Yıl: 2021 Cilt: 63 Sayı: 3 Sayfa Aralığı: 434 - 442 Metin Dili: İngilizce DOI: 10.24953/turkjped.2021.03.010 İndeks Tarihi: 24-05-2022

The comparison and diagnostic accuracy of different types of thermometers

Öz:
Background. Fever is one of the leading causes of hospital admissions in children. Although there are many ways to measure body temperature, the optimal method and the anatomic site are still controversial. In this study, we aimed to evaluate the performance of new methods of measuring body temperature and to compare the accuracy, sensitivity and specificity of these methods. Methods. The body temperatures of the patients who were hospitalized as inpatients or who presented to the emergency room as outpatients between November 2014- March 2015 were measured and recorded. Mercury and digital axillary measurements, tympanic, temporal artery and non-contact skin temperatures were measured. Measurements were compared with each other. Results. According to our results temperature tends to increase over time for up to 8 minutes after placement when using axillary thermometers. Non-contact skin thermometers should be used only for follow-up of patients with fever, because of their low sensitivity and low negative predictivity. At the first examination, tympanic thermometers and axillary thermometers may be preferable for the diagnosis of fever. Conclusions. According to our results, using non-contact thermometers seems feasible and logical during the follow-up ofpatients with fever, but not in cases whose exact body temperature should be known. For the first examination of the patient to diagnose fever, tympanic thermometers and axillary thermometers may be preferable. Future studies are warranted to expose the optimum way of measuring body temperature in children
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. El-Radhi AS, Carroll J, Klein N. Clinical Manual of Fever in Children (1st ed) Berlin Heidelberg: Springer-Verlag, 2009.
  • 2. MayA, Bauchner H.Fever phobia: the pediatrician’s contribution. Pediatrics 1992; 90: 851-854.
  • 3. Nierman DM. Core temperature measurement in the intensive care unit. CritCare Med 1991; 19: 818-823.
  • 4. Craig JV, Lancaster GA, Williamson PR, Smyth RL. Temperature measured at the axilla compared with rectum in children and young people: systematic review. BMJ 2000; 320: 1174-1178.
  • 5. Powell KR. Chapter 174: Fever. Kliegman RM, Behrman RE, Jenson HB, Stanton BF. Nelson Textbook of Pediatrics (18th ed) Philedelphia: Elsevier, 2007: 1084-1087.
  • 6. Khorshid L, Eşer İ, Zaybak A, Yapucu U. Comparing mercury‐in‐glass, tympanic and disposable thermometers in measuring body temperature in healthy young people. J Clin Nurs 2005; 14: 496-500.
  • 7. Gardner S. Axillary and rectal temperatures of full term neonates: are they different? Neonatal Netw 1987; 5: 42-43.
  • 8. Chaturvedi D, Vilhekar KY, Chaturvedi P, Bharambe MS. Comparison of axillary temperature with rectal or oral temperature and determination of optimum placement time in children. Indian Pediatr 2004; 41: 600-603.
  • 9. Erdal E, Eşer İ, Demir Ü ve ark.Oral ve aksiller yolla beden sıcaklığı ölçümünde termometrelerin bekletilme sürelerinin incelenmesi. Ege Üniversitesi Hemşirelik Yüksek Okulu Dergisi 1991; 7: 23-28.
  • 10. Greyling G, Viljoen MJ, Joubert G. Axillary temperature compared to tympanic membrane temperature in children. Curationis 2000; 23: 54-61.
  • 11. Latman NS, Hans P, Nicholson L, DeLee Zint S, Lewis K, Shirey A. Evaluation of clinical thermometers for accuracy and reliability. Biomed Instrum Technol 2001; 35: 259-265.
  • 12. Batra P, Goyal S. Comparison of rectal, axillary, tympanic, and temporal artery thermometry in the pediatric emergency room. Pediatric Emerg Care 2013; 29: 63-66.
  • 13. Işler A, Aydin R, Tutar Güven Ş, Günay S. Comparison of temporal artery to mercury and digital temperature measurement in pediatrics. Int Emerg Nurs 2014; 22: 165-168.
  • 14. Siberry GK, Diener-West M, Schappell E, Karron RA. Comparison of temple temperatures with rectal temperatures in children under two years of age. Clin Pediatr (Phila) 2002; 41: 405-414.
  • 15. Hoffman RJ, Etwaru K, Dreisinger N, Khokhar A, Husk G. Comparison of temporal artery thermometry and rectal thermometry in febrile pediatric emergency department patients. Pediatr Emerg Care 2013; 29: 301-304.
  • 16. Greenes DS, Fleisher GR. Accuracy of a noninvasive temporal artery thermometer for use in infants. Arch Pediatr Adolesc Med 2001; 155: 376-381.
  • 17. Can E, Bülbül A, Uslu S, Nuhoğlu A. Yenidoğan yoğun bakım birimindeki hastalarda temassız infrared alın termometresi ile standart termometrelerin karşılaştırılması. Türk Pediatri Arşivi Dergisi 2010; 45: 257-263.
  • 18. Fortuna EL, Carney MM, Macy M, Stanley RM, Younger JG, Bradin SA. Accuracy of non-contact infrared thermometry versus rectal thermometry in young children evaluated in the emergency department for fever. J Emerg Nurs 2010; 36: 101- 104.
  • 19. Paes BF, Vermeulen K, Brohet RM, van der Ploeg T, de Winter JP. Accuracy of tympanic and infrared skin thermometers in children. Arch Dis Child 2010; 95: 974-978.
  • 20. Barton SJ, Gaffney R, Chase T, Rayens MK, Piyabanditkul L. Pediatric temperature measurement and child/parent/nurse preference using three temperature measurement instruments. J Pediatr Nurs 2003; 18: 314-320.
  • 21. Kocoglu H, Goksu S, Isik M, Akturk Z, Bayazit YA. Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting. Int J Pediatr Otorhinolaryngol 2002; 65: 39-43.
  • 22. Lanham DM, Walker B, Klocke E, Jennings M. Accuracy of tympanic temperature readings in children under 6 years of age. Pediatr Nurs 1998; 25: 39-42.
  • 23. El-Radhi A, Patel S. An evaluation of tympanic thermometry in a paediatric emergency department. Emerg Med J 2006; 23: 40-41.
APA ERDEM N, Bedir Demirdag T, TEZER H, CURA YAYLA B, TAPISIZ A, BARAN AKSAKAL F, DERİNÖZ O, OKUR A, Pinarli F, Kocak U, BİDECİ A (2021). The comparison and diagnostic accuracy of different types of thermometers. , 434 - 442. 10.24953/turkjped.2021.03.010
Chicago ERDEM Nurettin,Bedir Demirdag Tugba,TEZER HASAN,CURA YAYLA Burcu Ceylan,TAPISIZ Anıl,BARAN AKSAKAL Fatma Nur,DERİNÖZ Okşan,OKUR Arzu,Pinarli Faruk Guclu,Kocak Ulker,BİDECİ Aysun The comparison and diagnostic accuracy of different types of thermometers. (2021): 434 - 442. 10.24953/turkjped.2021.03.010
MLA ERDEM Nurettin,Bedir Demirdag Tugba,TEZER HASAN,CURA YAYLA Burcu Ceylan,TAPISIZ Anıl,BARAN AKSAKAL Fatma Nur,DERİNÖZ Okşan,OKUR Arzu,Pinarli Faruk Guclu,Kocak Ulker,BİDECİ Aysun The comparison and diagnostic accuracy of different types of thermometers. , 2021, ss.434 - 442. 10.24953/turkjped.2021.03.010
AMA ERDEM N,Bedir Demirdag T,TEZER H,CURA YAYLA B,TAPISIZ A,BARAN AKSAKAL F,DERİNÖZ O,OKUR A,Pinarli F,Kocak U,BİDECİ A The comparison and diagnostic accuracy of different types of thermometers. . 2021; 434 - 442. 10.24953/turkjped.2021.03.010
Vancouver ERDEM N,Bedir Demirdag T,TEZER H,CURA YAYLA B,TAPISIZ A,BARAN AKSAKAL F,DERİNÖZ O,OKUR A,Pinarli F,Kocak U,BİDECİ A The comparison and diagnostic accuracy of different types of thermometers. . 2021; 434 - 442. 10.24953/turkjped.2021.03.010
IEEE ERDEM N,Bedir Demirdag T,TEZER H,CURA YAYLA B,TAPISIZ A,BARAN AKSAKAL F,DERİNÖZ O,OKUR A,Pinarli F,Kocak U,BİDECİ A "The comparison and diagnostic accuracy of different types of thermometers." , ss.434 - 442, 2021. 10.24953/turkjped.2021.03.010
ISNAD ERDEM, Nurettin vd. "The comparison and diagnostic accuracy of different types of thermometers". (2021), 434-442. https://doi.org/10.24953/turkjped.2021.03.010
APA ERDEM N, Bedir Demirdag T, TEZER H, CURA YAYLA B, TAPISIZ A, BARAN AKSAKAL F, DERİNÖZ O, OKUR A, Pinarli F, Kocak U, BİDECİ A (2021). The comparison and diagnostic accuracy of different types of thermometers. Turkish Journal of Pediatrics, 63(3), 434 - 442. 10.24953/turkjped.2021.03.010
Chicago ERDEM Nurettin,Bedir Demirdag Tugba,TEZER HASAN,CURA YAYLA Burcu Ceylan,TAPISIZ Anıl,BARAN AKSAKAL Fatma Nur,DERİNÖZ Okşan,OKUR Arzu,Pinarli Faruk Guclu,Kocak Ulker,BİDECİ Aysun The comparison and diagnostic accuracy of different types of thermometers. Turkish Journal of Pediatrics 63, no.3 (2021): 434 - 442. 10.24953/turkjped.2021.03.010
MLA ERDEM Nurettin,Bedir Demirdag Tugba,TEZER HASAN,CURA YAYLA Burcu Ceylan,TAPISIZ Anıl,BARAN AKSAKAL Fatma Nur,DERİNÖZ Okşan,OKUR Arzu,Pinarli Faruk Guclu,Kocak Ulker,BİDECİ Aysun The comparison and diagnostic accuracy of different types of thermometers. Turkish Journal of Pediatrics, vol.63, no.3, 2021, ss.434 - 442. 10.24953/turkjped.2021.03.010
AMA ERDEM N,Bedir Demirdag T,TEZER H,CURA YAYLA B,TAPISIZ A,BARAN AKSAKAL F,DERİNÖZ O,OKUR A,Pinarli F,Kocak U,BİDECİ A The comparison and diagnostic accuracy of different types of thermometers. Turkish Journal of Pediatrics. 2021; 63(3): 434 - 442. 10.24953/turkjped.2021.03.010
Vancouver ERDEM N,Bedir Demirdag T,TEZER H,CURA YAYLA B,TAPISIZ A,BARAN AKSAKAL F,DERİNÖZ O,OKUR A,Pinarli F,Kocak U,BİDECİ A The comparison and diagnostic accuracy of different types of thermometers. Turkish Journal of Pediatrics. 2021; 63(3): 434 - 442. 10.24953/turkjped.2021.03.010
IEEE ERDEM N,Bedir Demirdag T,TEZER H,CURA YAYLA B,TAPISIZ A,BARAN AKSAKAL F,DERİNÖZ O,OKUR A,Pinarli F,Kocak U,BİDECİ A "The comparison and diagnostic accuracy of different types of thermometers." Turkish Journal of Pediatrics, 63, ss.434 - 442, 2021. 10.24953/turkjped.2021.03.010
ISNAD ERDEM, Nurettin vd. "The comparison and diagnostic accuracy of different types of thermometers". Turkish Journal of Pediatrics 63/3 (2021), 434-442. https://doi.org/10.24953/turkjped.2021.03.010