Yıl: 2023 Cilt: 50 Sayı: 1 Sayfa Aralığı: 28 - 34 Metin Dili: İngilizce DOI: 10.52037/eads.2023.0007 İndeks Tarihi: 31-05-2023

Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems

Öz:
Purpose: This study aims to investigate the effect of 4 different scanning protocols offered by the VistaScan Mini Easy scanner on image quality at different exposure times. Materials and Methods: Four number size-2 photostimulable phosphor plates were exposed with 5 different exposure times while keeping the other parameters constant. The exposed plates were scanned without delay using 4 different scanning protocols. 10 lp/mm, 20 lp/mm, 25 lp/mm, and 40 lp/mm are offered by the VistaScan Mini Easy scanner. The mean gray value was calculated using the ImageJ program by identifying three non-overlapping regions of interest from the background and each step in the obtained images. The mean of all mean gray values determined for the background and steps on a plate was also considered the mean gray value of that plate. Results: When plate mean gray values at 0.20 s and 0.40 s were examined, a statistically signiőcant difference was observed between the scanning protocols (p<0.001, p=0.001 respectively). It was determined that the plate mean gray value at 40 lp/mm in 0.20 s was lower than that of other scanning protocols. The plate mean gray value at 20 lp/mm in 0.20 s was higher than that at 25 lp/mm. It was determined that the plate mean gray value at 10 lp/mm in 0.40 s was lower than that of the other groups. Conclusions: The effect of spatial resolution on diagnostics in digital imaging per se is a subject under investigation and still not agreed upon.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Farman AG, Farman TT. A comparison of 18 different x-ray detectors currently used in dentistry. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2005;99(4):485ś9. doi:10.1016/j.tripleo.2004.04.002.
  • 2. Vandenberghe B, Jacobs R, Bosmans H. Modern dental imaging: a review of the current technology and clinical applications in dental practice. Eur Radiol. 2010;20(11):2637ś55. doi:10.1007/s00330-010-1836-1.
  • 3. Akarslan Z. Dijital Intraoral Radyograőnin Dis Hekimligi Uygulamalarındaki Yeri: Dental Patolojilerde Teshis Etkinligi, Avantaj ve Dezavantajlari, Tercih Edilme Durumu. Turkiye Klinikleri J OralMaxillofac Radiol-Special Topics. 2016;2(2):29ś 34.
  • 4. Abubekir H. Agiz Dis ve Cene Radyolojisi. 2nd ed. İstanbul: Nobel Tip Kitabevleri; 2014.
  • 5. Korner M, Weber CH, Wirth S, Pfeifer KJ, Reiser MF, Treitl M. Advances in digital radiography: physical principles and system overview. Radiographics. 2007;27(3):675ś86. doi:10.1148/rg.273065075.
  • 6. Kurt H, Nalçacı R. Intraoral dijital goruntuleme sistemleri: Direkt sistemler, CCD, CMOS, duz panel dedektorler, indirekt sistemler, yarı direkt dijital goruntuleme, fosfor plak taramalari. Turkiye Klinikleri J Oral Maxillofac Radiol-Special Topics. 2016;2(2):4ś9.
  • 7. Parks ET. Digital radiographic imaging: is the dental practice ready? J Am Dent Assoc. 2008;139(4):477ś81. doi:10.14219/jada.archive.2008.0191.
  • 8. Borg E, Grondahl HG. On the dynamic range of different Xray photon detectors in intra-oral radiography. A comparison of image quality in őlm, charge-coupled device and storage phosphor systems. Dentomaxillofac Radiol. 1996;25(2):82ś8. doi:10.1259/dmfr.25.2.9446978.
  • 9. Haiter-Neto F, dos Anjos Pontual A, Frydenberg M, Wenzel A. Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-speciőc enhancement őlters. An ex vivo study in human teeth. Clin Oral Investig. 2008;12(3):217ś23. doi:10.1007/s00784-007-0173-5.
  • 10. Wenzel A, Moystad A. Work ŕow with digital intraoral radiography: a systematic review. Acta Odontol Scand. 2010;68(2):106ś 14. doi:10.3109/00016350903514426.
  • 11. Parks ET, Williamson GF. Digital radiography: an overview. J Contemp Dent Pract. 2002;3(4):23ś39.
  • 12. Soğur E, Baksi BG. İntraoral dijital görüntüleme sistemleri. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi. 2011;2011(3):249ś54.
  • 13. Ferreira LM, Queiroz PM, Santaella GM, Wenzel A, Groppo FC, Haiter-Neto F. The inŕuence of different scan resolutions on the detection of proximal caries lesions. Imaging Sci Dent. 2019;49(2):97ś102. doi:10.5624/isd.2019.49.2.97.
  • 14. Vandenberghe B, Bud M, Sutanto A, Jacobs R. The use of highresolution digital imaging technology for small diameter Kőle length determination in endodontics. Clin Oral Investig. 2010;14(2):223ś31. doi:10.1007/s00784-009-0285-1.
  • 15. Stuart C, White MJP. Oral Radiology: Principle and Interpretation. 7th ed. St. Louis, MO: Mosby. Elsevier; 2014.
  • 16. Wenzel A, Haiter-Neto F, Gotfredsen E. Inŕuence of spatial resolution and bit depth on detection of small caries lesions with digital receptors. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;103(3):418ś22. doi:10.1016/j.tripleo.2006.05.016.
  • 17. Lacerda MF, Junqueira RB, Lima TM, Lima CO, Girelli CF, Verner FS. Radiographic Diagnosis of Simulated External Root Resorption in Multi-Rooted Teeth: The Inŕuence of Spatial Resolution. Acta Odontol Latinoam. 2020;33(1):14ś21.
  • 18. de Moura G, Vizzotto MB, Tiecher P, Arus NA, Silveira H. Beneőts of using a photostimulable phosphor plate protective device. Dentomaxillofac Radiol. 2021;50(6):20200339. doi:10.1259/dmfr.20200339.
  • 19. Li G, Berkhout WE, Sanderink GC, Martins M, van der Stelt PF.Detection of in vitro proximal caries in storage phosphor plate radiographs scanned with different resolutions. Dentomaxillofac Radiol. 2008;37(6):325ś9. doi:10.1259/dmfr/62591340.
  • 20. Wenzel A, Kirkevang LL. High resolution charge-coupled device sensor vs. medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro. Dent Traumatol. 2005;21(1):32ś6. doi:10.1111/j.1600- 9657.2004.00258.x.
  • 21. Berkhout WE, Verheij JG, Syriopoulos K, Li G, Sanderink GC, van der Stelt PF. Detection of proximal caries with high-resolution and standard resolution digital radiographic systems. Dentomaxillofac Radiol. 2007;36(4):204ś10. doi:10.1259/dmfr/99904877.
  • 22. Nikneshan S, Abbas FM, Sabbagh S. Detection of proximal caries using digital radiographic systems with different resolutions. Indian J Dent Res. 2015;26(1):5ś10. doi:10.4103/0970- 9290.156787.
  • 23. de Oliveira ML, Pinto GC, Ambrosano GM, Tosoni GM. Effect of combined digital imaging parameters on endodontic őle measurements. J Endod. 2012;38(10):1404ś7. doi:10.1016/j.joen.2012.06.006.
APA TETİK H, Topal C, Ucok C (2023). Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. , 28 - 34. 10.52037/eads.2023.0007
Chicago TETİK HATİCE,Topal Ceyda Gizem,Ucok Cemile Ozlem Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. (2023): 28 - 34. 10.52037/eads.2023.0007
MLA TETİK HATİCE,Topal Ceyda Gizem,Ucok Cemile Ozlem Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. , 2023, ss.28 - 34. 10.52037/eads.2023.0007
AMA TETİK H,Topal C,Ucok C Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. . 2023; 28 - 34. 10.52037/eads.2023.0007
Vancouver TETİK H,Topal C,Ucok C Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. . 2023; 28 - 34. 10.52037/eads.2023.0007
IEEE TETİK H,Topal C,Ucok C "Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems." , ss.28 - 34, 2023. 10.52037/eads.2023.0007
ISNAD TETİK, HATİCE vd. "Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems". (2023), 28-34. https://doi.org/10.52037/eads.2023.0007
APA TETİK H, Topal C, Ucok C (2023). Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. European annals of dental sciences (Online), 50(1), 28 - 34. 10.52037/eads.2023.0007
Chicago TETİK HATİCE,Topal Ceyda Gizem,Ucok Cemile Ozlem Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. European annals of dental sciences (Online) 50, no.1 (2023): 28 - 34. 10.52037/eads.2023.0007
MLA TETİK HATİCE,Topal Ceyda Gizem,Ucok Cemile Ozlem Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. European annals of dental sciences (Online), vol.50, no.1, 2023, ss.28 - 34. 10.52037/eads.2023.0007
AMA TETİK H,Topal C,Ucok C Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. European annals of dental sciences (Online). 2023; 50(1): 28 - 34. 10.52037/eads.2023.0007
Vancouver TETİK H,Topal C,Ucok C Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems. European annals of dental sciences (Online). 2023; 50(1): 28 - 34. 10.52037/eads.2023.0007
IEEE TETİK H,Topal C,Ucok C "Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems." European annals of dental sciences (Online), 50, ss.28 - 34, 2023. 10.52037/eads.2023.0007
ISNAD TETİK, HATİCE vd. "Evaluation of the Effect of Spatial Resolution on Image Quality in Phosphor Plate Systems". European annals of dental sciences (Online) 50/1 (2023), 28-34. https://doi.org/10.52037/eads.2023.0007