Yıl: 2018 Cilt: 25 Sayı: 2 Sayfa Aralığı: 184 - 188 Metin Dili: İngilizce DOI: 10.5455/jtomc.2018.01.08 İndeks Tarihi: 27-03-2019

Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience

Öz:
Aim: Maintaining euvolemia is an important purpose in patients on hemodialysis therapy. Multiple-frequency bioimpedancespectroscopy (BIS) appears to be a useful and appropriate technique for assessing hydration status and body composition inhemodialysis patients.The aims of this study were to determine the pre and post hemodialysis hydration status of the pediatric hemodialysis patients by BIS and compare the dry weight determined by BIS to established by clinically.Material and Methods: Body Composition Monitor (BCM; Fresenius Medical Care, Germany) was performed in 13 pediatrichemodialysis patients in a single center. Patients were measured at the midweek session, once immediately before and once 30minutes after dialysis. Pre-and post-HD weights, blood pressures, were collected on the day of the BCM measurements.Results: Seven (53.8%) of the 13 patients were male and 6 (46.2%) were female. The mean age ranged from 11.92 ± 3.13 (5.7-16)years and duration time ranged from 7 to 54 months, and the median duration of dialysis was 11 months. Dry weights which wasdetermined clinically were higher than those calculated by BCM. A significant difference was found between mean values (34,71 ±12,68 versus 33,71 ± 12,16 kg, Δ: 1 ± 1,51, p = 0.035). There was a high positive correlation between dry weights measured by BCMand dry weight established by nephrologists (r = 0.993, p <0.001).Conclusion: In assessing dry weight, BCM appears to be a quick and easy-to-use tool that can assist the clinician in hemodialysistreatment and optimizing patient outcomes
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • Wizemann V, Wabel P, Chamney PW, Zaluska W, Moissl UM, Rode C, et al. The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant 2009;24(5):1574-9.
  • Mamat R, Kong NC, Ba’in A, Shah SA, Cader R, Wong V, et al. Assessment of body fluid status in hemodialysis patients using the body composition monitor measurement technique. J Clin Nurs 2012;21(19-20):2879-85.
  • Devolder I, Verleysen A, Vijt D, Vanholder R, Van Biesen W. Body composition, hydration, and related parameters in hemodialysis versus peritoneal dialysis patient. Perit Dial Int 2010;30(2):208-14.
  • Spiegel DM, Bashir K, Fish B. Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis. Clin Nephrol 2000;53(2):108-14.
  • Mendley SR, Majkowski NL, Schoeller DA. Validation of estimates of total body water in pediatric dialysis patients by deuterium dilution. Kidney Int 2005;67(5):2056-62.
  • Oh G, Wong C, Begin B, Salsbery K, Sutherland S, Chaudhuri A. Whole-body single-frequency bioimpedance analysis in pediatric hemodialysis patients. Pediatr Nephrol 2014;29(8):1417-23.
  • Milani GP, Groothoff JW, Vianello FA, Fossali EF, Paglialonga F, Edefonti A, et al. Bioimpedance and Fluid Status in Children and Adolescents Treated With Dialysis. Am J Kidney Dis 2017;69(3):428-435.
  • Zaloszyc A, Schaefer B, Schaefer F, Krid S, Salomon R, Niaudet P, et al. Hydration measurement by bioimpedance spectroscopy and blood pressure management in children on hemodialysis. Pediatr Nephrol 2013;28(11):2169-77.
  • Caravaca F, Martínez del Viejo C, Villa J, Martínez Gallardo R, Ferreira F. Hydration status assessment by multi-frequency bioimpedance in patients with advanced chronic kidney disease. Nefrologia 2011;31(5):537-44.
  • Mulasi U, Kuchnia AJ, Cole AJ, Earthman CP. Bioimpedance at the bedside: current applications, limitations, and opportunities. Nutr Clin Pract 2015;30(2):180-93.
  • Abbas SR, Liu L, Sipahioglu MH, Rosales L, Carter M, Kotanko P, et al. Comparison of bioimpedance techniques to detect changes in fluid status in hemodialysis patients. Blood Purif 2014;37(1):48-56.
  • Jaffrin MY, Morel H. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods. Med Eng Phys 2008;30(10):1257-69.
  • Chamney PW, Krämer M, Rode C, Kleinekofort W, Wizemann V. A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance. Kidney Int 2002;61(6):2250-8.
  • Katzarski K, Charra B, Laurent G, Lopot F, Divino-Filho JC, Nisell J, et al. Multifrequency bioimpedance in assessment of dry weight in haemodialysis. Nephrol Dial Transplant 1996;11(Suppl 2):20-3.
  • Wabel P, Chamney P, Moissl U, Jirka T. Importance of wholebody bioimpedance spectroscopy for the management of fluid balance. Blood Purif 2009;27(1):75-80.
  • Kyle UG, Bosaeus I, De Lorenzo AD, Deurenberg P, Elia M, Gómez JM, et al. Bioelectrical impedance analysis--part I: review of principles and methods. Clin Nutr 2004;23(5):1226-43.
  • Haroun D, Croker H, Viner RM, Williams JE, Darch TS, Fewtrell MS, et al. Validation of BIA in obese children and adolescents and re-evaluation in a longitudinal study. Obesity (Silver Spring) 2009;17(12):2245-50.
  • Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, Bosy-Westphal A, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas 2006;27(9):921-33.
  • Lukaski HC. Methods for the assessment of human body composition: traditional and new. Am J Clin Nutr 1987;46(4):537-56.
  • Raimann J, Liu L, Tyagi S, Levin NW, Kotanko P. A fresh look at dry weight. Hemodial Int 2008;12(4):395-405.
  • Leunissen KM, Kouw P, Kooman JP, Cheriex EC, deVries PM, Donker AJ, et al. New techniques to determine fluid status in hemodialyzed patients. Kidney Int Suppl 1993; 41:50-6.
  • Dou Y, Zhu F, Kotanko P. Assessment of extracellular fluid volume and fluid status in hemodialysis patients: current status and technical advances. Semin Dial 2012;25(4):377-87.
  • Hoenich NA, Levin NW. Can technology solve the clinical problem of ‘dry weight’? Nephrol Dial Transplant 2003;18(4):647-50.
  • Charra B, Laurent G, Chazot C, Calemard E, Terrat JC, Vanel T, et al. Clinical assessment of dry weight. Nephrol Dial Transplant 1996;11(Suppl 2):16-9.
  • Jaeger JQ, Mehta RL. Assessment of dry weight in hemodialysis: an overview. J Am Soc Nephrol 1999;10(2):392-403.
  • Passauer J, Petrov H, Schleser A, Leicht J, Pucalka K. Evaluation of clinical dry weight assessment in haemodialysis patients using bioimpedance spectroscopy: a crosssectional study. Nephrol Dial Transplant 2010;25(2):545-51.
  • Henderson LW. Symptomatic hypotension during hemodialysis. Kidney Int 1980;17(5):571-6.
  • Wabel P, Moissl U, Chamney P, Jirka T, Machek P, Ponce P, et al. Towards improved cardiovascular management: the necessity of combining blood pressure and fluid overload. Nephrol Dial Transplant 2008;23(9):2965-71.
  • Mitsnefes M, Stablein D. Hypertension in pediatric patients on long-term dialysis: a report of the North American Pediatric Renal Transplant Cooperative Study (NAPRTCS). Am J Kidney Dis 2005;42(2):309-15.
  • Stegmayr BG. Ultrafiltration and dry weight-what are the cardiovascular effects? Artif Organs 2003;27(3):227-9.
APA NALÇACIOĞLU H, ÖZKAYA O (2018). Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. , 184 - 188. 10.5455/jtomc.2018.01.08
Chicago NALÇACIOĞLU HÜLYA,ÖZKAYA Ozan Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. (2018): 184 - 188. 10.5455/jtomc.2018.01.08
MLA NALÇACIOĞLU HÜLYA,ÖZKAYA Ozan Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. , 2018, ss.184 - 188. 10.5455/jtomc.2018.01.08
AMA NALÇACIOĞLU H,ÖZKAYA O Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. . 2018; 184 - 188. 10.5455/jtomc.2018.01.08
Vancouver NALÇACIOĞLU H,ÖZKAYA O Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. . 2018; 184 - 188. 10.5455/jtomc.2018.01.08
IEEE NALÇACIOĞLU H,ÖZKAYA O "Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience." , ss.184 - 188, 2018. 10.5455/jtomc.2018.01.08
ISNAD NALÇACIOĞLU, HÜLYA - ÖZKAYA, Ozan. "Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience". (2018), 184-188. https://doi.org/10.5455/jtomc.2018.01.08
APA NALÇACIOĞLU H, ÖZKAYA O (2018). Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. Annals of Medical Research, 25(2), 184 - 188. 10.5455/jtomc.2018.01.08
Chicago NALÇACIOĞLU HÜLYA,ÖZKAYA Ozan Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. Annals of Medical Research 25, no.2 (2018): 184 - 188. 10.5455/jtomc.2018.01.08
MLA NALÇACIOĞLU HÜLYA,ÖZKAYA Ozan Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. Annals of Medical Research, vol.25, no.2, 2018, ss.184 - 188. 10.5455/jtomc.2018.01.08
AMA NALÇACIOĞLU H,ÖZKAYA O Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. Annals of Medical Research. 2018; 25(2): 184 - 188. 10.5455/jtomc.2018.01.08
Vancouver NALÇACIOĞLU H,ÖZKAYA O Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience. Annals of Medical Research. 2018; 25(2): 184 - 188. 10.5455/jtomc.2018.01.08
IEEE NALÇACIOĞLU H,ÖZKAYA O "Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience." Annals of Medical Research, 25, ss.184 - 188, 2018. 10.5455/jtomc.2018.01.08
ISNAD NALÇACIOĞLU, HÜLYA - ÖZKAYA, Ozan. "Assessment of bioelectrical impedance analysis for determining dry weight in pediatric hemodialysis patients; single center experience". Annals of Medical Research 25/2 (2018), 184-188. https://doi.org/10.5455/jtomc.2018.01.08