Yıl: 2021 Cilt: 43 Sayı: 6 Sayfa Aralığı: 554 - 559 Metin Dili: İngilizce DOI: 10.14744/etd.2021.43809 İndeks Tarihi: 19-02-2022

Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure

Öz:
Objective: In this study, we aimed to determine the diagnostic and clinical predictive value of optic nerve sheath diameter (ONSD) measurement in pediatric patients suspected of increased intracranial pressure (IICP) by comparing sonographic ONSD values with radiological parameters and controls. Materials and Methods: In total, 57 pediatric patients with suspected IICP who underwent computed tomography (CT) scans were included in this prospective, observational study; meanwhile, 35 patients were included as controls. Measurements were obtained while the patients were in supine position with their eyes closed, and transbulbar images of both eyes were obtained via a 6–15 MHz linear probe. The CT scans were assessed by a radiologist blinded to sonographic measurements. Glasgow coma scale of patients, service where they were followed, clinical results, CT, and ONSD values were assessed in this study. Results: In the patient group, 26 of the patients were girls (35.4%), and the mean age was 138±56 months (min-max: 82–194 months). Meanwhile, in the control group, 18 of the patients were girls (40.9%), and mean age was 151±45 months (min-max: 106–196 months). As per our findings, 31 patients (54.4%) presented with high-energy trauma. Mean ONSD was 0.5±0.07 cm in the patient group, whereas it was 0.3±0.02 cm in the control group (p=0.008). It was 0.55±0.07 cm in patients with cerebral edema (CE) on CT scan (p=0.013). Based on the presence of CE as detected via CT scan, cut-off value for measurement was determined to be 0.49 cm, with 83.33% sensitivity and 68.42% specificity (AUC: 0.784). Conclusion: Optic nerve sheath measurement can be utilized to immediately support diagnosis and predict follow-up in the assessment of pediatric patients with ICP elevation.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Tayal VS, Neulander M, Norton HJ, Foster T, Saunders T, Blaivas M. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Ann Emerg Med 2007; 49(4): 508–14.
  • 2. Tsung JW, Blaivas M, Cooper A, Levick NR. A rapid noninvasive method of detecting elevated intracranial pressure using bedside ocular ultrasound: application to 3 cases of head trauma in the pediatric emergency department. Pediatr Emerg Care 2005; 21(2): 94–8.
  • 3. Soldatos T, Karakitsos D, Chatzimichail K, Papathanasiou M, Gouliamos A, Karabinis A. Optic nerve sonography in the diagnostic evaluation of adult brain injury. Crit Care 2008; 12(3): R67.
  • 4. Qayyum H, Ramlakhan S. Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency department. Eur J Emerg Med 2013; 20(2): 91–7.
  • 5. Hayreh SS. Optic disc edema in raised intracranial pressure. V. Pathogenesis. Arch Ophthalmol 1977; 95(9): 1553–65.
  • 6. Geeraerts T, Newcombe VF, Coles JP, Abate MG, Perkes IE, Hutchinson PJ, et al. Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure. Crit Care 2008; 12(5): R114.
  • 7. Komut E, Kozacı N, Sönmez BM, Yılmaz F, Komut S, Yıldırım ZN, et al. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of intracranial pressure in ED. Am J Emerg Med 2016; 34(6): 963–7.
  • 8. Steinborn M, Friedmann M, Hahn H, Hapfelmeier A, Macdonald E, Warncke K, et al. Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents. Ultraschall Med 2015; 36(1): 54–8.
  • 9. Soldatos T, Chatzimichail K, Papathanasiou M, Gouliamos A. Optic nerve sonography: a new window for the non-invasive evaluation of intracranial pressure in brain injury. Emerg Med J 2009; 26(9): 630–4.
  • 10. Irazuzta JE, Brown ME, Akhtar J. Bedside optic nerve sheath diameter assessment in the identification of increased intracranial pressure in suspected idiopathic intracranial hypertension. Pediatr Neurol 2016; 54: 35–8.
  • 11. Chacko J. Optic nerve sheath diameter: An ultrasonographic window to view raised intracranial pressure?. Indian J Crit Care Med 2014; 18(11): 707–8.
  • 12. Tekin Orgun L, Atalay HT, Arhan E, Aydın K, Serdaroğlu A. Optic nerve ultrasonography in monitoring treatment efficacy in pediatric idiopathic intracranial hypertension. Child’s Nervous System 2020; 36: 1425–33.
  • 13. Dadı B, Uyar E, Asadow R, İnceköy Girgin F, Ekinci G, Yalındağ Öztürk N. Comparison of ultrasound guided optic nerve sheath diameter measurements with other cranial imaging methods (cranial computed tomography and magnetic resonance ımaging) in pediatric ıntensive care patients. J Pediatr Emerg Intensive Care Med 2019; 6: 1–6.
  • 14. Lin JJ, Chen AE, Lin EE, Hsia SH, Chiang MC, Lin KL. Point-of-care ultrasound of optic nerve sheath diameter to detect intracranial pressure in neurocritically ill children - A narrative review. Biomed J 2020; 43(3): 231–9.
  • 15. Tolu Kendir O, Yılmaz HL, Beğen Doğankoç Ş, Bilen S, Sarı Gökay S, Hergüner OM. Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: a case report. J Emergency Med Case Reports 2019; 10(2): 58–60.
  • 16. Salahuddin N, Mohamed A, Alharbi N, Ansari H, Zaza KJ, Marashly Q, et al. The incidence of increased ICP in ICU patients with non-traumatic coma as diagnosed by ONSD and CT: a prospective cohort study. BMC Anesthesiol 2016; 16(1): 106.
  • 17. Kayadibi Y, Ülgen Tekerek N, Yeşilbaş O, Tekerek S, Üre E, Kayadibi T, et al. Correlation between optic nerve sheath diameter and Rotterdam computer tomography scoring in pediatric brain injury. Ulus Travma Acil Cerrahi Derg 2020; 26(2): 212–21.
  • 18. Hirsch W, Beck R, Behrmann C, Schobess A, Spielmann RP. Reliability of cranial CT versus intracerebral pressure measurement for the evaluation of generalised cerebral oedema in children. Pediatr Radiol 2000; 30(7): 439–43.
  • 19. Del Saz-Saucedo P, Redondo-González O, Mateu-Mateu Á, Huertas-Arroyo R, García-Ruiz R, Botia-Paniagua E. Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension. J Neurol Sci 2016; 361: 122–7.
  • 20. Padayachy LC, Padayachy V, Galal U, Gray R, Fieggen AG. The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children: Part I: repeatability, observer variability and general analysis. Childs Nerv Syst 2016; 32(10): 1769–78.
  • 21. Mehrpour M, Oliaee Torshizi F, Esmaeeli S, Taghipour S, Abdollahi S. Optic nerve sonography in the diagnostic evaluation of pseudopapilledema and raised intracranial pressure: a cross-sectional study. Neurol Res Int 2015; 2015: 146059.
  • 22. Marchese RF, Mistry RD, Scarfone RJ, Chen AE. Identification of optic disc elevation and the crescent sign using point-of-care ocular ultrasound in children. Pediatr Emerg Care 2015; 31(4): 304–7.
  • 23. Chelly J, Deye N, Guichard JP, Vodovar D, Vong L, Jochmans S, et al. The optic nerve sheath diameter as a useful tool for early prediction of outcome after cardiac arrest: A prospective pilot study. Resuscitation 2016; 103: 7–13.
  • 24. Hwan Kim Y, Ho Lee J, Kun Hong C, Won Cho K, Hoon Yeo J, Ju Kang M, et al. Feasibility of optic nerve sheath diameter measured on initial brain computed tomography as an early neurologic outcome predictor after cardiac arrest. Acad Emerg Med 2014; 21(10): 1121–8.
  • 25. Legrand A, Jeanjean P, Delanghe F, Peltier J, Lecat B, Dupont H. Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients. Crit Care 2013; 17(2): R61.
  • 26. Teismann N, Lenaghan P, Nolan R, Stein J, Green A. Point-of-care ocular ultrasound to detect optic disc swelling. Acad Emerg Med 2013; 20(9): 920–5.
APA KENDIR O, YILMAZ H, ballı h, sari s, Ünal İ, Özkaya A (2021). Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. , 554 - 559. 10.14744/etd.2021.43809
Chicago KENDIR OZLEM TOLU,YILMAZ Hayri Levent,ballı hüseyin tuğsan,sari sinem,Ünal İlker,Özkaya Ahmet Kağan Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. (2021): 554 - 559. 10.14744/etd.2021.43809
MLA KENDIR OZLEM TOLU,YILMAZ Hayri Levent,ballı hüseyin tuğsan,sari sinem,Ünal İlker,Özkaya Ahmet Kağan Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. , 2021, ss.554 - 559. 10.14744/etd.2021.43809
AMA KENDIR O,YILMAZ H,ballı h,sari s,Ünal İ,Özkaya A Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. . 2021; 554 - 559. 10.14744/etd.2021.43809
Vancouver KENDIR O,YILMAZ H,ballı h,sari s,Ünal İ,Özkaya A Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. . 2021; 554 - 559. 10.14744/etd.2021.43809
IEEE KENDIR O,YILMAZ H,ballı h,sari s,Ünal İ,Özkaya A "Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure." , ss.554 - 559, 2021. 10.14744/etd.2021.43809
ISNAD KENDIR, OZLEM TOLU vd. "Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure". (2021), 554-559. https://doi.org/10.14744/etd.2021.43809
APA KENDIR O, YILMAZ H, ballı h, sari s, Ünal İ, Özkaya A (2021). Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. Erciyes Medical Journal, 43(6), 554 - 559. 10.14744/etd.2021.43809
Chicago KENDIR OZLEM TOLU,YILMAZ Hayri Levent,ballı hüseyin tuğsan,sari sinem,Ünal İlker,Özkaya Ahmet Kağan Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. Erciyes Medical Journal 43, no.6 (2021): 554 - 559. 10.14744/etd.2021.43809
MLA KENDIR OZLEM TOLU,YILMAZ Hayri Levent,ballı hüseyin tuğsan,sari sinem,Ünal İlker,Özkaya Ahmet Kağan Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. Erciyes Medical Journal, vol.43, no.6, 2021, ss.554 - 559. 10.14744/etd.2021.43809
AMA KENDIR O,YILMAZ H,ballı h,sari s,Ünal İ,Özkaya A Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. Erciyes Medical Journal. 2021; 43(6): 554 - 559. 10.14744/etd.2021.43809
Vancouver KENDIR O,YILMAZ H,ballı h,sari s,Ünal İ,Özkaya A Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure. Erciyes Medical Journal. 2021; 43(6): 554 - 559. 10.14744/etd.2021.43809
IEEE KENDIR O,YILMAZ H,ballı h,sari s,Ünal İ,Özkaya A "Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure." Erciyes Medical Journal, 43, ss.554 - 559, 2021. 10.14744/etd.2021.43809
ISNAD KENDIR, OZLEM TOLU vd. "Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure". Erciyes Medical Journal 43/6 (2021), 554-559. https://doi.org/10.14744/etd.2021.43809