Yıl: 2012 Cilt: 36 Sayı: 4 Sayfa Aralığı: 593 - 600 Metin Dili: İngilizce İndeks Tarihi: 29-07-2022

Determination of lidocaine based on electrocatalysis of a chemically modified electrode

Öz:
The potential application of biochemically modified electrodes was investigated for construction of a drug biosensor. The electrocatalytic response of lidocaine was examined through modified electrodes using the electron transfer ability of hemoglobin (Hb) immobilized on gold film modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA). According to the results of voltammetric studies, Au/MPA/Hb electrodes exhibited high sensitivity and good electrocatalytic activity for the reduction of lidocaine, motivating us to construct drug biosensors. With this study, a new electroanalytical procedure is proposed for the determination of lidocaine level in medical applications or therapeutic formulations containing lidocaine as the active ingredient.
Anahtar Kelime:

Konular: Mühendislik, Kimya
Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Herrick, M.; Van Rooyen, I. F. Surgery (Oxford) 2002, 20, 67-72.
  • 2. Rahn, R.; Ball, B. Local Anesthesia in Dentistry, 3M ESPE AG, ESPE Platz, Seefeld, 2001.
  • 3. Becker, D. E.; Reed, K. L. Anesth. Prog. 2006, 53, 98-108.
  • 4. Tsirlis, A.; Karanikola, T.; Dabarakis, N.; Liverdos, K.; Charisi, M. Res. J. Pharmacol. 2010, 4, 1-4.
  • 5. Hakim, O. M.; El-Hag, Y. G.; Haikal, M. A. J. AAPOS. 2005, 9, 279-284.
  • 6. Yazici, F. G.; Arslan, M.; Birbicer, H.; Kanik, A.; Aban, M.; Oral, U. Pain Clinic 2003, 15, 339-343.
  • 7. Fukayama, H.; Suzuki, N.; Umino, M. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod. 2002, 94, 157-161.
  • 8. McLureand, H. A.; Rubin, A. P. Minerva Anestesiol. 2005, 71, 59-74.
  • 9. Hiller, A.; Karjalainen, K.; Rosenberg, P. Br. J. Anaesth. 1999, 82, 575-579.
  • 10. Keenaghan, J. B. Anesthesiology 1968, 29, 110-112.
  • 11. Ruzafa, A.; Pastor, M. C.; Aguilar, J. L.; Galimany, R. J. Liq. Chrom. 1991, 14, 2937-2949.
  • 12. Mo, Z. H.; Lou, J.; Long, X. H.; Xia, Z. L. Fresenius’ J. Anal. Chem. 1997, 358, 556-558.
  • 13. Ohshima, T.; Takayasu, T. J. Chromatogr. B Biomed. Sci. Appl. 1999, 726, 185-194.
  • 14. Luo, Y.; McNamara, B.; Fennell, M. A.; Teleis, D. C.; May, L.; Rudy, J.; Watson, A. O.; Uboh, C. E.; Soma, L. R. J. Chromatogr. B Biomed. Sci. Appl. 1998, 714, 269-276.
  • 15. Williamson, J. A.; Lieder, P. H.; Amegashitsi, L. J. Anal. Toxicol. 1995, 19, 256-260.
  • 16. Smith, D. J. J. Chromatogr. Sci. 1981, 19, 253-258.
  • 17. Zhang, X.; Zhao, D.; Feng, L.; Lia, L.; Wang, S. Mikrochim Acta 2010, 169, 153-159.
  • 18. Kulapina, E. G.; Barinova, O. V. Russ. J. Electrochem. 2001, 37, 803-807.
  • 19. Kulapina, E. G.; Barinova, O. V. J. Anal. Chem. 2001, 56, 457-460.
  • 20. Halbert, M. K.; Baldwin, R. P. J. Chromatogr. B Biomed. Sci. Appl. 1984, 306, 269-277.
  • 21. Sun, H.; Li, L.; Su, M.; Chromatographia 2008, 67, 399-405.
  • 22. Ding, S. N.; Xu, J. J.; Zhang, W. J.; Chen, H. Y. Talanta 2006, 70, 572-577.
  • 23. Oliveira, R. T. S.; Salazar-Banda, G. R.; Ferreira, V. S.; Oliveira, S. C.; Avaca, L. A. Electroanalysis 2007, 19, 1189-1194.
  • 24. Peng, L.; Yang, X.; Zhang, Q.; Liu, S. Electroanalysis 2008, 20, 803-807.
  • 25. Lu, Q.; Li, C. M. Biosens. Bioelectron. 2008, 24, 767-772.
  • 26. Song, J.; Xu, J.; Zhao, P.; Lu, L.; Bao, J. Microchimica Acta, 2011, 172, 117-123.
  • 27. Zhang, R.; Wang, X.; Shiu, K. K. J. Colloid Interface Sci. 2007, 316, 517-522.
  • 28. Wang, J.; Liang, Z.; Wang, L.; Fan, C.; Li, G. Sens. Actuators B Chem. 2007, 125, 17-21.
  • 29. Zeng, X.; Wei, W.; Li, X.; Zeng, J.; Wu, L. Bioelectrochemistry 2007, 71, 135-141.
  • 30. ElKaoutit, M.; Naranjo-Rodriguez, I.; Temsamani, K. R.; Dom´ınguez, M.; Hidalgo-Hidalgo de Cisneros, J. L. Talanta 2008, 75, 1348-1355.
  • 31. Li, H.; Liu, S.; Dai, Z.; Bao, J.; Yang, X. Sensors 2009, 9, 8547-8561.
  • 32. Ma, W.; Song, W.; Tian, D. B. Chin. Chem. Lett. 2009, 20, 358-361.
  • 33. Pingarr´on, J. M.; Y´a˜nez-Sede˜no, P.; Gonz´alez-Cort´es, A. Electrochimica Acta 2008, 53, 5848-5866.
  • 34. Zhao, Z.; Lei, W.; Zhang, X.; Wang, B.; Jiang, H. Sensors 2010, 10, 1216-1231.
  • 35. Chen, Y.; Yang, X. J.; Guo, L. R.; Li, J.; Xia, X. H.; Zheng, L. M. Anal. Chim. Acta 2009 644, 83-89.
  • 36. Wang, L.; Hu, N. Bioelectrochemistry 2001, 53, 205-212.
  • 37. Yang, J.; Hu, N. Bioelectrochem. Bioenerg. 1999, 48, 117-127.
  • 38. Fan, C.; Li, G.; Zhu, J.; Zhu, D. A. Anal. Chim. Acta 2000, 423, 95-100.
  • 39. Cheng, W.; Jin, G.; Zhang, Y. Sens. Actuators B Chem. 2006, 114, 40-46.
  • 40. Milhazes, N.; Martins, P.; Uriarte, E.; Garrido, J.; Calheiros, R.; Marques, M. P. M.; Borges, F. Anal. Chim. Acta 2007, 596, 231-241.
  • 41. Shoji, R.; Takeuchi, T.; Kubo, I. Anal. Chem. 2003, 75, 4882-4886.
  • 42. Li, X.; Zheng, W.; Zhang, L.; Yu, P.; Lin, Y.; Su, L.; Mao, L. Anal. Chem. 2009, 81, 8557-8563.
  • 43. Mai, Z.; Zhao, X.; Dai, Z.; Zou, X. Talanta 2010, 81, 167-175.
  • 44. Shahrokhian, S.; Ghalkhani, M. Electroanalysis 2008, 20, 1061-1066.
  • 45. Guo, C.; Hu, F.; Li, C. M.; Shen, P. K. Biosens. Bioelectron. 2008, 24, 819-824.
  • 46. Dogan-Topal, B.; Ozkan, S.A.; Uslu, B. Open Chem. Biomed. Meth. J. 2010, 3, 56-73.
APA Tan G, BOLAT G, ONUR M, ABACI S (2012). Determination of lidocaine based on electrocatalysis of a chemically modified electrode. , 593 - 600.
Chicago Tan Gamze,BOLAT GÜLÇİN,ONUR MEHMET ALİ,ABACI Serdar Determination of lidocaine based on electrocatalysis of a chemically modified electrode. (2012): 593 - 600.
MLA Tan Gamze,BOLAT GÜLÇİN,ONUR MEHMET ALİ,ABACI Serdar Determination of lidocaine based on electrocatalysis of a chemically modified electrode. , 2012, ss.593 - 600.
AMA Tan G,BOLAT G,ONUR M,ABACI S Determination of lidocaine based on electrocatalysis of a chemically modified electrode. . 2012; 593 - 600.
Vancouver Tan G,BOLAT G,ONUR M,ABACI S Determination of lidocaine based on electrocatalysis of a chemically modified electrode. . 2012; 593 - 600.
IEEE Tan G,BOLAT G,ONUR M,ABACI S "Determination of lidocaine based on electrocatalysis of a chemically modified electrode." , ss.593 - 600, 2012.
ISNAD Tan, Gamze vd. "Determination of lidocaine based on electrocatalysis of a chemically modified electrode". (2012), 593-600.
APA Tan G, BOLAT G, ONUR M, ABACI S (2012). Determination of lidocaine based on electrocatalysis of a chemically modified electrode. Turkish Journal of Chemistry, 36(4), 593 - 600.
Chicago Tan Gamze,BOLAT GÜLÇİN,ONUR MEHMET ALİ,ABACI Serdar Determination of lidocaine based on electrocatalysis of a chemically modified electrode. Turkish Journal of Chemistry 36, no.4 (2012): 593 - 600.
MLA Tan Gamze,BOLAT GÜLÇİN,ONUR MEHMET ALİ,ABACI Serdar Determination of lidocaine based on electrocatalysis of a chemically modified electrode. Turkish Journal of Chemistry, vol.36, no.4, 2012, ss.593 - 600.
AMA Tan G,BOLAT G,ONUR M,ABACI S Determination of lidocaine based on electrocatalysis of a chemically modified electrode. Turkish Journal of Chemistry. 2012; 36(4): 593 - 600.
Vancouver Tan G,BOLAT G,ONUR M,ABACI S Determination of lidocaine based on electrocatalysis of a chemically modified electrode. Turkish Journal of Chemistry. 2012; 36(4): 593 - 600.
IEEE Tan G,BOLAT G,ONUR M,ABACI S "Determination of lidocaine based on electrocatalysis of a chemically modified electrode." Turkish Journal of Chemistry, 36, ss.593 - 600, 2012.
ISNAD Tan, Gamze vd. "Determination of lidocaine based on electrocatalysis of a chemically modified electrode". Turkish Journal of Chemistry 36/4 (2012), 593-600.