Yıl: 2023 Cilt: 5 Sayı: 2 Sayfa Aralığı: 136 - 143 Metin Dili: İngilizce DOI: 10.36519/idcm.2023.210 İndeks Tarihi: 05-07-2023

Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR

Öz:
Objective: Reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) is one of the time-saving, accurate, and cost-effective alternative methods to real-time polymer- ase chain reaction (RT-PCR). This study aimed to identify the robustness of a colorimetric RT-LAMP assay kit that we developed, detecting SARS-COV-2 viral RNA within 30 minutes using a primer set special to the N gene against RT-PCR, the gold standard. Materials and Methods: Both symptomatic and asymptomatic subjects were included from a single university hospital and the status of both RT-PCR and RT-LAMP assay results were compared, and the consistency of these two assays was analyzed. Results: We showed that the RT-LAMP and RT-PCR assay results confirmed 90% consistency. When we consider the epidemiologic, clinical, and radiologic evaluation, the consistency reached 97%. Conclusion: The results revealed that the colorimetric RT-LAMP assay was efficient, robust, and rapid to be used as in vitro diagnostic tool to display competitiveness compared with RT-PCR.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1 Thompson D, Lei Y. Mini review: Recent progress in RT- LAMP enabled COVID-19 detection. Sens Actuators Rep. 2020;2(1):100017. [CrossRef]
  • 2 Dudley DM, Newman CM, Weiler AM, Ramuta MD, Shortreed CG, Heffron AS, et al. Optimizing direct RT-LAMP to detect transmissible SARS-CoV-2 from primary nasopharyngeal swab samples. PLoS One. 2020;15(12):e0244882. [CrossRef]
  • 3 Corman VM, Landt O, Kaiser M, Molenkamp R, Meijer A, Chu DK, et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill. 2020;25(3):2000045. Erra- tum in: Euro Surveill. 2020;25(14): Erratum in: Euro Surveill. 2020;25(30): Erratum in: Euro Surveill. 2021;26(5). [CrossRef]
  • 4 Kitajima H, Tamura Y, Yoshida H, Kinoshita H, Katsuta H, Mat- sui C, et al. Clinical COVID-19 diagnostic methods: Compari- son of reverse transcription loop-mediated isothermal ampli- fication (RT-LAMP) and quantitative RT-PCR (qRT-PCR). J Clin Virol. 2021;139:104813. [CrossRef]
  • 5 Aoki MN, de Oliveira Coelho B, Góes LGB, Minoprio P, Durigon EL, Morello LG, et al. Colorimetric RT-LAMP SARS-CoV-2 diag- nostic sensitivity relies on color interpretation and viral load. Sci Rep. 2021;11(1):9026. [CrossRef]
  • 6 Schmid-Burgk JL, Schmithaus RM, Li D, Hollstein R, Ben- Shmuel A, Israeli O, et al. LAMP-Seq: Population-scale COVID-19 diagnostics using combinatorial barcoding. bioRxiv 2020.04.06.025635. [CrossRef]
  • 7 Nawattanapaiboon K, Pasomsub E, Prombun P, Wongbunmak A, Jenjitwanich A, Mahasupachai P, et al . Colorimetric reverse transcription loop-mediated isothermal amplification (RT- LAMP) as a visual diagnostic platform for the detection of the emerging coronavirus SARS-CoV-2. Analyst. 2021;146(2):471-7. [CrossRef]
  • 8 de Oliveira Coelho B, Sanchuki HBS, Zanette DL, Nardin JM, Morales HMP, Fornazari B, et al. Essential properties and pit- falls of colorimetric reverse transcription loop-mediated iso- thermal amplification as a point-of-care test for SARS-CoV-2 diagnosis. Mol Med. 2021;27(1):30. [CrossRef]
  • 9 Österdahl MF, Lee KA, Lochlainn MN, Wilson S, Douthwaite S, Horsfall R, et al. Detecting SARS-CoV-2 at point of care: prelim- inary data comparing loop-mediated isothermal amplification (LAMP) to polymerase chain reaction (PCR). BMC Infect Dis. 2020;20(1):783. [CrossRef]
  • 10 Parida M, Shukla J, Sharma S, Ranghia Santhosh S, Ravi V, Mani R, et al. Development and evaluation of reverse transcription loop-mediated isothermal amplification assay for rapid and real-time detection of the swine-origin influenza A H1N1 virus. J Mol Diagn. 2011;13(1):100-7. [CrossRef]
APA Erdem M, Andac A, Özketen A, Karahan G, Tozluyurt A, Palaz F, ALP A, Unal S (2023). Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. , 136 - 143. 10.36519/idcm.2023.210
Chicago Erdem Murat,Andac Ayse,Özketen Ahmet Çağlar,Karahan Gizem,Tozluyurt Abdullah,Palaz Fahreddin,ALP ALPASLAN,Unal Serhat Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. (2023): 136 - 143. 10.36519/idcm.2023.210
MLA Erdem Murat,Andac Ayse,Özketen Ahmet Çağlar,Karahan Gizem,Tozluyurt Abdullah,Palaz Fahreddin,ALP ALPASLAN,Unal Serhat Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. , 2023, ss.136 - 143. 10.36519/idcm.2023.210
AMA Erdem M,Andac A,Özketen A,Karahan G,Tozluyurt A,Palaz F,ALP A,Unal S Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. . 2023; 136 - 143. 10.36519/idcm.2023.210
Vancouver Erdem M,Andac A,Özketen A,Karahan G,Tozluyurt A,Palaz F,ALP A,Unal S Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. . 2023; 136 - 143. 10.36519/idcm.2023.210
IEEE Erdem M,Andac A,Özketen A,Karahan G,Tozluyurt A,Palaz F,ALP A,Unal S "Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR." , ss.136 - 143, 2023. 10.36519/idcm.2023.210
ISNAD Erdem, Murat vd. "Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR". (2023), 136-143. https://doi.org/10.36519/idcm.2023.210
APA Erdem M, Andac A, Özketen A, Karahan G, Tozluyurt A, Palaz F, ALP A, Unal S (2023). Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. Infectious diseases and clinical microbiology (Online), 5(2), 136 - 143. 10.36519/idcm.2023.210
Chicago Erdem Murat,Andac Ayse,Özketen Ahmet Çağlar,Karahan Gizem,Tozluyurt Abdullah,Palaz Fahreddin,ALP ALPASLAN,Unal Serhat Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. Infectious diseases and clinical microbiology (Online) 5, no.2 (2023): 136 - 143. 10.36519/idcm.2023.210
MLA Erdem Murat,Andac Ayse,Özketen Ahmet Çağlar,Karahan Gizem,Tozluyurt Abdullah,Palaz Fahreddin,ALP ALPASLAN,Unal Serhat Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. Infectious diseases and clinical microbiology (Online), vol.5, no.2, 2023, ss.136 - 143. 10.36519/idcm.2023.210
AMA Erdem M,Andac A,Özketen A,Karahan G,Tozluyurt A,Palaz F,ALP A,Unal S Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. Infectious diseases and clinical microbiology (Online). 2023; 5(2): 136 - 143. 10.36519/idcm.2023.210
Vancouver Erdem M,Andac A,Özketen A,Karahan G,Tozluyurt A,Palaz F,ALP A,Unal S Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR. Infectious diseases and clinical microbiology (Online). 2023; 5(2): 136 - 143. 10.36519/idcm.2023.210
IEEE Erdem M,Andac A,Özketen A,Karahan G,Tozluyurt A,Palaz F,ALP A,Unal S "Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR." Infectious diseases and clinical microbiology (Online), 5, ss.136 - 143, 2023. 10.36519/idcm.2023.210
ISNAD Erdem, Murat vd. "Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR". Infectious diseases and clinical microbiology (Online) 5/2 (2023), 136-143. https://doi.org/10.36519/idcm.2023.210