Yıl: 2022 Cilt: 2 Sayı: 3 Sayfa Aralığı: 9 - 14 Metin Dili: İngilizce DOI: 10.14744/eer.2022.29200 İndeks Tarihi: 21-05-2023

Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes

Öz:
Purpose: The objective of the study was to evaluate the error in predicted residual astigmatism (PRA) using measurements of corneal astigmatism obtained with IOLMaster-700 and Pentacam for toric intraocular lens (IOL) calculation in keratoconic eyes. Methods: For toric IOL calculations, we used keratometric astigmatism obtained by IOLMaster-700 and total corneal re- fractive power (TCRP) values determined by Pentacam Scheimpflug system. Using an online toric IOL calculator, PRA for keratometric astigmatism and TCRP with a toric IOL model suggested for keratometric astigmatism values was recorded. We also calculated the error in PRA as the difference between PRA with keratometric astigmatism and TCRP. For all calculations, vector analysis was used. Results: In our sample of 70 keratoconic eyes of 70 patients, the mean difference in PRA using TCRP instead of keratometric astigmatism measurements was −1.21±0.93 with a centroid of 0.85 at 25. The error in PRA was ≤1.0D in 36 eyes, between 1.0D and 3.0D in 26 eyes, and between 3.0D and 4.0D in eight eyes. Whereas 80% of eyes with with-the-rule astigmatism showed decreased cylindrical IOL power, 88.9% of eyes with against-the-rule astigmatism showed increased IOL power with TCRP instead of keratometric astigmatism. Conclusion: Using TCRP measurements instead of keratometric astigmatism in toric IOL calculations caused a considerable deviation in eyes with keratoconus, most probably due to the posterior corneal astigmatism.
Anahtar Kelime: IOLMaster 700 keratoconus Pentacam posterior corneal astigmatism toric intraocular lenses.

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • Navas A, Suarez R. One-year follow-up of toric intraocular lens implantation in forme fruste keratoconus. J Cataract Refract Surg 2009;35:2024–7.
  • Visser N, Gast ST, Bauer NJ, Nuijts RM. Cataract surgery with to- ric intraocular lens implantation in keratoconus: A case report. Cornea 2011;30:720–3.
  • Jaimes M, Xacur-García F, Alvarez-Melloni D, Graue-Hernán- dez EO, Ramirez-Luguín T, Navas A. Refractive lens exchange with toric intraocular lenses in keratoconus. J Refract Surg 2011;27:658–4.
  • Nanavaty MA, Lake DB, Daya SM. Outcomes of pseudophakic toric intraocular lens implantation in keratoconic eyes with cataract. J Refract Surg 2012;28:884–9.
  • Alió JL, Peña-García P, Guliyeva AF, Soria FA, Zein G, Abu-Mus- tafa SK. MICS with toric intraocular lenses in keratoconus: Out- comes and predictability analysis of postoperative refraction. Br J Ophthalmol 2014;98:365–70.
  • Hashemi H, Heidarian S, Seyedian MA, Yekta A, Khabazk- hoob M. Evaluation of the results of using toric IOL in the cataract surgery of keratoconus patients. Eye Contact Lens 2015;41:354–8.
  • Savini G, Næser K. An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest Ophthalmol Vis Sci 2015;56:827–35.
  • Savini G, Næser K, Schiano-Lomoriello D, Mularoni A. Influence of posterior corneal astigmatism on total corneal astig- matism in eyes with keratokonus. Cornea 2016;35:1427–33.
  • Rabinowitz YS. Keratoconus. Surv Ophthalmol 1998;42:297– 319.
  • Krumeich JH, Kezirian GM. Circular keratotomy to reduce astigmatism and improve vision in stage I and II keratoconus. J Refract Surg 2009;25:357–65.
  • Klyce SD. Chasing the suspect: Keratoconus. Br J Ophthalmol 2009;93:845–7.
  • Grulkowski I, Liu JJ, Zhang JY, Potsaid B, Jayaraman V, Cable AE, et al. Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and compar- ison with clinical biometers. Ophthalmology 2013;120:2184 90.
  • Holladay JT, Moran JR, Kezirian GM. Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism. J Cataract Refract Surg 2001;27:61–79.
  • Gupta PC, Caty JT. Astigmatism evaluation prior to cataract surgery. Curr Opin Ophthalmol 2018;29:9 13.
  • Zhang L, Sy ME, Mai H, Yu F, Hamilton DR. Effect of posterior corneal astigmatism on refractive outcomes after toric intraocular lens implantation. J Cataract Refract Surg 2015;41:84 9.
  • Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L. Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg 2012;38:2080 7.
  • Ho JD, Liou SW, Tsai RJ, Tsai CY. Effects of aging on anterior and posterior corneal astigmatism. Cornea 2010;29:632–7.
  • Kamiya K, Shimizu K, Igarashi A, Miyake T. Assessment of anterior, posterior, and total central astigmatism in eyes with keratoconus. Am J Ophthalmol 2015;160:851 7.e.1.
  • Savini G, Abbate R, Hoffer KJ, Mularoni A, Imburgia A, Avoni L, et al. Intraocular lens power calculation in eyes with keratoconus. J Cataract Refract Surg 2019;45:576 81.
  • Bozorg S, Pineda R. Cataract and keratoconus: Minimizing complications in intraocular lens calculations. Semin Ophthalmol 2014;29:376 9.
  • Kawamorita T, Nakayama N, Uozato H. Repeatability and reproducibility of corneal curvature measurements using the pentacam and keratron topography systems. J Refract Surg 2009;25:539–44.
  • Srivannaboon S, Chirapapaisan C, Chonpimai P, Loket S. Clinical comparison of a new swept-source optical coherence to- mography-based optical biometer and a time-domain optical coherence tomography-based optical biometer. J Cataract Refract Surg 2015;41:2224 32.
  • Özyol P, Özyol E. Agreement between swept-source optical biometry and scheimpflug-based topography measure- ments of anterior segment parameters. Am J Ophthalmol 2016;169:73–8.
  • Other Cited Material A. Alcon, Inc. AcrySof® Toric IOL Web Based Calculators. Available from: https://www.acrysoftoriccalculator.com.
APA Özyol E, Özyol P (2022). Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. , 9 - 14. 10.14744/eer.2022.29200
Chicago Özyol Erhan,Özyol Pelin Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. (2022): 9 - 14. 10.14744/eer.2022.29200
MLA Özyol Erhan,Özyol Pelin Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. , 2022, ss.9 - 14. 10.14744/eer.2022.29200
AMA Özyol E,Özyol P Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. . 2022; 9 - 14. 10.14744/eer.2022.29200
Vancouver Özyol E,Özyol P Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. . 2022; 9 - 14. 10.14744/eer.2022.29200
IEEE Özyol E,Özyol P "Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes." , ss.9 - 14, 2022. 10.14744/eer.2022.29200
ISNAD Özyol, Erhan - Özyol, Pelin. "Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes". (2022), 9-14. https://doi.org/10.14744/eer.2022.29200
APA Özyol E, Özyol P (2022). Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. European eye research, 2(3), 9 - 14. 10.14744/eer.2022.29200
Chicago Özyol Erhan,Özyol Pelin Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. European eye research 2, no.3 (2022): 9 - 14. 10.14744/eer.2022.29200
MLA Özyol Erhan,Özyol Pelin Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. European eye research, vol.2, no.3, 2022, ss.9 - 14. 10.14744/eer.2022.29200
AMA Özyol E,Özyol P Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. European eye research. 2022; 2(3): 9 - 14. 10.14744/eer.2022.29200
Vancouver Özyol E,Özyol P Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes. European eye research. 2022; 2(3): 9 - 14. 10.14744/eer.2022.29200
IEEE Özyol E,Özyol P "Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes." European eye research, 2, ss.9 - 14, 2022. 10.14744/eer.2022.29200
ISNAD Özyol, Erhan - Özyol, Pelin. "Impact of posterior corneal astigmatism on deviation in predicted residual astigmatism for toric IOL calculations in keratoconic eyes". European eye research 2/3 (2022), 9-14. https://doi.org/10.14744/eer.2022.29200