Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning

Öz:
Introduction: The algorithms used in the GammaPlan treatment planning system are “Tissue Maximum Ratio (TMR) classical,”“TMR 10,” and “convolution” algorithms, respectively. In this study, the consistency of dosimetric measurements with the TMR 10 protocol used in SRC (stereotactic radiosurgery) planning in lesions located in homogeneous and inhomogeneous regions in different intracranial location scenarios was investigated. Methods: In this study, the accuracy of administration of multiple metastasis treatment on the Gamma Knife Perfexion device was investigated. Computed tomography was performed with 1 mm cross-section intervals of CIRS brand Atom randofantoma. Critical organs and three different brain metastases located in homogeneous and heterogeneous regions, which are not on the same plane with each other, were drawn on the phantom. Planned target volume (PTV) volumes were created without margining the drawn gross tumor volumes, and three separate plans were made for three different PTV volumes. All plans were calculated using the TMR 10 algorithm. Critical organ doses were kept below the brain-SRC criteria for all calculated plans. Gafchromic EBT-3 film was placed on the sections with the target volume drawn on the phantoms and irradiated (1600 cGy, 50% isodose area). Measurements were made three times. The measured film results and the doses calculated from the planning were compared with gamma index analysis for different tolerance values. Results: In our study, for three different lesions planned and irradiated with different gradient index values, a difference of 2.11–9.58% was observed between the values calculated with the TMR-10 protocol and the values obtained in the dosimet- ric measurement. A decrease in consistency was observed, especially in inhomogeneous region placements. Discussion and Conclusion: There may be inconsistency between the TMR-10 protocol and actual dosimetric measurements, especially around inhomogeneous intracranial structures. We hope that this inconsistency will decrease in the future with the developing dose calculation protocols.
Anahtar Kelime: Dosimetry gamma knife gammaplan radiosurgery TMR-10 algorithm.

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
0
0
0
  • Leksell L. Stereotactic radiosurgery. J Neurol Neurosurg Psychiatry 1983;46:797–803.
  • Duggar WN, He R, Bhandari R, Kanakamedala M, Morris B, ReyDios R, et al. Considering inhomogeneities in Gamma Knife treatment planning: Factors affecting the loss of prescription dose coverage†. J Radiosurg SBRT 2020;6:303–10.
  • Chung HT, Park JH, Chun KJ. Verification of dose profiles generated by the convolution algorithm of the gamma knife® radiosurgery planning system. Med Phys 2017;44:4880–89.
  • Pipek J, Novotny Jr J, Novotny J, Kozubikova P. Comparison of dose calculation algorithms for Leksell gamma knife perfex- ion using Monte Carlo voxel phantoms. Lekar a technika – ClinTechnol 2015;45:75–81.
  • Choi HJ, Chung HT, Sohn JW, Min CH. Independent dose validation system for Gamma Knife radiosurgery, using a DICOM-RT interface and Geant4. Phys Med 2018;51:117–24. Xu AY, Bhatnagar J, Bednarz G, Niranjan A, Flickinger J, Lunsford LD, et al. Dose differences between the three dose calculation algorithms in Leksell GammaPlan. J Appl Clin Med Phys 2014;15:4844.
APA TÖNGE M, YAZICI Ö, İPEK V, DEMIR H (2022). Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. , 88 - 94. 10.14744/hnhj.2022.04372
Chicago TÖNGE Mehmet,YAZICI Ömer,İPEK Veyselkarani,DEMIR Hilal ACAR Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. (2022): 88 - 94. 10.14744/hnhj.2022.04372
MLA TÖNGE Mehmet,YAZICI Ömer,İPEK Veyselkarani,DEMIR Hilal ACAR Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. , 2022, ss.88 - 94. 10.14744/hnhj.2022.04372
AMA TÖNGE M,YAZICI Ö,İPEK V,DEMIR H Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. . 2022; 88 - 94. 10.14744/hnhj.2022.04372
Vancouver TÖNGE M,YAZICI Ö,İPEK V,DEMIR H Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. . 2022; 88 - 94. 10.14744/hnhj.2022.04372
IEEE TÖNGE M,YAZICI Ö,İPEK V,DEMIR H "Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning." , ss.88 - 94, 2022. 10.14744/hnhj.2022.04372
ISNAD TÖNGE, Mehmet vd. "Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning". (2022), 88-94. https://doi.org/10.14744/hnhj.2022.04372
APA TÖNGE M, YAZICI Ö, İPEK V, DEMIR H (2022). Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. Haydarpaşa Numune Medical Journal, 62(4), 88 - 94. 10.14744/hnhj.2022.04372
Chicago TÖNGE Mehmet,YAZICI Ömer,İPEK Veyselkarani,DEMIR Hilal ACAR Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. Haydarpaşa Numune Medical Journal 62, no.4 (2022): 88 - 94. 10.14744/hnhj.2022.04372
MLA TÖNGE Mehmet,YAZICI Ömer,İPEK Veyselkarani,DEMIR Hilal ACAR Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. Haydarpaşa Numune Medical Journal, vol.62, no.4, 2022, ss.88 - 94. 10.14744/hnhj.2022.04372
AMA TÖNGE M,YAZICI Ö,İPEK V,DEMIR H Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. Haydarpaşa Numune Medical Journal. 2022; 62(4): 88 - 94. 10.14744/hnhj.2022.04372
Vancouver TÖNGE M,YAZICI Ö,İPEK V,DEMIR H Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning. Haydarpaşa Numune Medical Journal. 2022; 62(4): 88 - 94. 10.14744/hnhj.2022.04372
IEEE TÖNGE M,YAZICI Ö,İPEK V,DEMIR H "Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning." Haydarpaşa Numune Medical Journal, 62, ss.88 - 94, 2022. 10.14744/hnhj.2022.04372
ISNAD TÖNGE, Mehmet vd. "Dosimetric Phantom Consistency of TMR-10 Protocol in Homogeneous and Inhomogeneous Regions in Gamma Knife Radiosurgery Planning". Haydarpaşa Numune Medical Journal 62/4 (2022), 88-94. https://doi.org/10.14744/hnhj.2022.04372