Yıl: 2021 Cilt: 14 Sayı: 2 Sayfa Aralığı: 664 - 676 Metin Dili: İngilizce DOI: 10.18185/erzifbed.951061 İndeks Tarihi: 02-03-2022

Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors

Öz:
In this study, all-solid-state chromium (III) selective potentiometric poly(vinylchloride) (PVC) membrane sensors were constructed by using the newly synthesized ionophores called (E)-4-((4–nitrophenylimino) methyl) phenyl acrylate (A1), (E)-4-((4-chlorophenylimino) methyl) phenyl acrylate (A2) and (E)-4-(4- hydroxybenzylideneimino) benzoic acid acrylate (A3). The most suitable membrane composition, which has the best potentiometric characteristics, was examined by using membrane cocktail coated electrodes containing the ionophores, o-nitrophenyloctyl ether (o-NPOE), bis(2-ethylhexyl) sebacate (DOS), dibutyl phthalate (DBP), dioctyl phthalate (DOP) and PVC. In addition, the effect of potassium tetrakis(4-chlorophenyl) borate (KTpClPB) and sodium tetraphenylborate (NaTPB) as ionic additives was investigated to determine optimum membrane composition. The optimum membrane composition was determined as 1.0 % (w/w) A2, 67.0 % (w/w) o-NPOE, and 32.0 % (w/w) PVC. On the condition of pH 3.50 the prepared electrode exhibited a linear response over the concentration range of 1.3×10-7−1.0×10-1 M chromium (III) ion solutions (R2=0.9938) with a sensitivity of 27.1 ± 0.8 mV/ decade, detection limit of 6.3×10-8 M and short response time of ≤10 s. The influences of some widely used cation species over electrode responses were studied. In order to investigate whether the proposed electrode could be used analytically, potentiometric determination of chromium (III) ion was carried out in real samples. The results were statistically compared with the Inductively Coupled PlasmaMass Spectrometry (ICP-MS) method.
Anahtar Kelime:

Akriloil Grup İçeren Schiff Bazlarının Potansiyometrik İyon-Seçici Sensörlerde İyonofor Olarak Kullanımının Araştırılması

Öz:
Bu çalışmada, yeni sentezlenen iyonoforlar kullanılarak tümüyle katı-hal krom (III)-seçici potansiyometrik polivinil klorür (PVC) membran sensör geliştirildi. Bu amaçla yeni sentezlenen akriloil grup içeren (E)-4-(4- Nitro fenilimino) metil fenil akrilat (A1), (E)-4-(4-kloro fenilimino) metil fenil akrilat (A2) ve (E)-4-(4- hidroksibenzil dimino) benzoik asit akrilat (A3) schiff bazları iyonofor olarak kullanıldı. En uygun potansiyometrik özelliklere sahip membran bileşimi farklı oranlarda iyonoforlar (A1, A2 ve A3), plastikleştiriciler (o-nitrofeniloktil eter (o-NPOE)), bis (2-etilheksil) sebekat (DOS), dibutil ftalat (DBP), dioktil ftalat (DOP) ve PVC kullanılarak belirlendi. Ayrıca, optimum membran kompozisyonunu belirlemek için iyonik katkı maddesi olarak potasyum tetrakis(4-klorofenil) borat (KTpClPB) ve sodyum tetrafenilboratın (NaTPB) etkisi araştırıldı. Geliştirilen krom (III)-seçici sensör için % 1,0 A2 bileşiği, % 67,0 (a/a) o-NPOE ve % 32,0 (a/a) PVC oranları en uygun membran bileşimi olarak belirlendi. Geliştirilen krom (III)-seçici sensör pH 3,50’de 1,3×10-7−1,0×10-1 M konsantrasyon aralığında standart krom (III) iyon çözeltisine karşı doğrusal cevap sergiledi (R2= 0,9938). Sensör ile doğrusal çalışma aralığındaki her onkat’lık Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors 665 standart krom (III) konsantrasyon değişiminin ortalaması 27,1 ± 0,8 mV’luk eğim değeri, tekrarlanabilir potansiyeller elde edildi. Geliştirilen tümüyle katı-hal krom (III)-seçici potansiyometrik PVC membran sensörün tayin limiti 6,3×10-8 M ve cevap süresi ≤10 s olarak belirlendi. Yaygın bazı katyon türlerinin geliştirilen sensör üzerindeki girişim etkileri incelendi. Önerilen sensörün analitik olarak kullanılıp kullanılamayacağını araştırmak için, gerçek numunelerde krom (III) iyonunun potansiyometrik tayini gerçekleştirildi. Elde edilen sonuçlar İndüktif Eşleşmiş Plazma-Kütle Spektrometrisi (ICP-MS) metodu ile elde edilen verilerle istatiksel olarak karşılaştırıldı.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • Abbaspour, A., Izadyar, A., (2001). Chromium (III) ion-selective electrode based on 4- dimethylaminoazobenzene, Talanta, 53: 1009-1013.
  • Altunay, N., Yıldırım, E., & Gürkan, R. (2018). Extraction and preconcentration of trace Al and Cr from vegetable samples by vortex-assisted ionic liquid-based dispersive liquid–liquid microextraction prior to atomic absorption spectrometric determination, Food chemistry, 245, 586-594.
  • Awad, A.T., Amr L.S., Gehad, G.M., Tahani, M.B., (2014). Determination of Cr (III) ions in Different Water Samples Using Chromium (III)-sensor based on N-[4-(dimethylamino) benzylidene]-6-nitro-1,3-benzothiazol-2-amine, Int. J. Electrochem. Sci., 9: 4932-4943.
  • Buck, R. P., & Lindner, E. (1994). Recommendations for nomenclature of ion-selective electrodes (IUPAC Recommendations 1994), Pure and Applied Chemistry, 66(12), 2527- 2536.
  • Divrikli, U., Soylak, M., & Elci, L. (2008). Determination of total chromium by flame atomic absorption spectrometry after coprecipitation by cerium (IV) hydroxide, Environmental monitoring and assessment, 138(1), 167-172.
  • Elavarasi, M., Alex, S. A., Chandrasekaran, N., & Mukherjee, A. (2014). Simple fluorescencebased detection of Cr (III) and Cr (VI) using unmodified gold nanoparticles, Analytical Methods, 6(24), 9554-9560.
  • Fekri, M., Khanmohammadi, H., Darvishpour, M., (2011). An electrochemical Cr (III)- Selective Sensor-Based on a Newly Synthesized Ligand and Optimization of Electrode With a Nano Particle, International Journal of electrochemical science, 1679-1685.
  • Gadzekpo, V.P.Y., Christian, G.D., (1984). Determination of selectivity coefficients of ionselective electrodes by a matched potential method, Analytica Chimica Acta, 164: 279-282.
  • Ganjali, M.R., Mizani, F., Salavati-Niasari, M., and Javanbakht, M., (2003). Novel Potentiometric Membrane Sensor for the Determination of Trace Amounts of Chromium (III) Ions, Analytical Sciences, 19:235-238.
  • Ganjali, M.R., Norouzi, P., Faridbod, F., Ghorbani, M., Adib, M., (2006). Highly selective and sensitive chromium (III) membrane sensors based on a new tridentate Schiff’s base, Analytica Chimica Acta, 569: 35-41.
  • Gholivand, M., Sharifpour, F., (2003). Chromium (III) ion-selective electrode based on glyoxal bis(2-hydroxyanil), Talanta,707-713.
  • Gupta, V.K., Jain, A.K., Kumar, P., Agarwal, S., Maheshwari, G., (2006). Chromium (III)- selective sensor based on tri-o-thymotide in PVC matrix, Sensors and Actuators B, 113: 182- 186.
  • Hamilton, E. M., Young, S. D., Bailey, E. H., & Watts, M. J. (2018). Chromium speciation in foodstuffs: A review, Food chemistry, 250, 105-112.
  • Heidari, Z., Masrournia, M., & Khoshnood, R. S. (2016). Fabrication a composite electrode based on MWCNT/Zeolite for potentiometric determination of Cr3+ , Oriental Journal of Chemistry, 32(1), 627.
  • Isildak, I., Yolcu, M., Isildak, O., Demirel, N., Topal, G., & Hosgoren, H. (2004). All-solidstate PVC membrane Ag+-selective electrodes based on diaza-18-crown-6 compounds, Microchimica Acta, 144(1), 177-181.
  • Kaur, V., & Malik, A. K. (2009). Speciation of chromium metal ions by RP-HPLC, Journal of chromatographic science, 47(3), 238-242.
  • Khound, N. J., Phukon, P., & Bhattacharyya, K. G. (2019). Toxic Trace Metals in the Surface Water Sources of Jia–Bharali river basin, North Brahmaputra Plain, India-A Hydrochemical Elucidation, Water Resources, 46(1), 117-127.
  • Kimbrough, D. E., Cohen, Y., Winer, A. M., Creelman, L., & Mabuni, C. (1999). A critical assessment of chromium in the environment, Critical reviews in environmental science and technology, 29(1), 1-46.
  • Kumar, K. G., & Muthuselvi, R. (2006). Spectrophotometric determination of chromium (III) with 2-hydroxybenzaldiminoglycine, Journal of Analytical Chemistry, 61(1), 28-31.
  • Kumar, P., Sharma, H. K., & Shalaan, K. G. (2013). Development of chromium (III) selective potentiometric sensor by using synthesized triazole derivative as an ionophore, Journal of Chemistry, 2013.
  • McIver, D. J., Grizales, A. M., Brownstein, J. S., & Goldfine, A. B. (2015). Risk of type 2 diabetes is lower in US adults taking chromium-containing supplements, The Journal of nutrition, 145(12), 2675-2682.
  • Michalski, R. (2005). Trace level determination of Cr (III)/Cr (VI) in water samples using ion chromatography with UV detection, Journal of liquid chromatography & related technologies, 28(18), 2849-2862.
  • National Research Council (1989). Recommended dietary allowances, 10th ed., National Academy Press, Washington, DC, USA.
  • Pettine, M., Campanella, L., Millero, F.J., (2002). Reduction of hexavalent chromium by H2O2 in acidic solutions, Environmental Science and Technology, 36: 901.
  • Sharma, R.K., and Goel, A., (2005). Development of a Cr(III)-specific potentiometric sensor using Aurin tricarboxylic acid modified silica, Analytica Chimica Acta, 534: 137-142.
  • Sılku, P., Özkınalı, S., Öztürk, Z., Asan, A., & Köse, D. A. (2016). Synthesis of novel Schiff Bases containing acryloyl moiety and the investigation of spectroscopic and electrochemical properties, Journal of Molecular Structure, 1116, 72-83.
  • Sun, Z., & Liang, P. (2008). Determination of Cr (III) and total chromium in water samples by cloud point extraction and flame atomic absorption spectrometry, Microchimica Acta, 162(1-2), 121-125.
  • Wilson, P. B. (2019). Population‐representative analysis of dietary supplementation among Americans with diabetes mellitus, Journal of diabetes, 11(2), 115-121.
  • Zamani, H., Ghadier, R., Ganjali, M.R., (2006). Highly selective and sensitive chromium (III) membrane sensors based on 4-amino-3-hydrazino-6-methyl-1,2,4-triazin-5-one as a new neutral ionophore, Sensors and Actuators B, 119: 41-46.
  • Zhao, Y., & Han, G. (1994). Rapid spectrophotometric determination of chromium (III), Talanta, 41(8), 1247-125.
APA Cubuk O, KIRANLIOĞLU G, ÇOLDUR F, Özkınalı S (2021). Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. , 664 - 676. 10.18185/erzifbed.951061
Chicago Cubuk Osman,KIRANLIOĞLU Gülüzar,ÇOLDUR Fatih,Özkınalı Sevil Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. (2021): 664 - 676. 10.18185/erzifbed.951061
MLA Cubuk Osman,KIRANLIOĞLU Gülüzar,ÇOLDUR Fatih,Özkınalı Sevil Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. , 2021, ss.664 - 676. 10.18185/erzifbed.951061
AMA Cubuk O,KIRANLIOĞLU G,ÇOLDUR F,Özkınalı S Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. . 2021; 664 - 676. 10.18185/erzifbed.951061
Vancouver Cubuk O,KIRANLIOĞLU G,ÇOLDUR F,Özkınalı S Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. . 2021; 664 - 676. 10.18185/erzifbed.951061
IEEE Cubuk O,KIRANLIOĞLU G,ÇOLDUR F,Özkınalı S "Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors." , ss.664 - 676, 2021. 10.18185/erzifbed.951061
ISNAD Cubuk, Osman vd. "Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors". (2021), 664-676. https://doi.org/10.18185/erzifbed.951061
APA Cubuk O, KIRANLIOĞLU G, ÇOLDUR F, Özkınalı S (2021). Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 14(2), 664 - 676. 10.18185/erzifbed.951061
Chicago Cubuk Osman,KIRANLIOĞLU Gülüzar,ÇOLDUR Fatih,Özkınalı Sevil Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi 14, no.2 (2021): 664 - 676. 10.18185/erzifbed.951061
MLA Cubuk Osman,KIRANLIOĞLU Gülüzar,ÇOLDUR Fatih,Özkınalı Sevil Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, vol.14, no.2, 2021, ss.664 - 676. 10.18185/erzifbed.951061
AMA Cubuk O,KIRANLIOĞLU G,ÇOLDUR F,Özkınalı S Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2021; 14(2): 664 - 676. 10.18185/erzifbed.951061
Vancouver Cubuk O,KIRANLIOĞLU G,ÇOLDUR F,Özkınalı S Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2021; 14(2): 664 - 676. 10.18185/erzifbed.951061
IEEE Cubuk O,KIRANLIOĞLU G,ÇOLDUR F,Özkınalı S "Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors." Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 14, ss.664 - 676, 2021. 10.18185/erzifbed.951061
ISNAD Cubuk, Osman vd. "Investigation of Schiff Bases Containing Acryloyl Moiety as Ionophore in Potentiometric Ion-Selective Sensors". Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi 14/2 (2021), 664-676. https://doi.org/10.18185/erzifbed.951061