Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases

Öz:
Purpose: To compare preoperative 20 mHz ultrasonography (USG) fi ndings and intraoperative evaluation of the integrity of posterior lens capsuleand anterior hyaloid membrane.Materials and Methods: The study include 51 eyes of 51 patients with traumatic cataract. All patients evaluated with 20 mHz USG preoperativelyand scheduled to undergo cataract extraction. The 20 mHz USG scanning results were entitled as regular, defect and irregular. The intraoperativefi ndings were entitled as regular, aperture with no vitreous and aperture with vitreous.Results: The mean visual acuity of patients with a mean age of 42 ± 19 years (range, 12-82) was 2.3 ± 0.7 log MAR before the surgery. TwentymHz USG showed regularity of posterior lens capsule in 27 patients (%53), irregularity in 21 patients (%41) and defect in three patients (%6).However, the intraoperative evaluation indicated regularity in 30 patients (%59), aperture with vitreous in 19 patients (%37) and aperture with novitreous in two patients (%4). Comparison of the 20 mHz USG and intraoperative fi ndings showed sensitivity, specifi city, positive predictive valueand negative predictive value of %100(100-100), %90 (79.2-100), %87.5 (74.2-100), and %100 (100-100), respectively. Coeffi cient of concor-dance between two methods was 0.853 (0.613-1.093) and observed proportion of agreement was 0.922.Conclusions: In our study we indicated that both posterior lens capsule and anterior hyaloid membrane can be evaluated using 20 mHz USGscanning. Preoperative scanning with 20 mHz USG probe provides valuable informations especially in patients with traumatic cataract.
Anahtar Kelime:

Konular: Sağlık Politikaları ve Hizmetleri Göz Hastalıkları

Travmatik Kataraktlı Hastalarda Arka Lens Kapsülü ve Ön Hyaloid Membranın 20 MHz Ultrason Probu ile Değerlendirilmesi

Öz:
Amaç: Arka lens kapsülü ve ön hyaloid membranın bütünlüğünün intraoperatif değerlendirmesi ile preoperatif 20 mHz ultrasonografi (USG) bulgularını karşılaştırmak. Gereç ve Yöntemler: Çalışmaya travmatik kataraktlı 51 hastanın 51 gözü dahil edilmiştir. Tüm hastalar preoperatif olarak 20 mHz USG ile değerlendirilmiştir ve katarakt cerrahisi planlanmıştır. 20 mHz USG tarama sonuçları düzenli, defektif ve düzensiz olarak gruplandırılmıştır. İntraoperatif bulgular ise sağlam, vitresiz açıklık ve vitreli açıklık şeklinde gruplandırılmıştır. Bulgular: Yaş ortalaması 42 ± 19 (12-82 yaş) olan hastaların ortalama görme seviyesi cerrahi öncesi 2,3 ± 0,7 log MARdı. Yirmi mHz USG 27 hastada (%53) arka lens kapsülünün düzenli olduğunu gösterdi, 21 hastada (%41) düzensizlik mevcuttu ve 3 hastala (%6) defekt vardı. Bununla birlikte, intraoperatif değerlendirme hastaların 30’unda (%59) arka lens kapsülünün sağlam, 19’unda (%37) vitreli açıklık ve 2’sinde (%4) vitresiz açıklık mevcuttu. 20 mHz USG ve intraoperatif bulgular karşılaştırıldığında sensitivite, spesifi te, pozitif prediktif değer ve negatif prediktif değer sırasıyla %100 (100-100), %90 (79,2-100), %87,5 (74,2-100) ve %100 (100-100) olarak hesaplandı. Her iki metod arasındaki uyumluluk katsayısı 0,853 (0,613-1,093) ve gözlenen uyuşma oranı 0,922 olarak bulundu. Sonuç: Çalışmamızda hem arka lens kapsülünün hem de ön hyaloid membranın 20 mHz USG taramasıkullanılarak değerlendirilebildiğini göster- dik. 20 mHz USG ile preoperatif tarama özellikle travmatik kataraktlı hastalarda değerli bilgiler sağlar.
Anahtar Kelime:

Konular: Sağlık Politikaları ve Hizmetleri Göz Hastalıkları
Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Bibliyografik
  • Nguyen TN, Mansour M, Deschenes J et al. Visualization of posterior lens capsule integrity by 20 MHz Ultrasound Probe in Ocular Trauma. Am J Ophthalmol 2003; 136: 754-5.
  • Tabatabaei A, Kiarudi MY, Ghassemi F et al. Eval- uation of posterior lens capsule by 20-MHz ultra- sound probe in traumatic cataract. Am J Ophthalmol 2012; 153: 51-4.
  • Ozdal MP, Mansour M, Deschênes J. Ultrasound biomicro- scopic evaluation of the traumatized eyes. Eye (Lond). 2003; 17: 467-72.
  • Perry LJ. The evaluation of patients with traumatic cata- racts by ultrasound Technologies. Semin Ophthalmol. 2012; 27: 121-4.
  • Rosen WJ, Campbell DG. Posterior capsule rupture after a paint-pellet injury. J Cataract Refract Surg 2000; 26: 1422-3.
  • Pavlin CJ, Harasiewicz K, Sherar MD et al. Clinical use of ultrasound biomicroscopy. Ophthalmology 1991; 98: 287-95.
  • Skalka HW. Ultrasonic diagnosis of posterior lens rupture. Ophthalmic Surg. 1977; 72-6.
  • Shi B, Chen W. Clinical signifi cance of preoperative B-ultra- sonography for traumatic cataract. Zhonghua Yan Ke Za Zhi. 1998; 34: 298-9.
  • Silverman RH. High-resolution ultrasound imaging of the eye- a review. Clin Experiment Ophthalmol. 2009; 37: 54-67.
APA ÇETİNKAYA T, ARITÜRK N (2018). Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. , 7 - 10.
Chicago ÇETİNKAYA Tuğba,ARITÜRK Nurşen Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. (2018): 7 - 10.
MLA ÇETİNKAYA Tuğba,ARITÜRK Nurşen Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. , 2018, ss.7 - 10.
AMA ÇETİNKAYA T,ARITÜRK N Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. . 2018; 7 - 10.
Vancouver ÇETİNKAYA T,ARITÜRK N Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. . 2018; 7 - 10.
IEEE ÇETİNKAYA T,ARITÜRK N "Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases." , ss.7 - 10, 2018.
ISNAD ÇETİNKAYA, Tuğba - ARITÜRK, Nurşen. "Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases". (2018), 7-10.
APA ÇETİNKAYA T, ARITÜRK N (2018). Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. Glokom Katarakt, 13(1), 7 - 10.
Chicago ÇETİNKAYA Tuğba,ARITÜRK Nurşen Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. Glokom Katarakt 13, no.1 (2018): 7 - 10.
MLA ÇETİNKAYA Tuğba,ARITÜRK Nurşen Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. Glokom Katarakt, vol.13, no.1, 2018, ss.7 - 10.
AMA ÇETİNKAYA T,ARITÜRK N Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. Glokom Katarakt. 2018; 13(1): 7 - 10.
Vancouver ÇETİNKAYA T,ARITÜRK N Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases. Glokom Katarakt. 2018; 13(1): 7 - 10.
IEEE ÇETİNKAYA T,ARITÜRK N "Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases." Glokom Katarakt, 13, ss.7 - 10, 2018.
ISNAD ÇETİNKAYA, Tuğba - ARITÜRK, Nurşen. "Evaluation of Posterior Lens Capsule and Anterior Hyaloid Membrane Using 20 MHz-Ultrasound Probe in Traumatic Cataract Cases". Glokom Katarakt 13/1 (2018), 7-10.