Yıl: 2022 Cilt: 11 Sayı: 2 Sayfa Aralığı: 869 - 876 Metin Dili: İngilizce DOI: 10.5455/medscience.2021.12.419 İndeks Tarihi: 04-07-2022

2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations

Öz:
We aimed to investigate the positive or negative biological effects of Microwave (MW) exposure on rat femur by morphometric analysis and biomechanical test methods. 22 adult rats were separated into two groups: Group first was used as the control group and the second group of rats was used as a study group which was subjected with 2.45 GHz MW frequency for two hours a day for 21 days. Both groups were sacrificed for morphometric and biomechanical evaluation at the end of 21 days. Morphometric properties were measured using Stereo investigator analyzing system programs. In biomechanical measurements, the femurs of control and exposed group rats were evaluated by intrinsic and extrinsic biomechanics properties. Biomechanical measurements were performed from the left femur mid-diaphysis using a three-point bending test. In the morphometrically measurements, significant differences were statistically found (p<0.05). Biomechanically, there was also a change in extrinsic and intrinsic biomechanics properties between the two groups (p<0.05). This study shows that non-ionizing radiation exposure at a low-level electric field (about 12 V/m, 0.079W/kg) in 2.45 GHz MW radiation might cause morphological and biomechanics alterations on mechanical properties in the rat cortical femur.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Independent Expert Group on Mobile Phones (IEGMP). Mobile Phones and Health (The Stewart Report), Report 1-167. https://www.emf-portal.org/en/ article/11173. 2000
  • 2. International Commission on Non-Ionizing Radiation Protection Exposure to high-frequency electromagnetic fields, biological effects and health consequences (100 kHz –300 GHz)–review of the scientific evidence and health consequences. 2009: https://www.icnirp.org/en/publications/article/ hf-review-2009.html
  • 3. Adair RK. Biophysical Limits on Athermal Effects of RF and Microwave Radiation. Bioelectromagnetics. 2003;24:9-48.
  • 4. Belyaev I. Non-thermal Biological Effects of Microwaves. Microwave Review. 2005;11:13-29.
  • 5. Foster KR, Glaser R. Thermal mechanisms of interaction of radiofrequency energy with biological systems with relevance to exposure guidelines. Health Phys. 2007;92:609-20.
  • 6. Yakymenko I, Tsybulin O, Sidorik E, et al. Oxidative mechanisms of biological activity of low-intensity radiofrequency radiation. Electromagn Biol Med. 2016;35:186-202.
  • 7. Nigg M, Herzog W. Biomechanics of the Musculo-Skeletal System, 2007. 3rd ed. Edited by BENNO, Chichester: John Wiley Sons.
  • 8. Haeussner E, Schmitz C, Von Koch F, Frank Hg. Birth weight correlates with size but not shape of the normal human placenta. Placenta. 2013;34:574-82.
  • 9. Gigliotti JC, Huang L, Ye H, Bajwa A, et al. Ultrasound Prevents Renal Ischemia-Reperfusion Injury by Stimulating the Splenic Cholinergic AntiInflammatory Pathway. J Am Soc Nephrol. 2013;24:1451-60.
  • 10. Boschen K, Ruggiero MJ, Klintsova AY. Neonatal binge alcohol exposure increases microglial activation in the developing rat hippocampus. Neuroscience. 2016;324:355-66.
  • 11. Comelekoglu U, Yalın S, Bagis S,et al. Low-exposure cadmium is more toxic on osteoporotic rat femoral bone: mechanical, biochemical, and histopathological evaluation. Ecotoxicol Environ Saf. 2007;66:267-71.
  • 12. Gurgul S, Erdal N, Yılmaz SN, Yıldız A, Ankaralı H Deterioration of bone quality by long-term magnetic field with extremely low frequency in rats. Bone. 2008;42:74-80.
  • 13. Aslan A, Atay T, Gulle K,et al. Effect of 900 MHz electromagnetic fields emitted from cellular phones on fracture healing: An experimental study on rats. Acta Orthop Traumatol Turc. 2013;47;273-80.
  • 14. Aslan A, Kırdemir V, Kocak A, et al. Influence of 1800 MHz GSM-like Electromagnetic Radiation Exposure on Fracture Healing. Arch Med Res. 2014;45:125-31.
  • 15. Durgun M, Dasdag S, Erbatur S, et al. Effect of 2100 MHz mobile phone radiation on healing of mandibular fractures: an experimental study in rabbits. Biotechnol Biotechnological Equipment. 2016;1:112-20.
  • 16. Currey JD, Foreman J, Laketıd I. Effects of ionizing radiation on the mechanical properties of human bone. J Orthop Res. 1997;1:111–7.
  • 17. Zhou XZ, Zhang G, Dong QR. Low-dose X- irradiation promotes mineralization of fracture callus in a rat model. Arch Orthop Trauma Surg. 2009;129:125–32.
  • 18. Barth HD, Zimmermann EA, Schaible E, et al. Characterization of the effects of X-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone. Biomaterials. 2011;32:8892–904.
  • 19. Demirel C, Kılcıksız S, Gurgul S, et al. N-acetylcysteine ameliorates γ-radiation-induced deterioration of bone quality in the rat femur. J Int Med Res. 2011;39:2393-2401.
  • 20. Soares PB, Soares FCJ, Limirio PHJO, et al. Effect of ionizing radiation after-therapy interval on bone: histomorphometric and biomechanical characteristics. Clin Oral Investig. 2019;23:2785-93.
  • 21. Pacheco R, Stock H. Effects of Radiation on Bone. Curr Osteoporos Rep. 2013;11:299–304.
  • 22. Zhang J, Qiu X, Xi K, et al. Therapeutic ionizing radiation induced bone loss: A review of in vivo and in vitro findings. Connective Tissue Research. 2018;59:509-22.
  • 23. Ciombor DM, Aaron RK. The role of electrical stimulation in bone repair. Foot Ankle Clin. 2005;10:579-93.
  • 24. Haddad JB, Obolensky AG, Shinnick P. The biologic effects and the therapeutic mechanism of action of electric and electromagnetic field stimulation on bone and cartilage: New findings and a review of earlier work. J Altern Complement Med. 2007;13:485-490.
  • 25. Markov MS. Expanding Use of Pulsed Electromagnetic Field Therapies. Electromagn Biol Med. 2007;26:257-74.
  • 26. Turner CH, Burr DB. Basic biomechanical measurements of bone: A Tutorial. Bone. 1993;14:595–608.
  • 27. An, YH, Draughn RA. Mechanical Testing of Bone and the Bone-Implant Interface, 1st Ed., 1999, New York: CRC Press LLC.
  • 28. Bozzini C, MI Olivera, Huygens P, et al. Long-term exposure to hypobaric hypoxia in rat affects femur cross-sectional geometry and bone tissue material properties. Ann Anat. 2009;191:212-7.
  • 29. Turner CH. Biomechanics of bone: determinants of skeletal fragility and bone quality. Osteoporos Int. 2002;13:97-104.
  • 30. International Commision on Non-Ionizing Radiation Protection (2020): ICNIRP guidelines for limiting exposure to electromagnetıc fıelds (100 kHz to 300 GHz).https://www.icnirp.org/cms/upload/publications/ ICNIRPrfgdl2020.pdf.
  • 31. Erkut A, Tumkaya L, Balık MS, et al. The effect of prenatal exposure to 1800 MHz electromagnetic field on calcineurin and bone development in rats. Acta Cir Bras. 2016;31:74-83.
  • 32. Nisbet HO, Akar A, Nisbet C,et al. Effects of electromagnetic field (1.8/0.9 GHz) exposure on growth plate in growing rats. Res Vet Sci. 201;104:24-9.
  • 33. Ergun H, Howland WJ. Postradiation atrophy of mature bone. CRC Crit Rev Diagn Imaging. 1980;12:225-43.
  • 34. Oest ME, Policastro CG, Mann KA, et al. Longitudinal effects of single hindlimb radiation therapy on bone strength and morphology at local and contralateral sites. J Bone Mineral Res. 2018;33:99-112.
  • 35. Green DE, Rubin CT. Consequences of irradiation on bone and marrow phenotypes, and its relation to disruption of hemato of poietic precursors. Bone. 2014;63:87-94.
  • 36. Sams A. The effect of 2000r of X-rays on the acid and alkaline phosphatase of mouse tibiae. Int J Radiat Biol Relat Stud Phys Chem Med. 1966;10:123- 40.
  • 37. Maeda M, Bryant MH, Yamagata M, et al. Effects of irradiation on cortical bone and their time-related changes: a biomechanical and histomorphological study. J Bone Joint Surg Am. 1988;70:392-9.
  • 38. Nyaruba MM, Yamamoto I, Kimura H. Bone fragility induced by X-ray irradiation in relation to cortical bone-mineral content. Acta Radiol. 1998; 39:43–46.
  • 39. Reddy G, Stehno-Bittel L, Hamade S. The biomechanical integrity of bone in experimental diabetes. Diabetes Res Clin Pract. 2001;54:1-8.
  • 40. Burr DB. The contribution of the organic matrix to bone’s material properties. Bone. 2002;31:8-11.
  • 41. Martin RB, Boardman DL. The effects of collagen fiber orientation, porosity, density and mineralization on bovine cortical bone bending properties. J Biomech. 1993;26:1047–54.
  • 42. Ferretti JL, Cointy GR, Capozza RF. Analysis of biomechanical effect on bone and on the bone muscle interactions in small animal models. J Musculoskelet Neuronal Interact. 2001;1:263–74.
  • 43. Ito M, Nishida A, Koga A. Contribution of trabecular and cortical components to the mechanical properties of bone and their regulating parameters. Bone. 2002;31:351-8.
APA AKAR A, Gültiken M, Bolat D, Ormancı N, Korunur Engiz B, SUNAN E, Çömelekoğlu Ü (2022). 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. , 869 - 876. 10.5455/medscience.2021.12.419
Chicago AKAR Ayşegül,Gültiken Murat Erdem,Bolat Durmus,Ormancı Neslihan,Korunur Engiz Begum,SUNAN ERTUGRUL,Çömelekoğlu Ülkü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. (2022): 869 - 876. 10.5455/medscience.2021.12.419
MLA AKAR Ayşegül,Gültiken Murat Erdem,Bolat Durmus,Ormancı Neslihan,Korunur Engiz Begum,SUNAN ERTUGRUL,Çömelekoğlu Ülkü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. , 2022, ss.869 - 876. 10.5455/medscience.2021.12.419
AMA AKAR A,Gültiken M,Bolat D,Ormancı N,Korunur Engiz B,SUNAN E,Çömelekoğlu Ü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. . 2022; 869 - 876. 10.5455/medscience.2021.12.419
Vancouver AKAR A,Gültiken M,Bolat D,Ormancı N,Korunur Engiz B,SUNAN E,Çömelekoğlu Ü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. . 2022; 869 - 876. 10.5455/medscience.2021.12.419
IEEE AKAR A,Gültiken M,Bolat D,Ormancı N,Korunur Engiz B,SUNAN E,Çömelekoğlu Ü "2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations." , ss.869 - 876, 2022. 10.5455/medscience.2021.12.419
ISNAD AKAR, Ayşegül vd. "2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations". (2022), 869-876. https://doi.org/10.5455/medscience.2021.12.419
APA AKAR A, Gültiken M, Bolat D, Ormancı N, Korunur Engiz B, SUNAN E, Çömelekoğlu Ü (2022). 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. Medicine Science, 11(2), 869 - 876. 10.5455/medscience.2021.12.419
Chicago AKAR Ayşegül,Gültiken Murat Erdem,Bolat Durmus,Ormancı Neslihan,Korunur Engiz Begum,SUNAN ERTUGRUL,Çömelekoğlu Ülkü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. Medicine Science 11, no.2 (2022): 869 - 876. 10.5455/medscience.2021.12.419
MLA AKAR Ayşegül,Gültiken Murat Erdem,Bolat Durmus,Ormancı Neslihan,Korunur Engiz Begum,SUNAN ERTUGRUL,Çömelekoğlu Ülkü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. Medicine Science, vol.11, no.2, 2022, ss.869 - 876. 10.5455/medscience.2021.12.419
AMA AKAR A,Gültiken M,Bolat D,Ormancı N,Korunur Engiz B,SUNAN E,Çömelekoğlu Ü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. Medicine Science. 2022; 11(2): 869 - 876. 10.5455/medscience.2021.12.419
Vancouver AKAR A,Gültiken M,Bolat D,Ormancı N,Korunur Engiz B,SUNAN E,Çömelekoğlu Ü 2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations. Medicine Science. 2022; 11(2): 869 - 876. 10.5455/medscience.2021.12.419
IEEE AKAR A,Gültiken M,Bolat D,Ormancı N,Korunur Engiz B,SUNAN E,Çömelekoğlu Ü "2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations." Medicine Science, 11, ss.869 - 876, 2022. 10.5455/medscience.2021.12.419
ISNAD AKAR, Ayşegül vd. "2.45 GHz electromagnetic radiation hazard on the rat cortical femur: morphometric and biomechanical evaluations". Medicine Science 11/2 (2022), 869-876. https://doi.org/10.5455/medscience.2021.12.419