Yıl: 2021 Cilt: 33 Sayı: 1 Sayfa Aralığı: 53 - 57 Metin Dili: İngilizce DOI: 10.7240/jeps.705202 İndeks Tarihi: 17-10-2021

Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit

Öz:
Energy needs and consumption in the world is increasing steadily. For this reason, the importance of reducing energy consumption and using energy more efficiently increases day by day. Hence, energy efficiency has great importance both economically and for the protection of nature.Heat recovery device is a system that needs ventilation and can be used to save energy (reduce energy consumption) in all areas of different temperatures (home, office, cinema, shopping mall, conference room, etc.) with the outdoor environment. This device can save a significant amount of energy from heating and cooling processes by transferring heat between the exhaust air and the fresh air.The most widely used type of this device is a plate heat exchanger. In this system, heat transfer is carried out without allowing to blend the egzost air and the fresh air. In this study, the aim is to increase the thermal efficiency of the device. The geometry of the heat exchanger was changed to increase the amount of heat transfer.For this purpose, the current model was created in computer environment and computer simulations were made through the ANSYS-Fluent program. Then the new models with different geometries were created in the computer environment and simulations were made on these models using the same method. The current model and the new models have been compared in terms of thermal efficiency.
Anahtar Kelime:

Havadan Havaya Plakalı Tip Isı Geri Kazanım Cihazlarında Isı Değiştiricisi Geometrisinin Isıl Verimlilik Üzerindeki Etkilerinin Sayısal Olarak İncelenmesi

Öz:
Dünyada enerji ihtiyacı ve tüketimi giderek artmaktadır. Bu sebep ile enerji tüketimini azaltmak ve enerjiyi daha verimlikullanılmak her geçen gün daha önem kazanmaktadır. Bu sebeple enerji verimliliği gerek ekonomik gerekse doğanın korunmasıaçısından büyük önem taşımaktadır.Isı geri kazanım cihazı, havalandırılma ihtiyacı olan, dış ortamla farklı sıcaklıktaki tüm mahallerde (ev, ofis, sinema, AVM, Konferans salonu vb.) enerji tasarrufu sağlamak (enerji tüketimini azaltmak) için kullanılabilen bir sistemdir. Bu cihaz dışarıatılacak hava ile iç ortama alınacak hava arasında ısı transferi yaparak, ısıtma ve soğutma işlemlerinden ciddi oranda tasarrufve enerji kazancı sağlayabilmektedir.Bu cihazın en yaygın kullanılan türü plakalı ısı değiştiricili olanıdır. Bu sistemde ısı transferi dışarı atılan kirli hava ile içerialınan temiz hava arasında 2 havanın karışmasına izin verilmeden yapılmaktadır. Bu çalışmada cihazın, ısıl verimliliğininartırılması amaçlanmıştır. Bunun için kullanılan ısı değiştiricisinin geometrisi değiştirilerek ısı transferi artırılmak istenmiştir. Bunun için mevcut olan model sanal ortamda (bilgisayar ortamında) oluşturularak, ANSYS-Fluent programı vasıtasıylabilgisayar benzetimleri (simülasyonları) yapılmıştır. Sonrasında bilgisayar ortamında farklı geometrilere sahip yeni modelleroluşturulmuş ve aynı metot kullanılarak bu modeller üzerinde benzetimler (simülasyonlar) yapılmıştır. Yeni modellerin mevcutmodel ile ısıl verimleri karşılaştırılmıştır.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • [1] Bayraç, H. N. (2010). Enerji Kullanımının Küresel Isınmaya Etkisi ve Önleyici Politikalar. Eskişehir Osmangazi Üniversitesi Sosyal Bilimler Dergisi, 11(2), 229-259.
  • [2] Pamir, N. (2005). Enerji Politikalar ve Küresel Gelişmeler. Stratejik Analiz, 6(68).
  • [3] Narin, M., & Akdemir, S. (2006). Enerji verimliliği ve Türkiye. Türkiye Ekonomik Kurumu UEK-TEK.
  • [4] Satman, A. (2007). Türkiye’nin enerji vizyonu. VIII. Ulusal Tesisat Mühendisliği Kongresi, (s 3), 18.
  • [5] Şahan, A. M. Isı Geri Kazanım Eşanjörlerinin Kullanım Opsiyonları.
  • [6] Şentürk, U., Altın, M., Ağar, G., Aktakka, S., & Toksoy, M. (2015). Bir Isı Geri Kazanım Cihazının Performans Karakteristiklerinin Deneysel ve Sayısal Olarak Belirlenmesi. Engineer & the Machinery Magazine, 56(667).
  • [7] Altın, M., Aktakka, S., Günerhan, H. & Karakoç, T.H. (2013). Farklı İklim Bölgelerine Ait IsıtmaSoğutma Tasarım Sıcaklıklarının Dikkate Alınarak Bir Isı Geri Kazanım Sisteminin Tasarımı. 11. Ulusal Tesisat Mühendisliği Kongresi, 1055-70.
  • [8] Şentürk, U., Aktakka, S., & Toksoy, M. (2015). Havalandırmada Enerji Geri Kazanımı: Araştırma ve Geliştirme. 12. Ulusal Tesisat Mühendisliği Kongresi, 301-327.
  • [9] Atmaca, M., & Ezgi, C. (2019). Three-dimensional CFD modeling of a steam ejector. Energy Sources, Part A: Recovery, Utilization, and Environmental Effects, 1- 12.
  • [10] Atmaca, M., Girgin, I., & Ezgi, C. (2016). CFD modeling of a diesel evaporator used in fuel cell systems. International Journal of Hydrogen Energy, 41(14), 6004-6012.
  • [11] Atmaca, M., Çetin, B., & Yılmaz, E. (2019). CFD analysis of unmanned aerial vehicles (UAV) moving in flocks. Acta Physica Polonica A, 135(4), 694-696.
  • [12] Kaya, O. (2013). Havadan havaya ısı geri kazanım cihazları için ts en 308 standardına göre test düzeneği tasarımı (Doctoral dissertation, DEÜ Fen Bilimleri Enstitüsü)
APA Savat H, Atmaca M (2021). Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. , 53 - 57. 10.7240/jeps.705202
Chicago Savat Hasan,Atmaca Mustafa Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. (2021): 53 - 57. 10.7240/jeps.705202
MLA Savat Hasan,Atmaca Mustafa Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. , 2021, ss.53 - 57. 10.7240/jeps.705202
AMA Savat H,Atmaca M Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. . 2021; 53 - 57. 10.7240/jeps.705202
Vancouver Savat H,Atmaca M Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. . 2021; 53 - 57. 10.7240/jeps.705202
IEEE Savat H,Atmaca M "Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit." , ss.53 - 57, 2021. 10.7240/jeps.705202
ISNAD Savat, Hasan - Atmaca, Mustafa. "Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit". (2021), 53-57. https://doi.org/10.7240/jeps.705202
APA Savat H, Atmaca M (2021). Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. International journal of advances in engineering and pure sciences (Online), 33(1), 53 - 57. 10.7240/jeps.705202
Chicago Savat Hasan,Atmaca Mustafa Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. International journal of advances in engineering and pure sciences (Online) 33, no.1 (2021): 53 - 57. 10.7240/jeps.705202
MLA Savat Hasan,Atmaca Mustafa Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. International journal of advances in engineering and pure sciences (Online), vol.33, no.1, 2021, ss.53 - 57. 10.7240/jeps.705202
AMA Savat H,Atmaca M Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. International journal of advances in engineering and pure sciences (Online). 2021; 33(1): 53 - 57. 10.7240/jeps.705202
Vancouver Savat H,Atmaca M Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit. International journal of advances in engineering and pure sciences (Online). 2021; 33(1): 53 - 57. 10.7240/jeps.705202
IEEE Savat H,Atmaca M "Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit." International journal of advances in engineering and pure sciences (Online), 33, ss.53 - 57, 2021. 10.7240/jeps.705202
ISNAD Savat, Hasan - Atmaca, Mustafa. "Numerical Examination of Heat Exchanger Shape Effects on ThermalEfficiency In Air to Air Plate Type Heat Recovery Unit". International journal of advances in engineering and pure sciences (Online) 33/1 (2021), 53-57. https://doi.org/10.7240/jeps.705202