The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments

Öz:
Purpose: To evaluate the effects of cataract surgery with high and low fluidic parameters on individuals retinal thicknesses in early postoperative period. Material and Methods: The study included 64 eyes of 64 patients who underwent uncomplicated phacoemulsification surgery for senile cataract. The patients were randomized to phacoemulsification with low (32 eyes) and high fluidic parameters (32 eyes). In both groups, the amount of balanced salt solution used (ABS), cumulative dissipated energy (CDE) and surgical time were recorded. Macular segmentation analysis in the foveal and parafoveal area was performed with spectral-domain optical coherence tomography (OCT) before surgery and on days 7 and 30 after surgery, and the OCT Fast Macular Thickness program was used to measure the thickness of individual retinal layers in both groups. Results: The mean age of the patients in the low and high fluidic groups were 61.8±5.4 and 60.4±6.7 years, respectively. The mean CDE and surgical time were significantly higher in the group using low fluidic parameters, while the mean ABS was significantly higher in the high fluidic group. On day 7 after surgery, there was a significant increase in the thickness of the parafoveal inner nuclear layer in the patients group who underwent surgery at high fluidic parameters, while no significant difference was observed in the low fluidic groups. On the 30th day after surgery, a significant increase was observed in the thickness of the parafoveal outer nuclear and inner nuclear layers in both groups, and the change in this layers was significantly higher in the high fluidic group. Conclusion: This study shows that the increased intraocular pressure during surgery due to high bottle level may also have an effect in the pathophysiology of inner retinal layer thickening in addition to the role of surgical induced inflammation.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Bibliyografik
  • 1. Hoffman RS, Fine IH, Packer M. New phacoemulsification technology. Curr Opin Ophthalmol 2005; 16:38-43
  • 2. Mackool RJ, Brint SF. AquaLase: a new technology for cataract extraction. Curr Opin Ophthalmol 2004; 15:40-43
  • 3. Gimbel HV, da Reitz Pereira C. Advances in phacoemulsification equipment. Curr Opin Ophthalmol 2002; 13:30-32
  • 4. Verges C, Cazal J, Lavin C. Surgical strategies in patients with cataract and glaucoma. Curr Opin Ophthalmol 2005;16:44-52.
  • 5. Baradaran-Rafii A, Rahmati-Kamel M, Eslani M, Kiavash V, Karimian F. Effect of hydrodynamic parameters on corneal endothelial cell loss after phacoemulsification. J Cataract Refract Surg 2009; 35:732-7.
  • 6. Das S, Nanaiah SG, Kummelil MK, Nagappa S, Shetty R, Shetty BK. Effect of fluidics on corneal endothelial cell density, central corneal thickness, and central macular thickness after phacoemulsification with torsional ultrasound. Indian J Opht. 2015;63:641-4.
  • 7. Chang A, Fridberg A, Kugelberg M. Comparison of phacoemulsification cataract surgery with low versus standard fluidic settings and the impact on postoperative parameters. Eur J Ophthalmol. 2017;27:39-44.
  • 8. Spaide RF, Koizumi H, Pozzoni MC. Enhanced depth imaging spectral-domain optical coherence tomography. Am J Ophthalmol 2008;146:496-500.
  • 9. Nicholas S, Riley A, Patel H, NeveldsonB, Purdie G, Wells AP. Correlations between optical coherence tomography measurement of macular thickness and visual acuity after cataract extraction. Clin Exp Ophthalmol. 2006;34:124-9
  • 10. Falcão MS, Gonçalves NM, Freitas-Costa P, Beato JB, Rocha- Sousa A, Carneiro A, Brandão EM, Falcão-Reis FM. Choroidal and macular thickness changes induced by cataract surgery. Clin Ophthalmol. 2014;8:55-60
  • 11. Biro Z, Balla Z, Kovacs B. Change of foveal and perifoveal thickness measured by OCT after phacoemulsification and IOL implantation. Eye (Lond). 2008;22:8-12.
  • 12. Cagini C, Fiore T, Iaccheri B, Piccinelli F, Ricci MA, Fruttini D. Macular thickness measured by optical coherence tomography in a healthy population before and after uncomplicated cataract phacoemulsification surgery. Curr Eye Res. 2009;34:1036-41.
  • 13. Von Jagow B, Ohrloff C, Kohnen T. Macular thickness after uneventful cataract surgery determined by optical coherence tomography. GraefesArch Clin Exp Ophthalmol. 2007;245:1765- 71
  • 14. Zhou Y, Zhou M, Wang Y, Ben S, Gao M, Zhang S, Liu H, Sun X. Short-term changes in retinal vasculature and layer thickness after phacoemulsification surgery. Curr Eye Res. 2020;45:31-7.
  • 15. Pilotto E, Leonardi F, Stefanon G, Longhin E, Torresin T, Deganello D, Cavarzeran F, Miglionico G, Parrozzani R, Midena E. Early retinal and choroidal OCT and OCT angiography signs of inflammation after uncomplicated cataract surgery. Br J Ophthalmol. 2019;103:1001-7.
  • 16. Kurt A, Kılıç R. The Effects of Uncomplicated Cataract Surgery on Retinal Layer Thickness. J Ophthalmol. 2018;2018:7218639.
  • 17. Yu S, Frueh BE, Steinmair D, Ebneter A, Wolf S, Zinkernagel MS, Munk MR. Cataract significantly influences quantitative measurements on swept-source optical coherence tomography angiography imaging. PLoS ONE 2018;13:0204501.
  • 18. Xu H, Chen M, Forrester JV, Lois N. Cataract surgery induces retinal pro-inflammatory gene expression and protein secretion. Invest Ophthalmol Vis Sci 2011;52: 249-55.
  • 19. Wang M, Ma W, Zhao L, et al. Adaptive Müller cell responses to microglial activation mediate neuroprotection and coordinate inflammation in the retina. J Neuroinflammation 2011;8:173-91.
  • 20. Zhao Z, Wen W, Jiang C, Lu Y. Changes in macular vasculature after uncomplicated phacoemulsification surgery: Optical coherence tomography angiography study. J Cataract Refract Surg. 2018;44:453-8.
  • 21. Miyake K, Ibaraki N. Prostaglandins and cystoid macular edema. Surv Ophthalmol 2002;47:203-18.
  • 22. Nagy ZZ, Ecsedy M, Kovács I, Takács A, Tátrai E, Somfai GM, DeBuc DC. Macular morphology assessed by optical coherence tomography image segmentation after femtosecond laser- assisted and standard cataract surgery. J Cataract Refract Surg. 2012;38:941-6.
  • 23. Schicke SH, Krumeich J, Duncker GIW, Scheibel S, Thielscher M. Retinal colour duplex scanning during LASIK-ring suction with different keratomes. Graefes Arch Clin Exp Ophthalmol. 2008;246:1009-15.
  • 24. Chen SN, Hwang JF, Chen YT. Macular thickness measurements in central retinal artery occlusion by optical coherence tomography. Retina. 2011;31:730-7.
  • 25. Hayreh SS, Jonas JB. Optic disc and retinal nerve fiber layer damage after transient central retinal artery occlusion: an experimental study in rhesus monkeys. Am J Ophthalmol. 2000;129:786-95.
  • 26. Evaluation of Fluidic Management Systems by Measuring the Dynamic IOP Fluctuations During Phacoemulsification. XXV Congress of the European Society of Cataract &Refractive Surgeons, Stockholm, Sweden, September 2007
  • 27. Vasavada AR, Praveen MR, Vasavada VA, Vasavada VA, Raj SM, Asnani PK, Garg VS. Impact of high and low aspiration parameters on postoperative outcomes of phacoemulsification: Randomized clinical trial. J Cataract Refract Surg. 2010;36:588- 93.
APA ALTUNEL O, gültekin irgat s, koç a, Oruç M, ÇAKAR E, Ozcura F (2023). The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. , 92 - 98. 10.37844/glau.cat.2023.18.13
Chicago ALTUNEL ORHAN,gültekin irgat saadet,koç alpaslan,Oruç Mehmet şefik,ÇAKAR EMİNE,Ozcura Fatih The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. (2023): 92 - 98. 10.37844/glau.cat.2023.18.13
MLA ALTUNEL ORHAN,gültekin irgat saadet,koç alpaslan,Oruç Mehmet şefik,ÇAKAR EMİNE,Ozcura Fatih The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. , 2023, ss.92 - 98. 10.37844/glau.cat.2023.18.13
AMA ALTUNEL O,gültekin irgat s,koç a,Oruç M,ÇAKAR E,Ozcura F The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. . 2023; 92 - 98. 10.37844/glau.cat.2023.18.13
Vancouver ALTUNEL O,gültekin irgat s,koç a,Oruç M,ÇAKAR E,Ozcura F The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. . 2023; 92 - 98. 10.37844/glau.cat.2023.18.13
IEEE ALTUNEL O,gültekin irgat s,koç a,Oruç M,ÇAKAR E,Ozcura F "The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments." , ss.92 - 98, 2023. 10.37844/glau.cat.2023.18.13
ISNAD ALTUNEL, ORHAN vd. "The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments". (2023), 92-98. https://doi.org/10.37844/glau.cat.2023.18.13
APA ALTUNEL O, gültekin irgat s, koç a, Oruç M, ÇAKAR E, Ozcura F (2023). The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. Glokom Katarakt, 18(2), 92 - 98. 10.37844/glau.cat.2023.18.13
Chicago ALTUNEL ORHAN,gültekin irgat saadet,koç alpaslan,Oruç Mehmet şefik,ÇAKAR EMİNE,Ozcura Fatih The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. Glokom Katarakt 18, no.2 (2023): 92 - 98. 10.37844/glau.cat.2023.18.13
MLA ALTUNEL ORHAN,gültekin irgat saadet,koç alpaslan,Oruç Mehmet şefik,ÇAKAR EMİNE,Ozcura Fatih The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. Glokom Katarakt, vol.18, no.2, 2023, ss.92 - 98. 10.37844/glau.cat.2023.18.13
AMA ALTUNEL O,gültekin irgat s,koç a,Oruç M,ÇAKAR E,Ozcura F The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. Glokom Katarakt. 2023; 18(2): 92 - 98. 10.37844/glau.cat.2023.18.13
Vancouver ALTUNEL O,gültekin irgat s,koç a,Oruç M,ÇAKAR E,Ozcura F The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments. Glokom Katarakt. 2023; 18(2): 92 - 98. 10.37844/glau.cat.2023.18.13
IEEE ALTUNEL O,gültekin irgat s,koç a,Oruç M,ÇAKAR E,Ozcura F "The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments." Glokom Katarakt, 18, ss.92 - 98, 2023. 10.37844/glau.cat.2023.18.13
ISNAD ALTUNEL, ORHAN vd. "The Impact of Cataract Surgery with Low and High Fluidic Settings on Different Retinal Segments". Glokom Katarakt 18/2 (2023), 92-98. https://doi.org/10.37844/glau.cat.2023.18.13