Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome

Öz:
A 7-year-old girl (height, 94 cm; weight, 15.1 kg) with Downsyndrome was scheduled for right patellar dislocation repositioning.The ultrasonographically measured internal transverse widthof the cricoid before intubation was 7.8 mm. Attempted insertionof a cuffed Mallinckrodt® endotracheal tube (ETT) (internal diameter,5.0 mm; deflated cuff portion, 8.4 mm diameter) failed.In contrast, the insertion of a cuffed Microcuff® ETT (5.0 mm ID;deflated cuff portion, 7.3 mm diameter) was successful. Thickerfolds in the deflated cuff of the Mallinckrodt ETT could havehindered passage through the vocal cord, including the cricoidregion. It is becoming standard to use the ultrasonographicallymeasured internal width of the cricoid when choosing cuffed paediatricETTs, and this approach may be suitable for patients withDown syndrome as well. In these children, approximately 20%of uncuffed ETTs inserted were one or two sizes smaller in diameterthan those predicted for the same age. We may choose theETT size in reference to an ultrasonographically obtained internaltransverse width of the cricoid, stated outer diameter (OD) by theproducer, and the actual OD depending on the cuff bulk insteadof a tube size calculation in patients with growth retardation.
Anahtar Kelime:

Konular: Anestezi

Down Sendromu Olan Bir Çocukta Krikoid Ultrasonu Kullanılarak Uygun Bir Kaflı Endotrakeal Tüpün Seçilmesi

Öz:
Yedi yaşındaki (boy: 94 cm, ağırlık: 15,1 kg) Down sendromlu bir kız çocuğu için, sağ patellar dislokasyon repozisyonu planlandı. Entübasyon öncesinde ultrasonografik olarak ölçülen internal transvers krikoid genişliği 7,8 mm idi. Kaflı Mallinckrodt® endotrakeal tüp (ETT) (iç çap, 5,0 mm; sönük kaf çapı 8,4 mm) uygulama denemesi başarısız oldu. Ancak, kaflı Microcuff® ETT (5,0 mm iç çap; sönük kaf çapı, 7,3 mm) başarıyla yerleştirildi. Mallinckrodt ETT’nin sönük kafındaki daha kalın katlar, krikoid bölgesi de dahil vokal korttan geçişi engellemiş olabilir. Kaflı pediatrik ETT’leri seçerken ultrasonografik olarak ölçülen internal transvers krikoid genişliğinin kullanılması standartlaşmaktadır ve bu yaklaşım Down sendromlu hastalar için de uygun olabilir. Bu çocuklarda yerleştirilen kafsız ETT’lerin yaklaşık %20’si, aynı yaştaki diğer çocuklar için öngörülenlerden, çap olarak bir ya da iki ebat daha küçüktü. Gelişme geriliği olan hastalarda ETT büyüklüğünü ultrasonografik olarak elde edilen internal transvers krikoid genişliği, üretici tarafından belirtilen dış çap (DÇ) ve tüp ebatı hesaplaması yerine kaf kütlesine bağlı olarak gerçek DÇ’a göre seçebiliriz.
Anahtar Kelime:

Konular: Anestezi
Belge Türü: Makale Makale Türü: Olgu Sunumu Erişim Türü: Erişime Açık
  • 1. Rafiq M, Wani TM, Moore-Clingenpeel M, Tobias JD. Endotracheal tubes and the cricoid: is there a good fit? Int J Pediatr Otorhinolaryngol 2016; 90: 70. [CrossRef ]
  • 2. Shibasaki M, Nakajima Y, Ishii S, Shimizu F, Shime N, Sessler DI. Prediction of pediatric endotracheal tube size by ultrasonography. Anesthesiology 2010; 113: 819-24. [CrossRef ]
  • 3. Altun D, Sungur MO, Ali A, Bingül ES, Seyhan TÖ, Çamcı E. Ultrasonographic measurement of subglottic diameter for paediatric cuffed endotracheal tube size selection: feasibility report. Turk J Anaesthesiol Reanim 2016; 44: 301-5. [CrossRef ]
  • 4. Imai K, Doi T, Kayashima K. Difficulty inserting cuffed endotracheal tubes in a child. A A Case Rep 2017; 8: 129-31. [CrossRef ]
  • 5. Motoyama EK. Induction of anesthesia and maintenance of the airway in infants and children. In: Motoyama EK, Davis PJ, editors. Smith’s Anesthesia for Infants and Children. 7th ed. St. Louis: CV Mosby; 2006. p. 336. [CrossRef ]
  • 6. Weiss M, Gerber AC, Dullenkopf A. Appropriate placement of intubation depth marks in a new cuffed paediatric tracheal tube. Br J Anaesth 2005; 94: 80-7. [CrossRef ]
  • 7. Kim EJ, Kim SY, Kim WO, Kim H, Kil HK. Ultrasound measurement of subglottic diameter and an empirical formula for proper endotracheal tube fitting in children. Acta Anaesthesiol Scand 2013; 57: 1124-30. [CrossRef ]
  • 8. Kobel M, Creighton RE, Steward DJ. Anaesthetic considerations in Down’s syndrome: experience with 100 patients and a review of the literature. Can Anaesth Soc J 1982; 29: 593-9. [CrossRef ]
  • 9. Shott SR. Down syndrome: analysis of airway size and a guide for appropriate intubation. Laryngoscope 2000; 110: 585-92. [CrossRef ]
  • 10. Litman RS, Weissend EE, Shibata D, Westesson PL. Development changes of laryngeal dimensions in unparalyzed, sedated children. Anesthesiology 2003; 98: 41-5. [CrossRef ]
  • 11. Dalal PG, Murray D, Messner AH, Feng A, McAllister J, Molter D. Pediatric laryngeal dimensions: an age-based analysis. Anesth Analg 2009; 108: 1475-9. [CrossRef ]
APA KAYASHİMA K, YAMASAKI R (2018). Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. , 323 - 325. 10.5152/TJAR.2018.87847
Chicago KAYASHİMA Kenji,YAMASAKI Ryo Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. (2018): 323 - 325. 10.5152/TJAR.2018.87847
MLA KAYASHİMA Kenji,YAMASAKI Ryo Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. , 2018, ss.323 - 325. 10.5152/TJAR.2018.87847
AMA KAYASHİMA K,YAMASAKI R Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. . 2018; 323 - 325. 10.5152/TJAR.2018.87847
Vancouver KAYASHİMA K,YAMASAKI R Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. . 2018; 323 - 325. 10.5152/TJAR.2018.87847
IEEE KAYASHİMA K,YAMASAKI R "Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome." , ss.323 - 325, 2018. 10.5152/TJAR.2018.87847
ISNAD KAYASHİMA, Kenji - YAMASAKI, Ryo. "Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome". (2018), 323-325. https://doi.org/10.5152/TJAR.2018.87847
APA KAYASHİMA K, YAMASAKI R (2018). Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. Turkish Journal of Anaesthesiology and Reanimation, 46(4), 323 - 325. 10.5152/TJAR.2018.87847
Chicago KAYASHİMA Kenji,YAMASAKI Ryo Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. Turkish Journal of Anaesthesiology and Reanimation 46, no.4 (2018): 323 - 325. 10.5152/TJAR.2018.87847
MLA KAYASHİMA Kenji,YAMASAKI Ryo Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. Turkish Journal of Anaesthesiology and Reanimation, vol.46, no.4, 2018, ss.323 - 325. 10.5152/TJAR.2018.87847
AMA KAYASHİMA K,YAMASAKI R Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. Turkish Journal of Anaesthesiology and Reanimation. 2018; 46(4): 323 - 325. 10.5152/TJAR.2018.87847
Vancouver KAYASHİMA K,YAMASAKI R Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome. Turkish Journal of Anaesthesiology and Reanimation. 2018; 46(4): 323 - 325. 10.5152/TJAR.2018.87847
IEEE KAYASHİMA K,YAMASAKI R "Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome." Turkish Journal of Anaesthesiology and Reanimation, 46, ss.323 - 325, 2018. 10.5152/TJAR.2018.87847
ISNAD KAYASHİMA, Kenji - YAMASAKI, Ryo. "Selecting an Appropriate Cuffed Endotracheal Tube Using Ultrasound of the Cricoid in a Child with Down Syndrome". Turkish Journal of Anaesthesiology and Reanimation 46/4 (2018), 323-325. https://doi.org/10.5152/TJAR.2018.87847