Yıl: 2018 Cilt: 34 Sayı: 4 Sayfa Aralığı: 255 - 257 Metin Dili: İngilizce DOI: DOI: 10.5152/eamr.2018.59862 İndeks Tarihi: 09-10-2020

Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates

Öz:
Objective: The aim of this study was to measure and report the pupillary diameter of myopic refractive surgery candidates and to identify the associated factors.Methods: This was a retrospective, descriptive, cross-sectional study. Consecutive patients withmyopia or myopic astigmatism were included in the study. Patients with accompanying ocular pathologies were excluded. Only one eye of the remaining patients was selected using a randomnumber table. Age, sex, spherical equivalent of manifest refraction (SE), and axial length (AL) wererecorded. Scotopic, mesopic, and photopic pupillary diameters were measured with dynamic pupillometery (Sirius, Schwind Eye Tech Solutions AG, Germany).Results: Eighty eyes of 80 patients were included in the study. The mean age of the patients was 28±6years, and mean SE was -5.25±2.26 D. The mean AL was 25.41±1.41 mm. The mean scotopic, mesopic,and photopic pupillary diameters were 6.26±0.60, 5.81±0.61, and 4.43±0.68 mm, respectively. SE andAL were not found to be correlated with pupillary size. The mesopic pupillary diameter was slightlyhigher in females than in males (5.98±0.50 vs. 5.62±0.68; Student t test; p=0.037). There was a statistically significant negative correlation between mesopic and scotopic pupillary diameters and age.Conclusion: This study investigated the pupillary diameters of myopic refractive surgery candidates and showed that age and sex are the most important determinants of pupillary diameter.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Haw WW, Manche EE. Effect of preoperative pupil measurements on glare, halos, and visual function after photoastigmatic refractive keratectomy. J Cataract Refract Surg 2001; 27: 907-16. [CrossRef]
  • 2. Holladay JT. The high cost of inaccurate pupillometry. Rev Ophthalmol 2002; 9: 47-9.
  • 3. Rosen E. The pupil and refractive surgery. In: Essential in Ophthalmology, Cataract and Refractive Surgery. Verlag Berlin Heidelberg: Springer, 2005; pp. 289-302. [CrossRef]
  • 4. Schallhorn SC, Kaupp SE, Tanzer DJ, Tidwell J, Laurent J, Bourque LB. Pupil size and quality of vision after LASIK. Ophthalmology 2003; 110: 1606-14. [CrossRef]
  • 5. Schmidt GW, Yoon M, McGwin G, Lee PP, McLeod SD. Evaluation of the relationship between ablation diameter, pupil size, and visual function with vision-specific quality-of-life measures after laser in situ keratomileusis. Arch Ophthalmol 2007; 125: 1037-42. [CrossRef]
  • 6. Çakmak HB, Cagil N, Simavli H, Duzen B, Simsek S. Refractive error may influence mesopic pupil size. Curr Eye Res 2010; 35: 130-6. [CrossRef]
  • 7. Altan C, Kaya V, Basarir B, Celik U, Azman E, Akar S, et al. Comparison of 3 pupillometers for determining scotopic pupil diameter. Eur J Ophthalmol 2012; 22: 904-10. [CrossRef]
  • 8. Bootsma S, Tahzib N, Eggink F, de Brabander J, Nuijts R. Comparison of two pupillometers in determining pupil size for refractive surgery. Acta Ophthalmol Scand 2007; 85: 324-8. [CrossRef]
  • 9. Cheng AC, Lam DS. Comparison of the Colvard pupillometer and the Zywave for measuring scotopic pupil diameter. J Refract Surg 2004; 20: 248-52.
  • 10. McDonnell C, Rolincova M, Venter J. Comparison of measurement of pupil sizes among the colvard pupillometer, procyon pupillometer, and NIDEK OPD-scan. J Refract Surg. 2006; 22: 1027-30.
  • 11. Schmitz S, Krummenauer F, Henn S, Dick HB. Comparison of three different technologies for pupil diameter measurement. Graefes Arch Clin Exp Ophthalmol 2003; 241: 472-77. [CrossRef]
  • 12. Wickremasinghe SS, Smith GT, Stevens JD. Comparison of dynamic digital pupillometry and static measurements of pupil size in determining scotopic pupil size before refractive surgery. J Cataract Refract Surg 2005; 31: 1171-6. [CrossRef]
  • 13. Winn B, Whitaker D, Elliott DB, Phillips NJ. Factors affecting lightadapted pupil size in normal human subjects. Invest Ophthalmol Vis Sci 1994; 35: 1132-7.
  • 14. Netto MV, Ambrósio R, Wilson SE. Pupil size in refractive surgery candidates. J Refract Surg 2004; 20: 337-42.
  • 15. Jones R. Do women and myopias have larger pupils? Invest Ophthalmol Vis Sci 1990; 31: 1413-5.
APA Demircan A, demirok a (2018). Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. , 255 - 257. DOI: 10.5152/eamr.2018.59862
Chicago Demircan Ali,demirok ahmet Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. (2018): 255 - 257. DOI: 10.5152/eamr.2018.59862
MLA Demircan Ali,demirok ahmet Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. , 2018, ss.255 - 257. DOI: 10.5152/eamr.2018.59862
AMA Demircan A,demirok a Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. . 2018; 255 - 257. DOI: 10.5152/eamr.2018.59862
Vancouver Demircan A,demirok a Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. . 2018; 255 - 257. DOI: 10.5152/eamr.2018.59862
IEEE Demircan A,demirok a "Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates." , ss.255 - 257, 2018. DOI: 10.5152/eamr.2018.59862
ISNAD Demircan, Ali - demirok, ahmet. "Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates". (2018), 255-257. https://doi.org/DOI: 10.5152/eamr.2018.59862
APA Demircan A, demirok a (2018). Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. European Archives of Medical Research, 34(4), 255 - 257. DOI: 10.5152/eamr.2018.59862
Chicago Demircan Ali,demirok ahmet Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. European Archives of Medical Research 34, no.4 (2018): 255 - 257. DOI: 10.5152/eamr.2018.59862
MLA Demircan Ali,demirok ahmet Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. European Archives of Medical Research, vol.34, no.4, 2018, ss.255 - 257. DOI: 10.5152/eamr.2018.59862
AMA Demircan A,demirok a Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. European Archives of Medical Research. 2018; 34(4): 255 - 257. DOI: 10.5152/eamr.2018.59862
Vancouver Demircan A,demirok a Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates. European Archives of Medical Research. 2018; 34(4): 255 - 257. DOI: 10.5152/eamr.2018.59862
IEEE Demircan A,demirok a "Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates." European Archives of Medical Research, 34, ss.255 - 257, 2018. DOI: 10.5152/eamr.2018.59862
ISNAD Demircan, Ali - demirok, ahmet. "Dynamic Pupillometry in Myopia and Myopic Astigmatism Refractive Surgery Candidates". European Archives of Medical Research 34/4 (2018), 255-257. https://doi.org/DOI: 10.5152/eamr.2018.59862