Yıl: 2021 Cilt: 32 Sayı: 3 Sayfa Aralığı: 779 - 785 Metin Dili: İngilizce DOI: 10.52312/jdrs.2021.101 İndeks Tarihi: 03-01-2022

Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery

Öz:
The post-traumatic impairment of blood supply of the scaphoidbones’ proximal pole is the subject of controversy in the surgicaltechniques which would heal this fracture. In a surgery performedwith a dorsal approach, the main goal is to make a strong fixationwith a small incision and a good implant without disturbing theblood supply of the bone. To date, complications related to surgicaltreatment of scaphoid proximal pole fractures have been reportedin detail. However, there is no other study which presents headlessscrew failure which placed for the scaphoid proximal pole fracturesurgery. Although implant technologies have been developednowadays, our case report highlights that the endurance of theseimplants has not been carried out in such proximal pole fracturesof the scaphoid, yet. Herein, we present the explanation of a brokenheadless screw which was placed into the proximal pole fractureof scaphoid, avoiding to affect bone stock of the scaphoid surgicaltechnique. We believe that this surgical technique would be helpfulto manage similar difficult situations for orthopedic surgeons.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Olgu Sunumu Erişim Türü: Erişime Açık
  • 1. Acar B, Köse Ö, Turan A, Katı YA, Güler F. Single versus double screw fixation for the treatment of scaphoid waist fractures: Finite element analysis and preliminary clinical results in scaphoid nonunion. Jt Dis Relat Surg 2020;31:73-80.
  • 2. Bushnell BD, McWilliams AD, Messer TM. Complications in dorsal percutaneous cannulated screw fixation of nondisplaced scaphoid waist fractures. J Hand Surg Am 2007;32:827-33.
  • 3. Bürger HK, Windhofer C, Gaggl AJ, Higgins JP. Vascularized medial femoral trochlea osteocartilaginous flap reconstruction of proximal pole scaphoid nonunions. J Hand Surg Am 2013;38:690-700.
  • 4. Kawamura K, Chung KC. Treatment of scaphoid fractures and nonunions. J Hand Surg Am 2008;33:988-97.
  • 5. Luchetti TJ, Rao AJ, Fernandez JJ, Cohen MS, Wysocki RW. Fixation of proximal pole scaphoid nonunion with nonvascularized cancellous autograft. J Hand Surg Eur Vol 2018;43:66-72.
  • 6. Rayhack JM, Linscheid RL, Dobyns JH, Smith JH. Posttraumatic ulnar translation of the carpus. J Hand Surg Am 1987;12:180-9.
  • 7. Rancy SK, Zelken JA, Lipman JD, Wolfe SW. Scaphoid proximal pole fracture following headless screw fixation. J Wrist Surg 2016;5:71-6.
  • 8. Loving VA, Richardson ML. Scaphoid fracture fixation with an Acutrak(®) screw. Radiol Case Rep 2015;1:58-60.
  • 9. Gereli A, Nalbantoglu U, Sener IU, Kocaoglu B, Turkmen M. Comparison of headless screws used in the treatment of proximal nonunion of scaphoid bone. Int Orthop 2011;35:1031-5.
  • 10. Gaston RG, Chadderdon RC. Management of complications of wrist fractures. Hand Clin 2015;31:193-203.
  • 11. McCallister WV, Knight J, Kaliappan R, Trumble TE. Central placement of the screw in simulated fractures of the scaphoid waist: A biomechanical study. J Bone Joint Surg [Am] 2003;85:72-7.
  • 12. Toby EB, Butler TE, McCormack TJ, Jayaraman G. A comparison of fixation screws for the scaphoid during application of cyclical bending loads. J Bone Joint Surg [Am] 1997;79:1190-7.
APA Bezirgan U, acar e, ÖZBEK E (2021). Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. , 779 - 785. 10.52312/jdrs.2021.101
Chicago Bezirgan Uğur,acar erdinç,ÖZBEK Emre Anıl Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. (2021): 779 - 785. 10.52312/jdrs.2021.101
MLA Bezirgan Uğur,acar erdinç,ÖZBEK Emre Anıl Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. , 2021, ss.779 - 785. 10.52312/jdrs.2021.101
AMA Bezirgan U,acar e,ÖZBEK E Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. . 2021; 779 - 785. 10.52312/jdrs.2021.101
Vancouver Bezirgan U,acar e,ÖZBEK E Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. . 2021; 779 - 785. 10.52312/jdrs.2021.101
IEEE Bezirgan U,acar e,ÖZBEK E "Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery." , ss.779 - 785, 2021. 10.52312/jdrs.2021.101
ISNAD Bezirgan, Uğur vd. "Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery". (2021), 779-785. https://doi.org/10.52312/jdrs.2021.101
APA Bezirgan U, acar e, ÖZBEK E (2021). Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. Joint diseases and related surgery, 32(3), 779 - 785. 10.52312/jdrs.2021.101
Chicago Bezirgan Uğur,acar erdinç,ÖZBEK Emre Anıl Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. Joint diseases and related surgery 32, no.3 (2021): 779 - 785. 10.52312/jdrs.2021.101
MLA Bezirgan Uğur,acar erdinç,ÖZBEK Emre Anıl Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. Joint diseases and related surgery, vol.32, no.3, 2021, ss.779 - 785. 10.52312/jdrs.2021.101
AMA Bezirgan U,acar e,ÖZBEK E Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. Joint diseases and related surgery. 2021; 32(3): 779 - 785. 10.52312/jdrs.2021.101
Vancouver Bezirgan U,acar e,ÖZBEK E Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery. Joint diseases and related surgery. 2021; 32(3): 779 - 785. 10.52312/jdrs.2021.101
IEEE Bezirgan U,acar e,ÖZBEK E "Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery." Joint diseases and related surgery, 32, ss.779 - 785, 2021. 10.52312/jdrs.2021.101
ISNAD Bezirgan, Uğur vd. "Can headless screw used in fixation of the scaphoidproximal pole fracture be broken after wrist trauma?An unreported complication of scaphoid surgery". Joint diseases and related surgery 32/3 (2021), 779-785. https://doi.org/10.52312/jdrs.2021.101