Yıl: 2022 Cilt: 2 Sayı: 3 Sayfa Aralığı: 47 - 50 Metin Dili: İngilizce DOI: 10.14744/eer.2022.43531 İndeks Tarihi: 21-05-2023

Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect

Öz:
The aim of this study was to assess the efficacy of sutureless amniotic membrane (AM) technique using a symblepharon ring-AM patch on the persistent epithelial defects and resistant to medical treatment. Two patients to whom an AM patch was applied to the ocular surface using a polymethyl methacrylate symblepharon ring due to corneal surface disorders are evaluated. The implantation of ring-AM was not complicated. Irritation and epithelial defect decreased in both cases. Eventually, vascularized leukoma developed. Ring-AM implantation is a non-invasive and easy procedure in the treatment of ocular surface disease. Ring-AM is an effective and safe biologic bandage in patients, who refuse surgical procedure or to whom surgery is contraindicated due to systemic diseases.
Anahtar Kelime: Amniotic membrane corneal epithelial defects symblepharon ring.

Belge Türü: Makale Makale Türü: Olgu Sunumu Erişim Türü: Erişime Açık
  • Espana EM, Prabhasawat P, Grueterich M, Solomon A, Tseng SC. Amniotic membrane transplantation for reconstruction after excision of large ocular surface neoplasias. Br J Ophthalmol 2002;86:640–5.
  • Liu BQ, Wang ZC, Liu LM, Liu JB, Li NY, Wang LN, et al. Suture- less fixation of amniotic membrane patch as a therapeutic contact lens by using a polymethyl methacrylate ring and fib- rin sealant in a rabbit model. Cornea 2008;27:74–9.
  • Ma KN, Thanos A, Chodosh J, Shah AS, Mantagos IS. A novel technique for amniotic membrane transplantation in patients with acute Stevens-Johnson syndrome. Ocul Surf 2016;14:31– 6.
  • Takaoka M, Nakamura T, Sugai H, Bentley AJ, Nakajima N, Fullwood NJ, et al. Sutureless amniotic membrane transplan- tation for ocular surface reconstruction with a chemically de- fined bioadhesive. Biomaterials 2008;29:2923–31.
  • Kara N. Sutureless amniotic membrane transplantation with a modified ocular surface ring. Can J Ophthalmol 2018;53:e46– 8.
  • Ghaddar H, Teja S, Conlon R, Teichman J, Yeung S, Baig K. Ocular surface reconstruction with human amniotic mem- brane-symblepharon ring complex. Can J Ophthalmol 2016;51:e129–31.
  • Kotomin I, Valtink M, Hofmann K, Frenzel A, Morawietz H, Werner C, et al. Sutureless fixation of amniotic mem- brane for therapy of ocular surface disorders. PLoS One 2015;10:e0125035.
  • Kheirkhah A, Casas V, Raju VK, Tseng SC. Sutureless amniotic membrane transplantation for partial limbal stem cell defi- ciency. Am J Ophthalmol 2008;145:787–94.
  • Liang X, Liu Z, Lin Y, Naiyang Li, Huang M, Wang Z. A mod- ified symblepharon ring for sutureless amniotic membrane patch to treat acute ocular surface burns. J Burn Care Res 2012;33:e32–8.
  • Dogan C, Arslan OS, Ozdamar A, Mergen B, Sarici AM, Iskeleli G. Efficacy of fixation of the amniotic membrane on a symble- pharon ring with continous suturing in acute ocular chemical burn patients. Int Ophthalmol 2019;39:2103–9.
APA Ozcan A, ULAS B (2022). Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. , 47 - 50. 10.14744/eer.2022.43531
Chicago Ozcan Altan Atakan,ULAS Burak Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. (2022): 47 - 50. 10.14744/eer.2022.43531
MLA Ozcan Altan Atakan,ULAS Burak Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. , 2022, ss.47 - 50. 10.14744/eer.2022.43531
AMA Ozcan A,ULAS B Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. . 2022; 47 - 50. 10.14744/eer.2022.43531
Vancouver Ozcan A,ULAS B Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. . 2022; 47 - 50. 10.14744/eer.2022.43531
IEEE Ozcan A,ULAS B "Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect." , ss.47 - 50, 2022. 10.14744/eer.2022.43531
ISNAD Ozcan, Altan Atakan - ULAS, Burak. "Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect". (2022), 47-50. https://doi.org/10.14744/eer.2022.43531
APA Ozcan A, ULAS B (2022). Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. European eye research, 2(3), 47 - 50. 10.14744/eer.2022.43531
Chicago Ozcan Altan Atakan,ULAS Burak Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. European eye research 2, no.3 (2022): 47 - 50. 10.14744/eer.2022.43531
MLA Ozcan Altan Atakan,ULAS Burak Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. European eye research, vol.2, no.3, 2022, ss.47 - 50. 10.14744/eer.2022.43531
AMA Ozcan A,ULAS B Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. European eye research. 2022; 2(3): 47 - 50. 10.14744/eer.2022.43531
Vancouver Ozcan A,ULAS B Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect. European eye research. 2022; 2(3): 47 - 50. 10.14744/eer.2022.43531
IEEE Ozcan A,ULAS B "Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect." European eye research, 2, ss.47 - 50, 2022. 10.14744/eer.2022.43531
ISNAD Ozcan, Altan Atakan - ULAS, Burak. "Symblepharon ring-amniotic membrane application in persistent corneal epithelial defect". European eye research 2/3 (2022), 47-50. https://doi.org/10.14744/eer.2022.43531