Journal , 26, ss.42 - 46, 2023. 10.7126/cumudj.1213288
ISNAD Coşkun, Akın vd. "Effect of Plastic Impression-Transfer Copings on the Dimensional Accuracy of Implant Impressions". Cumhuriyet Dental Journal 26/1 (2023), 42-46. https://doi.org/10.7126/cumudj.1213288