Bronchoscopic Removal of Broken Endotracheal Tube

Öz:
A 75 years old male was admitted to thoracic surgery department with a foreign body in the airway. He was mechanically ventilated in the intensive care unit follow-up period. During weaning, when sedative agents were stopped, the endotracheal tube was damaged by patient bite. Suddenly after extubation, it was observed that only the proximal part of the tube was removed. Despite this, the patient was still conscious and breathing spontaneously. The radiological evaluation revealed that the distal part of the tube was lying through the bronchus intermedius from the subglottic region. We report a case of broken and totally separated endotracheal tube which distal part was removed by rigid bronchoscopy.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Olgu Sunumu Erişim Türü: Erişime Açık
  • 1. Hewlett JC, Rickman OB, Lentz RJ, Prakash UB, Maldonado F. Foreign body aspiration in adult airways: therapeutic approach. J Thorac Dis. 2017;9(9):3398-409. [Crossref] [PubMed] [PMC]
  • 2. Lin L, Lv L, Wang Y, Zha X, Tang F, Liu X. The clinical features of foreign body aspiration into the lower airway in geriatric patients. Clin Interv Aging. 2014;9:1613-8. [Crossref] [PubMed] [PMC]
  • 3. Pugach IZ, Pugach S. Aspiration of extracted tooth under general anesthesia. Case Rep Imag Surg. 2018;1(1):1-2. [Crossref]
  • 4. Dhadge ND. Tooth aspiration following emergency endotracheal intubation. Respir Med Case Rep. 2016;18:85-6. [Crossref] [PubMed] [PMC]
  • 5. Ozgur M. Unexpected desaturation with occlusion due to biting in a deformed endotracheal tube in an ıntensive care patient. Van Tıp Derg. 2016;23(1):142. [Crossref]
  • 6. Duma A, Novak K, Schramm W. Tube-in-tube emergency airway management after a bitten endotracheal tube caused by repetitive transcranial electrical stimulation during spinal cord surgery. Anesthesiology. 2009;111(5): 1155-7. [Crossref] [PubMed]
  • 7. Eisenach JH, Barnes RD. Potential disaster in airway management: a misguided airway exchange catheter via a hole bitten into a univent endotracheal tube. Anesthesiology. 2002;96(5):1266-8. [Crossref] [PubMed]
  • 8. Pawar SC, Kulkarni JA, Jagtap SR, Patil SS. Perioperative crisis management: negative pressure pulmonary edema after violent hiccups at emergence and endotracheal tube occlusion caused by biting. The Internet Journal of Anesthesiology. 2009;25(1):1-5. [Crossref]
  • 9. Jain A, Naithani M, Chaudhary Z, Sharma P. Rare iatrogenic airway foreign body: The rivet from the fulcrum of the McCoy laryngoscope blade. Indian J Anaesth. 2012;56(3):301-2. [Crossref] [PubMed] [PMC]
  • 10. Singh S, Mishra A. Iatrogenic foreign body during extraction. Otolaryngol (Sunnyvale). 2015;5(3):194. [Link]
  • 11. Dhar V, Al-Reefy H, Dilkes M. Case report-- an iatrogenic foreign body in the airway. Int J Surg. 2008;6(6):e46-7. [Crossref] [PubMed]
  • 12. Jain R, Sethi N, Sood J. Loss of integrity of a reinforced endotracheal tube by patient bite. Indian J Anaesth. 2013;57(4):424. [Crossref] [PubMed] [PMC]
  • 13. Sekerci S, Bilgin S, Taştan S. Endotracheal tube breakage during extubation. Eur J Anaesthesiol. 1997;14(2):201-2. [PubMed]
  • 14. Rodriguez R, González H, Carranza A. Intraoral separation of a reinforced endotracheal tube. Anesthesiology. 2000;93(3):908. [Crossref] [PubMed]
  • 15. Kandasamy R, Sivalingam P. Endotracheal tube damage in the presence of bite block. Anesthesiology. 1999;90(2):637. [Crossref] [PubMed]
APA Kış A, AKBUDAK İ (2021). Bronchoscopic Removal of Broken Endotracheal Tube. , 70 - 72. 10.5336/caserep.2020-80382
Chicago Kış Argün,AKBUDAK İLKNUR HATİCE Bronchoscopic Removal of Broken Endotracheal Tube. (2021): 70 - 72. 10.5336/caserep.2020-80382
MLA Kış Argün,AKBUDAK İLKNUR HATİCE Bronchoscopic Removal of Broken Endotracheal Tube. , 2021, ss.70 - 72. 10.5336/caserep.2020-80382
AMA Kış A,AKBUDAK İ Bronchoscopic Removal of Broken Endotracheal Tube. . 2021; 70 - 72. 10.5336/caserep.2020-80382
Vancouver Kış A,AKBUDAK İ Bronchoscopic Removal of Broken Endotracheal Tube. . 2021; 70 - 72. 10.5336/caserep.2020-80382
IEEE Kış A,AKBUDAK İ "Bronchoscopic Removal of Broken Endotracheal Tube." , ss.70 - 72, 2021. 10.5336/caserep.2020-80382
ISNAD Kış, Argün - AKBUDAK, İLKNUR HATİCE. "Bronchoscopic Removal of Broken Endotracheal Tube". (2021), 70-72. https://doi.org/10.5336/caserep.2020-80382
APA Kış A, AKBUDAK İ (2021). Bronchoscopic Removal of Broken Endotracheal Tube. Türkiye Klinikleri Journal of Case Reports, 29(2), 70 - 72. 10.5336/caserep.2020-80382
Chicago Kış Argün,AKBUDAK İLKNUR HATİCE Bronchoscopic Removal of Broken Endotracheal Tube. Türkiye Klinikleri Journal of Case Reports 29, no.2 (2021): 70 - 72. 10.5336/caserep.2020-80382
MLA Kış Argün,AKBUDAK İLKNUR HATİCE Bronchoscopic Removal of Broken Endotracheal Tube. Türkiye Klinikleri Journal of Case Reports, vol.29, no.2, 2021, ss.70 - 72. 10.5336/caserep.2020-80382
AMA Kış A,AKBUDAK İ Bronchoscopic Removal of Broken Endotracheal Tube. Türkiye Klinikleri Journal of Case Reports. 2021; 29(2): 70 - 72. 10.5336/caserep.2020-80382
Vancouver Kış A,AKBUDAK İ Bronchoscopic Removal of Broken Endotracheal Tube. Türkiye Klinikleri Journal of Case Reports. 2021; 29(2): 70 - 72. 10.5336/caserep.2020-80382
IEEE Kış A,AKBUDAK İ "Bronchoscopic Removal of Broken Endotracheal Tube." Türkiye Klinikleri Journal of Case Reports, 29, ss.70 - 72, 2021. 10.5336/caserep.2020-80382
ISNAD Kış, Argün - AKBUDAK, İLKNUR HATİCE. "Bronchoscopic Removal of Broken Endotracheal Tube". Türkiye Klinikleri Journal of Case Reports 29/2 (2021), 70-72. https://doi.org/10.5336/caserep.2020-80382